Chamberlain PD612EV Manual for PD612EV Manual - Page 22
STEP 11 Wire the door control to the garage door opener, STEP 12 Attach the warning labels
![]() |
View all Chamberlain PD612EV manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
Installation STEP 11 Wire the door control to the garage door opener HARDWARE Insulated Staple (Not Shown) STEP 12 Attach the warning labels 1. Attach the entrapment warning label on the wall near the door control with tacks or staples. 2. Attach the manual release/safety reverse test label in a visible location on the inside of the garage door. 1. Run the white and red/white wire from the door control to the garage door opener. Attach the wire to the wall and ceiling with the staple (not applicable for gang box or pre-wired installations). Do not pierce the wire with the staple as this may cause a short or an open circuit. 2. Strip 7/16 inch (11 mm) of insulation from the end of the wire near the garage door opener. 3. Connect the wire to the red and white terminals on the garage door opener. If your garage is pre- wired make sure you use the same wires that are connected to the door control. To insert or release wires from the terminal, push in the tab with screwdriver tip. 1 2 7/16" (11 mm) Staple 3 RED WHITE WHITE GREY 21