Campbell Scientific SR50A SR50A Distance Sensor - Page 35
Hourly Data Output
View all Campbell Scientific SR50A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 35 highlights
SR50A Sonic Ranging Sensor 5: Z=SQRT(X) (P39) 1: 6 X Loc [ Mult1 ] 2: 6 Z Loc [ Mult1 ] ;Distance to the Snow Surface is obtained by multiplying the temperature correction ;to the Raw Distance value 6: Z=X*Y (P36) 1: 3 X Loc [ Raw_Dist ] 2: 6 Y Loc [ Mult1 ] 3: 7 Z Loc [ DistToSnw ] ;Set the initial distance from the SR50A to the ground in meters: 7: Z=F x 10^n (P30) 1: 2.5 F 2: 00 n, Exponent of 10 3: 2 Z Loc [ DisToGnd ] 8: Z=X-Y (P35) 1: 2 2: 7 3: 8 X Loc [ DisToGnd ] Y Loc [ DistToSnw ] Z Loc [ SnowDepth ] ;Hourly Data Output 9: If time is (P92) 1: 0 Minutes (Seconds --) into a 2: 60 Interval (same units as above) 3: 1 Set Output Flag High (Flag 0) 10: Set Active Storage Area (P80)^28428 1: 1 Final Storage Area 1 2: 60 Array ID 11: Real Time (P77)^30811 1: 1220 Year,Day,Hour/Minute (midnight = 2400) 12: Sample (P70)^20443 1: 1 Reps 2: 8 Loc [ SnowDepth ] ;The SR50A signal quality value can optionally be stored as well 13: Sample (P70)^22572 1: 1 Reps 2: 4 Loc [ Sig_Qual ] *Table 2 Program 02: 0.0000 Execution Interval (seconds) *Table 3 Subroutines End Program 29