Cisco 3845 Quick Start Guide - Page 15

Connect Cables - training

Page 15 highlights

Step 3 Step 4 Attach the ground lug to the chassis as shown in Figure 10 and Figure 11. Tighten the screws to a torque of 8 to 10 in-lb (0.9 to 1.1 N-m). Connect the other end of the ground wire to a suitable grounding point at your site. Figure 10 NEBS-Compliant Chassis Ground Connection on Cisco 3825 Chassis NE36SMWD-- 35x GE1 1B0a/s1e0-0T/x1000 17x 35x 17x 34x 16x 33x 15x 32x 14x 31x 13x 30x 12x FastEthernet Ports 29x 11x 28x 10x 27x 9x 26x 8x 25x 17 24x 6x 18x 23x 5x 22x 4x 21x 3x 20x 2x 19x 1x 0x 18x 0x -48V Ext Pwr GE0 11B00a/0s10e0-0T/x EN 117015 Ground lug attachment Figure 11 NEBS-Compliant Chassis Ground Connection on Cisco 3845 Chassis NME16SW- 15x FastEthernet Ports 8x 7x 15x 7x 14x 6x 13x 5x 12x 4x 11x 3x 10x 2x 9x 1x 0x 8x 0x Ext Pwr -48V GE 11B00a/0s10e0-0T/x EN 122284 Ground lug attachment 5 Connect Cables Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030 Warning The ISDN connection is regarded as a source of voltage that should be inaccessible to user contact. Do not attempt to tamper with or open any public telephone operator (PTO)-provided equipment or connection hardware. Any hardwired connection (other than by a nonremovable, connect-one-time-only plug) must be made only by PTO staff or suitably trained engineers. Statement 23 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38

15
Step 3
Attach the ground lug to the chassis as shown in Figure 10 and Figure 11. Tighten the screws to a torque of 8 to 10
in-lb (0.9 to 1.1 N-m).
Step 4
Connect the other end of the ground wire to a suitable grounding point at your site.
Figure 10
NEBS-Compliant Chassis Ground Connection on Cisco 3825 Chassis
Figure 11
NEBS-Compliant Chassis Ground Connection on Cisco 3845 Chassis
5
Connect Cables
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Warning
The ISDN connection is regarded as a source of voltage that should be inaccessible to user contact. Do not attempt
to tamper with or open any public telephone operator (PTO)-provided equipment or connection hardware. Any
hardwired connection (other than by a nonremovable, connect-one-time-only plug) must be made only by PTO staff
or suitably trained engineers.
Statement 23
117015
EN
NMD-
ESW-
36
23x
5x
FastEthernet Ports
22x
4x
21x
3x
20x
2x
19x
1x
18x
0x
29x
11x
28x
10x
27x
9x
26x
8x
25x
17
24x
6x
35x
17x
34x
16x
33x 15x
32x
14x
31x
13x
30x
12x
Ext
Pwr
-48V
0x
18x
GE0
10/100/
1000
Base-Tx
35x
10/100/1000
Base-Tx
GE1
17x
Ground lug
attachment
EN
NM-
ESW-
16
15x
7x
14x
6x
13x
5x
FastEthernet Ports
12x
4x
11x
3x
10x
2x
9x
1x
8x
0x
Ext
Pwr
-48V
0x
8x
7x
15x
GE
10/100/
1000
Base-Tx
122284
Ground lug
attachment