CyberPower PDU81006 User Manual - Page 25
Environmental Monitoring optional, Device Reset, Unattended/Automatic Shutdown, LED Indicators
View all CyberPower PDU81006 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
Operation LED Indicators Indicator Status Tx/Rx Status Green Orange Red Off On (Green) Flashing On LINK Off On Outlet Off Description The PDU status is ok. Warning. Critical. The PDU power is off. The PDU power is on. Receiving/transmitting data packet. Reset finished. Indicates the PDU is connected to the LAN. Indicates the PDU is not connected to the LAN. The outlet is on and providing power. The outlet is off. Environmental Monitoring (optional) CyberPower PDUs along with the environmental sensor (ENVIROSENSOR) provide temperature and humidity monitoring in a server closet and/or datacenter remotely. To connect the PDU with ENVIROSENSOR, use the RJ45 Ethernet Cable included with the ENVIROSENSOR. Plug one end into the Daisy Chain (In)/ ENVIROSENSOR port on the PDU and the other end into the RJ45 port on the ENVIROSENSOR (as shown in figure below). When the PDU correctly connects to the ENVIROSENSOR, users can see the temperature and humidity data via the Web Interface. For further information regarding ENVIROSENSOR configuration, please refer to the Intelligent PDU Web Interface User's Manual. Device Reset • To locally reset all the settings to default, use Reset function in the LCD screen. • To remotely reset all the settings to default, log in to the Web interface, enter the Reset page and apply the function. Unattended/Automatic Shutdown PowerPanel® Business Edition (Client) software automatically initiates a graceful shutdown on the connected computer's operating system. PowerPanel must be installed on every computer or server for which the shutdown is to take place. The computer will receive a message from the PDU, and will perform the shutdown according to the instructions provided, including shut downs at exact times and dates. Step 1. Computer Configuration 1. Install PowerPanel® Business Edition Client on every computer or server that will be part of the shutdown process (Follow the instructions in the PowerPanel® Business Edition User Manual). 2. Configure the settings in PowerPanel® Business Edition Client. See the PowerPanel Business® Edition User Manual for detailed instructions. Step 2. PDU Configuration Verify that the IP address of all computers that will be part of the shutdown process, are included in the Client List on the web interface. 23