Campbell Scientific SDM SDM-SW8A 8-Channel Switch Closure Input Module - Page 24

Z Loc [:reset Cnt]

Page 24 highlights

Appendix A. Edlog Program Example 10: Do (P86) 1: 1 Call Subroutine 1 11: Z=Z+1 (P32) 1: 25 Z Loc [:RESET CNT] 12: Do (P86) 1: 10 Set high Flag 0 (output) 13: Real Time (P77) 1: 110 Day,Hour-Minute 14: Sample (P70) 1: 1 Reps 2: 25 Loc RESET CNT 15: Do (P86) 1: 21 Set low Flag 1 ********** FIRST SCAN ROUTINE ********** 16: Else (P94) 17: Do (P86) 1: 11 Set high Flag 1 18: End (P95) 19: End (P95) 20: End Table 1 *Table 3 Subroutines ** SUBROUTINE TO MEASURE SDM-SW8A ** 1: Beginning of Subroutine (P85) 1: 1 Subroutine Number 2: SDM-SW8A (P102) 1: 8 Reps 2: 00 Address 3: 0 Channel state(s) function 4: 1 Chan 5: 1 Loc [:state #1 ] 6: 1 Mult 7: 0 Offset A-4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Appendix A.
Edlog Program Example
10:
Do (P86)
1:
1
Call Subroutine 1
11:
Z=Z+1 (P32)
1:
25
Z Loc [:RESET CNT]
12:
Do (P86)
1:
10
Set high Flag 0 (output)
13:
Real Time (P77)
1:
110
Day,Hour-Minute
14:
Sample (P70)
1:
1
Reps
2:
25
Loc RESET CNT
15:
Do (P86)
1:
21
Set low Flag 1
********** FIRST SCAN ROUTINE **********
16:
Else (P94)
17:
Do (P86)
1:
11
Set high Flag 1
18:
End (P95)
19:
End (P95)
20:
End Table 1
*Table 3 Subroutines
** SUBROUTINE TO MEASURE SDM-SW8A **
1:
Beginning of Subroutine (P85)
1:
1
Subroutine Number
2:
SDM-SW8A (P102)
1:
8
Reps
2:
00
Address
3:
0
Channel state(s) function
4:
1
Chan
5:
1
Loc [:state #1 ]
6:
1
Mult
7:
0
Offset
A-4