Canon 7215 lv7210_series_exp_cmd.pdf - Page 42

Cr_lampmodecommand, Cr_projhcommand, Sound Status Command, 10.1 Cr_volumecommand, 10.2

Page 42 highlights

EXPAND SERIAL COMMAD FUNCTIONAL SPECIFICATION for LV-5210/7215/7210 9.9.2 CR_LAMPMODECOMMAND COMMAND "CR_LAMPHMODE" [CR] Details Get lamp replacement time information Acceptable "000_%1" [CR] Response "NORMAL" Lamp MODE is NORMAL %1 "ECO"Lamp MODE is silent "AUTO" Lamp MODE is AUTO Unacceptable "?" [CR] 9.9.3 CR_PROJHCOMMAND COMMAND "CR_PROJH" [CR] Details Get total projector running time. (h= hours) Response Acceptable %1 "000_%1" [CR] "0000000"-- "9999999" Unacceptable ?" [CR] 9.10 Sound Status COMMAND 9.10.1 CR_VOLUMECOMMAND COMMAND "CR_VOLUME" [CR] Details Get User Control Volume Acceptable "000_%a" [CR] Response %a "000"-- "063" Unacceptable "?" [CR] 9.10.2 CR_MUTECOMMAND COMMAND "CR_MUTE" [CR] Details Get sound mute setting value Acceptable "000_%a" [CR] Response %a "ON"---- Sound mute is ON "OFF"-- Sound mute is OFF Unacceptable "?" [CR] Page 42

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

EXPAND SERIAL COMMAD FUNCTIONAL SPECIFICATION
for LV-5210/7215/7210
9.9.2
CR_LAMPMODECOMMAND
COMMAND
“CR_LAMPHMODE” [CR]
Details
Get lamp replacement time information
Acceptable
“000_%1” [CR]
%1
“NORMAL” Lamp MODE is NORMAL
“ECO”Lamp MODE is silent
“AUTO” Lamp MODE is AUTO
Response
Unacceptable
“?” [CR]
9.9.3
CR_PROJHCOMMAND
COMMAND
“CR_PROJH” [CR]
Details
Get total projector running time. (h= hours)
Acceptable
“000_%1” [CR]
%1
“0000000”-- ”9999999”
Response
Unacceptable
?” [CR]
9.10
Sound Status COMMAND
9.10.1 CR_VOLUMECOMMAND
COMMAND
“CR_VOLUME” [CR]
Details
Get User Control Volume
Acceptable
“000_%a” [CR]
%a
“000”-- ”063”
Response
Unacceptable
“?” [CR]
9.10.2 CR_MUTECOMMAND
COMMAND
“CR_MUTE” [CR]
Details
Get sound mute setting value
Acceptable
“000_%a” [CR]
%a
“ON”---- Sound mute is ON
“OFF”-- Sound mute is OFF
Response
Unacceptable
“?” [CR]
Page