DC CHARGING METHOD - BY DC 12V RECHARGING CABLE VIA CIGARETTE LIGHTER PLUG 1. Place the power switch to OFF/RECHARGE position (Position 1). 2. Plug the jack of recharging cord into recharging port on top panel below indicator light. 3. Plug the cigarette plug into 12V car's cigarette l ighter socket. 4. The RED CHARGING LIGHT will i lluminate to confirm charging proceeding. Recharging time is approximately 3 hours with the car engine running. CAUTION: Recharging while car engine is not running may drain car's battery and IS NOT RECOMMENDED. FUSE REPLACEMENT 1. Make sure that the switch is on OFF/RECHARGE position (Position 1) and the 12V OUTPUT socket is disconnected. 2. Insert flat object into slot to open fuse cover on bottom side of unit. 3. Replace new 15A FUSE ONLY, close the cover. SPECIFICATIONS Power Supply Output: DC 12V 15A 180W Max Air Compressor Output: 250 PSI pressure Max Built-in Battery: Sealed Lead-Acid Maintenance Free Rechargeable Battery DC 12V 7AH. Recharging time: AC Charger 13-15 hours 12V Car Battery 3 hours (appox), While driving Weight: 9 lbs 2 oz Dimensions: 12 3/16" L x 7 9/16"W x 4 1/2"H Fuse: 15A Replaceable Page 7