Cisco 3845 Quick Start Guide - Page 14

Grounding the Chassis, Attaching the Cable Management Bracket - parts

Page 14 highlights

Use two screws for each side (supplied with the rack, not with the router). Tip Start the lower pair of screws first, and rest the brackets on the lower screws while you insert the upper pair of screws. Attaching the Cable Management Bracket The optional cable management bracket provides attachment points for organizing and routing cables. Attach the cable management bracket to the left or right rack-mount bracket using the screw provided. You can attach the cable management bracket to either the upper or the lower threaded hole. See Figure 9 for attachment locations. Figure 9 Attaching the Cable Management Bracket to the Cisco 3825 Router NE36SMWD-- 35x GE1 1B0a/s1e0-0T/x1000 17x FastEthernet Ports NME16SW- 15x 7x 15x 7x 35x 17x 34x 16x 33x 15x 32x 14x FastEthernet Ports 31x 13x 30x 12x 29x 11x 28x 10x 27x 9x 8x 14x 6x 13x 5x 12x 4x 11x 3x 10x 2x 9x 1x 0x 8x 0x Ext Pwr -48V GE 11B00a/0s10e0-0T/x EN 26x 8x 25x 17 24x 6x 18x 23x 5x 22x 4x 21x 3x 20x 2x 19x 1x 0x 18x 0x -48V Ext Pwr GE0 11B00a/0s10e0-0T/x EN 117775 Cable management bracket. Either edge may go up. Attach to either side of the chassis. Grounding the Chassis Warning This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024 Warning During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself. Statement 94 You must connect the chassis to a reliable earth ground; the ground wire must be installed in accordance with local electrical safety standards. For NEBS-compliant grounding, use size 6 AWG (13 mm2) copper wire and the ground lug provided in the accessory kit. Note This equipment is suitable for installation in Network Telecommunications Facilities and locations where the NEC applies. The equipment is suitable for installation as part of the Common Bonding Network (CBN). To connect the chassis to a reliable earth ground, perform the following steps: Step 1 Step 2 Strip one end of the ground wire to the length required for the ground lug or terminal (about 0.75 in. [20 mm] for the NEBS ground lug). Crimp the ground wire to the ground lug, using a crimp tool of the appropriate size. 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38

14
Use two screws for each side (supplied with the rack, not with the router).
Tip
Start the lower pair of screws first, and rest the brackets on the lower screws while you insert the upper pair of screws.
Attaching the Cable Management Bracket
The optional cable management bracket provides attachment points for organizing and routing cables. Attach the cable
management bracket to the left or right rack-mount bracket using the screw provided. You can attach the cable management
bracket to either the upper or the lower threaded hole. See Figure 9 for attachment locations.
Figure 9
Attaching the Cable Management Bracket to the Cisco 3825 Router
Grounding the Chassis
Warning
This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of
a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if
you are uncertain that suitable grounding is available.
Statement 1024
Warning
During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly touch the
backplane with your hand or any metal tool, or you could shock yourself.
Statement 94
You must connect the chassis to a reliable earth ground; the ground wire must be installed in accordance with local electrical
safety standards. For NEBS-compliant grounding, use size 6 AWG (13 mm
2
) copper wire and the ground lug provided in the
accessory kit.
Note
This equipment is suitable for installation in Network Telecommunications Facilities and locations where the NEC
applies. The equipment is suitable for installation as part of the Common Bonding Network (CBN).
To connect the chassis to a reliable earth ground, perform the following steps:
Step 1
Strip one end of the ground wire to the length required for the ground lug or terminal (about 0.75 in. [20 mm] for the
NEBS ground lug).
Step 2
Crimp the ground wire to the ground lug, using a crimp tool of the appropriate size.
117775
EN
NMD-
ESW-
36
23x
5x
FastEthernet Ports
22x
4x
21x
3x
20x
2x
19x
1x
18x
0x
29x
11x
28x
10x
27x
9x
26x
8x
25x
17
24x
6x
35x
17x
34x
16x
33x 15x
32x
14x
31x
13x
30x
12x
Ext
Pwr
-48V
0x
18x
GE0
10/100/
1000
Base-Tx
35x
10/100/1000
Base-Tx
GE1
17x
EN
NM-
ESW-
16
15x
7x
14x
6x
13x
5x
FastEthernet Ports
12x
4x
11x
3x
10x
2x
9x
1x
8x
0x
Ext
Pwr
-48V
0x
8x
7x
15x
GE
10/100/
1000
Base-Tx
Cable management bracket.
Either edge may go up. Attach
to either side of the chassis.