D-Link ANT24-1400 Installation Guide - Page 3

ANT24-SP Surge protector, Installation guide, for outdoor antenna-kit

Page 3 highlights

ANT24-SP Surge protector Installation guide for outdoor antenna-kit Step 1 loosen the screw from the surge protector. Option (1) Option (2) Step 2 get a normal conductive copper wire with 2 sides stripped long enough to be conductive, these wires can lead high voltage surges into the grounding. Ground Step 3 find a conductive material nearby the antenna installation sites, connect another end of the wire into position, there are several options: (1) Use a long screw to stick into the ground tightly, connect another wire onto. (2) fix or solder another end of wire onto a steel material/ bar under steel construction, such as wall for buildings, railings or other conductive materials which set up from the ground. Remark: (1) for the ground screw you use, we suggest the longer (deeper into ground) the better performance it has. (2) please use a copper wire with diameter at least from 2.0mm, the thicker the diameter, the higher voltage it can sustain.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23

ANT24-SP Surge protector
Installation guide
for outdoor antenna-kit
Step 1
loosen the screw from the surge protector.
Step 2
get a normal conductive copper wire with 2 sides stripped long enough to be conductive,
these wires can lead high voltage surges into the grounding.
Remark:
(1) for the ground screw you use, we suggest the longer (deeper into ground) the better performance it has.
(2) please use a copper wire with diameter at least from 2.0mm, the thicker the diameter, the higher
voltage it can sustain.
Option (1)
Option (2)
Ground
Step 3
find a conductive material nearby the antenna installation sites, connect another end of the wire
into position, there are several options:
(1) Use a long screw to stick into the ground tightly, connect another wire onto.
(2) fix or solder another end of wire onto a steel material/ bar under steel construction,
such as wall for buildings, railings or other conductive materials which set up from
the ground.