Campbell Scientific NL120 NL120 Ethernet Module - Page 8
Quickstart
View all Campbell Scientific NL120 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
NL120 Ethernet Module 4. Quickstart This section describes the basics of communicating via Ethernet with the NL120. 4.1 Physical Setup CAUTION Always power down the datalogger before installing or removing the NL120 to or from the datalogger. After powering down the datalogger, plug the NL120 into the datalogger peripheral port (see FIGURE 4-1). Attach Ethernet cable to the 10Base-T port. If using the 28033 Surge Protector, connect the other end of the Ethernet cable to the 28033 and connect another Ethernet cable to the other end of the 28033. Restore power to the datalogger. FIGURE 4-1. NL120 attached to a CR1000 4.2 Communicating via Ethernet 4.2.1 Step 1 - Configure Datalogger a. Connect serial cable from PC COM port to datalogger RS-232 port. b. Open Campbell Scientific's Device Configuration Utility. Select the device type of the datalogger (CR1000 or CR3000), the appropriate Serial Port, and baud rate. Connect to the datalogger. c. Under the TCP/IP tab, input the IP Address, Subnet Mask, and IP gateway. These values should be provided by your network administrator. 2