Basic Serial Functional Specification for LV-5210/7215/7210 6.4 Operation Requirements When the projector's status in this below, functional execution commands are limited. Projector Status Standby Mode Processing Countdown Processing Cooling Down Abnormal Temperature Status Processing Mode Change Processing Power Save・Cooling Down Processing Power Save Available Functional Execution Commands C00:POWER ON Only C00:POWER ON→Terminate processing Countdown C01:POWER OFF C02:POWER OFF→Terminate processing Countdown NONE(does not execute even if receiving a command) NONE(does not execute even if receiving a command) NONE(does not execute even if receiving a command) NONE(does not execute even if receiving a command) C00:POWER ON C01:POWER OFF Other Commands: POWER ON Note) When the status is above, even if the projector receives other command in the above status, the projector returns [ACK] [CR]. 6.5 POWER ON COMMAND COMMAND "C00" [CR] Detail Note) When the status is above, even if the projector receives other command in the above status, the projector returns [ACK] [CR]. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.6 POWER OFF COMMAND (QUICK Power OFF) COMMAND "C01" [CR] Detail Power OFF(Stand By) When Power OFF with ON-OFF button of the projector or the remote control, "Power OFF" will be displayed. However, as soon as this command is sent, Quick Power OFF is executed. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.7 POWER OFF COMMAND COMMAND "C02" [CR] Detail Power OFF(Stand By) When Power OFF with ON-OFF button of the projector or the remote control, "Power OFF" will be displayed. However, as soon as this command is sent, Power OFF is executed. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] Page 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22

Basic Serial Functional Specification for LV-5210/7215/7210
6.4
Operation Requirements
When the projector’s status in this below, functional execution commands are limited.
Projector Status
Available Functional Execution Commands
Standby Mode
C00:POWER ON Only
Processing Countdown
C00:POWER ON
Terminate processing Countdown
C01:POWER OFF
C02:POWER OFF
Terminate processing Countdown
Processing Cooling Down
NONE(does not execute even if receiving a command)
Abnormal Temperature Status
NONE(does not execute even if receiving a command)
Processing Mode Change
NONE(does not execute even if receiving a command)
Processing Power Save
Cooling
Down
NONE(does not execute even if receiving a command)
Processing Power Save
C00:POWER ON
C01:POWER OFF
Other Commands: POWER ON
Note) When the status is above, even if the projector receives other command in the above
status, the projector returns
[ACK] [CR].
6.5 POWER ON COMMAND
COMMAND
“C00” [CR]
Detail
Note) When the status is above, even if the projector receives other command
in the above status, the projector returns
[ACK] [CR].
Acceptable
[ACK] [CR]
Response
Unacceptable
“?” [CR]
6.6 POWER OFF COMMAND (QUICK Power OFF)
COMMAND
“C01” [CR]
Detail
Power OFF(Stand By)
When Power OFF with ON-OFF button of the projector or the remote
control, “Power OFF” will be displayed. However, as soon as this command
is sent, Quick Power OFF is executed.
Acceptable
[ACK] [CR]
Response
Unacceptable
“?” [CR]
6.7 POWER OFF COMMAND
COMMAND
“C02” [CR]
Detail
Power OFF(Stand By)
When Power OFF with ON-OFF button of the projector or the remote
control, “Power OFF” will be displayed. However, as soon as this command
is sent, Power OFF is executed.
Acceptable
[ACK] [CR]
Response
Unacceptable
“?” [CR]
Page