Table 7-2., SFF 240-Watt Power Supply Unit Specifications
UPC - 884420665106
View all Compaq 8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 77 highlights
Power and Signal Distribution Table 7-2 lists the specifications of the 240-watt power supply used in the SFF unit. Table 7-2. SFF 240-Watt Power Supply Unit Specifications Input voltage: 115 VAC 230 VAC Line Frequency Input (AC) Current Requirement (100 VAC rms @ 60 Hz) Output voltage (VDC): +12 Vmain +12 Vcpu +12 Vsb (aux) -12 V AC Range or Min. Current Max. Surge DC Regulation Loading [1] Current Current [2] 90-140 VAC 180-264 VAC 47-63 Hz -- -- -- -- -- -- -- -- 5.5 A rms -- 11.62 to 12.57 11.62 to 12.57 11.06 to 11.74 -10.8 to -13.2 0.5 A 1 A 0.1 A 0 A 14 A 12 A 1.3 A 0.15 A 16 A 16 A 1.5 A 0.5 A Max. Ripple -- --- 120 mV 120 mV 120 mV 120 mV NOTES: Total continuous power should not exceed 240 watts. Total surge power (
Technical Reference Guide
www.hp.com
7-3
Power and Signal Distribution
Table 7-2 lists the specifications of the 240-watt power supply used in the SFF unit.
NOTES:
Total continuous power should not exceed 240 watts. Total surge power (<10 seconds w/duty cycle < 5 %) should not exceed
265 watts.
[1] The minimum current loading figures apply to a PS On start up only.
[2] Maximum surge duration for +12Vcpu is 1 second with 12-volt tolerance +/- 10%.
Table 7-3 lists the specifications for the 320-watt power supply used in the CMT form factor.
NOTES:
Total continuous output power should not exceed 320 watts.
[1] Minimum loading requirements must be met at all times to ensure normal operation and specification compliance.
[2] Maximum surge duration for +12Vcpu is 1 second with 12-volt tolerance +/- 10%.
Table 7-2.
SFF 240-Watt Power Supply Unit Specifications
AC Range or
DC Regulation
Min.
Current
Loading [1]
Max.
Current
Surge
Current [2]
Max.
Ripple
Input voltage:
115 VAC
230 VAC
90–140 VAC
180–264 VAC
--
--
--
--
Line Frequency
47–63 Hz
--
--
--
--
Input (AC) Current Requirement
(100 VAC rms @ 60 Hz)
--
--
5.5 A rms
--
--
Output voltage (VDC):
+12 Vmain
+12 Vcpu
+12 Vsb (aux)
–12 V
11.62 to 12.57
11.62 to 12.57
11.06 to 11.74
–10.8 to –13.2
0.5 A
1 A
0.1 A
0 A
14 A
12 A
1.3 A
0.15 A
16 A
16 A
1.5 A
0.5 A
120 mV
120 mV
120 mV
120 mV
Table 7-3.
CMT 320-Watt Power Supply Unit Specifications
AC Range or
DC Regulation
Min.
Current
Loading [1]
Max.
Current
Surge
Current [2]
Max.
Ripple
Input voltage:
115 VAC
230 VAC
90–140 VAC
180–264 VAC
--
--
--
--
Line Frequency
47–63 Hz
--
--
--
--
Input (AC) Current Requirement
(100 VAC rms @ 60 Hz)
--
--
5.5 A rms
--
--
Output voltage (VDC):
+12 Vmain
+12 Vcpu
+12 Vsb (aux)
–12 V
11.62 to 12.57
11.62 to 12.57
11.06 to 11.74
–10.8 to –13.2
0.5 A
1 A
0.1 A
0 A
16 A
14 A
1.3 A
0.15 A
18 A
18 A
1.5 A
0.5 A
120 mV
120 mV
120 mV
120 mV