Using your Garage Door Opener, To Open the Door Manually, DISCONNECT THE TROLLEY

Page 34 highlights

Operation Using your Garage Door Opener l The garage door opener can be activated with a wall-mounted door control, remote control, wireless keyless entry, MyQ® Smartphone Control app or MyQ® Garage Door Monitor. When the door is closed and the garage door opener is activated the door will open. If the door senses an obstruction or is interrupted while opening the door will stop. When the door is in any position other than closed and the garage door opener is activated the door will close. If the garage door opener senses an obstruction while closing, the door will reverse. If the obstruction interrupts the sensor beam the garage door opener lights will blink 10 times. If the door is fully open, and the safety reversing sensors are not installed, or are misaligned, the door will not close from a remote control, TTC, or the MyQ® Smartphone Control app. However, you can close the door by holding the button on the door control or the ENTER button on the keyless entry until the door is fully closed. l The garage door opener light bulbs will turn on when the opener is initially plugged in; power is restored after interruption, or when the garage door opener is activated. The lights will turn off automatically after 4-1/2 minutes. The lights will turn on when someone enters through the open garage door and the safety reversing sensor infrared beam is obstructed, see page 35. Use an incandescent A19 light bulb (100W maximum) or for maximum energy efficiency a 26W (100W equivalent) compact fluorescent light (CFL) bulb. NOTE: Do not use halogen, short neck, or specialty light bulbs as these may overheat the end panel or light socket. Do not use LED bulbs as they may reduce the range or performance of your remote controls. To Open the Door Manually To prevent possible SERIOUS INJURY or DEATH from a falling garage door: l If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly. l NEVER use emergency release handle unless garage doorway is clear of persons and obstructions. l NEVER use handle to pull door open or closed. If rope knot becomes untied, you could fall. DISCONNECT THE TROLLEY 1. The door should be fully closed if possible. 2. Pull down on the emergency release handle so the trolley release arm snaps to the vertical position. The door can now be raised and lowered as often as necessary. TO RE-CONNECT THE TROLLEY 1. Pull the emergency release handle toward the garage door opener so the trolley release arm snaps to the horizontal position. The trolley will reconnect on the next UP or DOWN operation, either manually or by using the door control or remote control. 34

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

34
Operation
Using your Garage Door Opener
l
The garage door opener can be activated with a wall-mounted door control, remote control,
wireless keyless entry, MyQ
®
Smartphone Control app or MyQ
®
Garage Door Monitor.When
the door is closed and the garage door opener is activated the door will open. If the door
senses an obstruction or is interrupted while opening the door will stop. When the door is in
any position other than closed and the garage door opener is activated the door will close. If
the garage door opener senses an obstruction while closing, the door will reverse. If the
obstruction interrupts the sensor beam the garage door opener lights will blink 10 times. If the
door is fully open, and the safety reversing sensors are not installed, or are misaligned, the
door will not close from a remote control, TTC, or the MyQ
®
Smartphone Control app.
However, you can close the door by holding the button on the door control or the ENTER
button on the keyless entry until the door is fully closed.
l
The garage door opener light bulbs will turn on when the opener is initially plugged in; power
is restored after interruption, or when the garage door opener is activated. The lights will turn
off automatically after 4-1/2 minutes. The lights will turn on when someone enters through the
open garage door and the safety reversing sensor infrared beam is obstructed, see page 35.
Use an incandescent A19 light bulb (100W maximum) or for maximum energy efficiency a
26W (100W equivalent) compact fluorescent light (CFL) bulb.
NOTE:
Do not use halogen,
short neck, or specialty light bulbs as these may overheat the end panel or light socket. Do not
use LED bulbs as they may reduce the range or performance of your remote controls.
To Open the Door Manually
To prevent possible SERIOUS INJURY or DEATH from a falling garage door:
l
If possible, use emergency release handle to disengage trolley ONLY when garage door is
CLOSED. Weak or broken springs or unbalanced door could result in an open door falling
rapidlyand/or unexpectedly.
l
NEVER use emergency release handle unless garage doorway is clear of persons and
obstructions.
l
NEVER use handle to pull door open or closed. If rope knot becomes untied, you could fall.
DISCONNECT THE TROLLEY
1.
The door should be fully closed if possible.
2.
Pull down on the emergency release handle so the trolley release arm snaps to the vertical
position. The door can now be raised and lowered as often as necessary.
TO RE-CONNECT THE TROLLEY
1.
Pull the emergency release handle toward the garage door opener so the trolley release arm
snaps to the horizontal position. The trolley will reconnect on the next UP or DOWN operation,
either manually or by using the door control or remote control.