Campbell Scientific PVS4151C PVS4100/4120/4150 Portable Automatic Samplers - Page 13

TABLE 1-2., PVS4150 Sampler Features, Number, Description

Page 13 highlights

Section 1. Product Overview TABLE 1-2. PVS4150 Sampler Features Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Item Signal Panel Volume Control Tube Multi-Function Input Controller Metering Chamber Pinch Valve Side Plug Sample Container Latches Cavity Space for Cooling Pack Quick Connectors Intake Hose Connection LED Indicator Lights Enclosure Intake Hose Sinker. Optional Strainer. Telescoping Handle Side Handles Pressure Gauge Wheels Description Green Light: Integral Battery Charging (AC power connected) Red Light: External Battery Reverse Polarity Toggle Switch: Power On/Off Plug: AC power (coupled with optional signal cable when supplied). This stainless steel tube is raised or lowered manually using the fitting to set the sample volume (see FIGURE 1-3 on page 1-6). This is where sampler is controlled and programmed. This chamber is where the sample liquid is drawn into before dropping into the final container. The rods inside are raised and lowered to the sample volume desired. This valve shuts during sampling, and then releases once desired liquid has entered the chamber. Attached to the side of the door with Velcro. During transport of full sample container, this plug screws into the hole where the discharge tube enters the bottle so that the bottle can be carried upright by its handle. The 2.3 Gal (9L) container that the sample is deposited into is HDPE, or can be upgraded to PP. Container has a side notch with plug for discharge tube to enter. 4 Press-and-Pull Latches provide airtight seal of sampler for transport. Sampler can operate with door open or closed. This space fits one large Zero-Pak cooling pack, to keep sample cooled for 24 hours. Optional connectors for quick connecting and disconnecting. Intake hose is connected to volume control tube in the absence of quick connectors. Green light: Power On/Sampling. Red light: Fault. Hardigg HPX® high performance resin. Enclosure is fully watertight and submersible, depending on options (check with factory). Standard samplers come with 25 Feet of 3/8" ID PVC tube. Keeps the end of the intake tube in the source liquid. Optional strainer can raise collection point above sinker. Retractable handle slides up and down for easy transport by pressing in the small lever on the right side. Four durable soft-grip handles, one on each side, can be folded up or down. Optional gauge on the side of the enclosure (not shown). This is helpful for knowing what stage the sampler is at when sampling with the door closed. Two wheels for rolling on smooth surfaces. 1-5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

Section 1.
Product Overview
1-5
TABLE 1-2.
PVS4150 Sampler Features
Number
Item
Description
1
Signal Panel
Green Light: Integral Battery Charging (AC power connected)
Red Light: External Battery Reverse Polarity
Toggle Switch: Power On/Off
Plug: AC power (coupled with optional signal cable when
supplied).
2
Volume Control Tube
This stainless steel tube is raised or lowered manually using the
fitting to set the sample volume
(see
FIGURE 1-3
on page 1-6).
3
Multi-Function Input Controller
This is where sampler is controlled and programmed.
4
Metering Chamber
This chamber is where the sample liquid is drawn into before
dropping into the final container. The rods inside are raised and
lowered to the sample volume desired.
5
Pinch Valve
This valve shuts during sampling, and then releases once desired
liquid has entered the chamber.
6
Side Plug
Attached to the side of the door with Velcro. During transport of
full sample container, this plug screws into the hole where the
discharge tube enters the bottle so that the bottle can be carried
upright by its handle.
7
Sample Container
The 2.3 Gal (9L) container that the sample is deposited into is
HDPE, or can be upgraded to PP. Container has a side notch with
plug for discharge tube to enter.
8
Latches
4 Press-and-Pull Latches provide airtight seal of sampler for
transport. Sampler can operate with door open or closed.
9
Cavity Space for Cooling Pack
This space fits one large Zero-Pak cooling pack, to keep sample
cooled for 24 hours.
10
Quick Connectors
Optional connectors for quick connecting and disconnecting.
11
Intake Hose Connection
Intake hose is connected to volume control tube in the absence of
quick connectors.
12
LED Indicator Lights
Green light: Power On/Sampling.
Red light: Fault.
13
Enclosure
Hardigg HPX® high performance resin. Enclosure is fully
watertight and submersible, depending on options (check with
factory).
14
Intake Hose
Standard samplers come with 25 Feet of 3/8” ID PVC tube.
15
Sinker. Optional Strainer.
Keeps the end of the intake tube in the source liquid. Optional
strainer can raise collection point above sinker.
16
Telescoping Handle
Retractable handle slides up and down for easy transport by
pressing in the small lever on the right side.
17
Side Handles
Four durable soft-grip handles, one on each side, can be folded
up or down.
18
Pressure Gauge
Optional gauge on the side of the enclosure (not shown). This is
helpful for knowing what stage the sampler is at when sampling
with the door closed.
19
Wheels
Two wheels for rolling on smooth surfaces.