Page 32 highlights

Step 4 Add the option 43 line using the following syntax: option 43 hex The hex string is assembled by concatenating the TLV values shown below: Type + Length + Value Type is always f1(hex). Length is the number of controller management IP addresses times 4 in hex. Value is the IP address of the controller listed sequentially in hex. For example, suppose that there are two controllers with management interface IP addresses, 10.126.126.2 and 10.127.127.2. The type is f1(hex). The length is 2 * 4 = 8 = 08 (hex). The IP addresses translate to 0a7e7e02 and 0a7f7f02. Assembling the string then yields f1080a7e7e020a7f7f02. The resulting Cisco IOS command added to the DHCP scope is option 43 hex f1080a7e7e020a7f7f02. 11 Access Point Specifications Table 2 lists the technical specifications for 3500 series access points. Table 2 Access Point Specifications Category Specification Dimensions (LxWxD) 8.68 x 8.68 x 1.84 in. (22.04 x 22.04 x 4.67 cm) Weight 1.9 lbs (0.86 kg) Operating temperatures AP3500e: -4 to 131 degrees F (-20 to 55 degrees C) AP3500i: 32 to 104 degrees F (0 to 40 degrees C) Storage temperature -22 to 185 degrees F (-30 to 85 degrees C) Humidity 10% to 90% (noncondensing) Antennas AP3500i: Integrated; AP3500e: External Compliance The 3500 series access point complies with UL 2043 for products installed in a building's environmental air handling spaces, such as above suspended ceilings. 32

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

32
Step 4
Add the option 43 line using the following syntax:
option 43 hex
<
hex string
>
The
hex string
is assembled by concatenating the TLV values shown below:
Type
+
Length
+
Value
Type
is always
f1(hex)
.
Length
is the number of controller management IP addresses times 4
in hex.
Value
is the IP address of the controller listed sequentially in hex.
For example, suppose that there are two controllers with management interface IP addresses,
10.126.126.2 and 10.127.127.2. The type is
f1(hex)
. The length is
2 * 4 = 8 = 08 (hex)
. The IP
addresses translate to
0a7e7e02
and
0a7f7f02.
Assembling the string then yields
f1080a7e7e020a7f7f02
. The resulting Cisco IOS command added to the DHCP scope is
option 43 hex
f1080a7e7e020a7f7f02
.
11
Access Point Specifications
Table 2 lists the technical specifications for 3500 series access points.
Table 2
Access Point Specifications
Category
Specification
Dimensions (LxWxD)
8.68 x 8.68 x 1.84 in. (22.04 x 22.04 x 4.67 cm)
Weight
1.9 lbs (0.86 kg)
Operating temperatures
AP3500e: -4 to 131 degrees F (-20 to 55 degrees C)
AP3500i: 32 to 104 degrees F (0 to 40 degrees C)
Storage temperature
–22 to 185 degrees F (–30 to 85 degrees C)
Humidity
10% to 90% (noncondensing)
Antennas
AP3500i: Integrated; AP3500e: External
Compliance
The 3500 series access point complies with UL 2043 for products installed
in a building’s environmental air handling spaces, such as above suspended
ceilings.