D-Link DGS-3630-28SC User Manual 1 - Page 743
state ERROR_DELAY_SHORT. At least 500 msec, the state POWER_DENIED. At least 500 msec must
View all D-Link DGS-3630-28SC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 743 highlights
DGS-3630 Series Layer 3 Stackable Managed Switch Web UI Reference Guide Trap Name pimInterfaceElection Description to the rate limit specified by pimRPMappingChangeNotificationPeriod. Binding objects: (1) pimGroupMappingPimMode (2) pimGroupMappingPrecedence A pimInterfaceElection notification signifies that a new DR or DF has been elected on a network. This notification is generated whenever the counter pimInterfaceElectionWinCount is incremented, subject to the rate limit specified by pimInterfaceElectionNotificationPeriod. Binding objects: (1) pimInterfaceAddressType (2) pimInterfaceAddress OID 1.3.6.1.2.1.15 7.0.5 PoE Trap Name Description pethMainPowerUsageOnNotificati on This trap indicates PSE Threshold usage indication is on, the usage power is above the threshold. At least 500 msec must elapse between notifications being emitted by the same object instance. Binding objects: (1) pethMainPseConsumptionPower pethMainPowerUsageOffNotificati on This trap indicates PSE Threshold usage indication is off, The usage power is below the threshold. At least 500 msec must elapse between notifications being emitted by the same object instance. Binding objects: (1) pethMainPseConsumptionPower dPoeIfPowerDeniedNotification This Notification indicates if PSE state diagram enters the state POWER_DENIED. At least 500 msec must elapse between notifications being emitted by the same object instance. Binding objects: (1) pethPsePortPowerDeniedCounter dPoeIfPowerOverLoadNotification This trap indicates if PSE state diagram enters the state ERROR_DELAY_OVER. At least 500 msec must elapse between notifications being emitted by the same object instance. Binding objects: (1) pethPsePortOverLoadCounter dPoeIfPowerShortCircuitNotificatio n This trap indicates if PSE state diagram enters the state ERROR_DELAY_SHORT. At least 500 msec must elapse between notifications being emitted by the same object instance. Binding objects: (1) pethPsePortShortCounter dPoeIfPdAliveFailOccurNotificatio n This trap indicates if the PD device has the stop working or no response problem. At least 500 msec must elapse between notifications being emitted by the same object instance. OID 1.3.6.1.2.1.10 5.0.2 1.3.6.1.2.1.10 5.0.3 1.3.6.1.4.1.17 1.14.24.0.1 1.3.6.1.4.1.17 1.14.24.0.2 1.3.6.1.4.1.17 1.14.24.0.3 1.3.6.1.4.1.17 1.14.24.0.4 731