Installation Specifications Cabinet and Countertop Layout warning • Failure to meet or exceed the maximum and minimum dimensions/clearances stated in these instructions may result in a fire hazard. • Follow the countertop manufacturer's instructions regarding the minimum corner radius, use of heat reflective tape, reinforcement of corners, etc. • Carefully check the location where the cooktop will be installed. For best performance, the cooktop should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets. • This appliance is to be used in conjunction with a suitable vent hood or approved Dacor raised vent system. All tolerances +1/16" (+1.6 mm), -0 unless otherwise noted. A 13" max.3 (33.0 cm) Combustible surface to rear 30" min.1, 2 (76.2 cm) 18" min.1, 3 (45.7 cm) See cutout dimensions 1 5/8" min. (4.1 cm) See cutout dimensions 1 Distance to combustible surfaces measured from cooking surface (top of cooktop grate). 2 If installing with an overhead range hood, check the hood specifications for minimum required clearances. 3 This specification does not apply for cabinets located greater than a horizontal distance of 5 1/2" (14.0 cm) from edge of cooktop. Allow 6 7/8" (17.5 cm) from cutout edge. Minimum Required Clearances Around the Cooktop • Allow a minimum 1/4" (6 mm) clearance between the bottom of the cooktop chassis and all combustible surfaces, including the upper edge of a drawer installed below the cooktop. 1/4" (6 mm) mimimum clearance B to combustible surfaces * Allows for clearance between hold down brackets Model DCT305 DCT365 (B) Minimum 29 1/4" (74.3 cm) 35 1/4" (89.5 cm) Under Cabinet Clearances • The gas supply piping, gas shut-off valve and the electrical outlet must be located so that they do not interfere with the cooktop when it is installed. If installing another appliance in the cabinet below, allow for the routing of gas and electrical service behind it. The installation must allow for the following: • Access to the gas shut-off valve and regulator when the unit is installed. • Access to the electrical outlet when the cooktop is in place. The 42" (106.7 cm) power cord must be able to reach the electrical outlet. • Access to the underside of the cooktop for service and inspection purposes. • Clearance inside the cabinet to allow for proper hold down bracket installation. To allow access to the utilities and cooktop bottom, a fixed shelf should not be installed below the cooktop. See the following pages for countertop cutout dimensions. Raised Vent Compatibility Model DCT305 is not compatible with a raised vent. If installing cooktop model DCT365 with a raised vent, install only Dacor raised vent model ERV3615. Installation of any other raised vent model may cause improper operation. Model DCT305 DCT365 (A) Minimum 30" (76.2 cm) 36" (91.4 cm) (A) Recommended 36" (91.4 cm) 42" (106.7 cm) 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

5
Cabinet and Countertop Layout
WARNING
Failure to meet or exceed the maximum and minimum
dimensions/clearances stated in these instructions
may result in a fire hazard.
Follow the countertop manufacturer’s instructions
regarding the minimum corner radius, use of heat
reflective tape, reinforcement of corners, etc.
Carefully check the location where the cooktop will be
installed. For best performance, the cooktop should be
placed away from drafts that may be caused by doors,
windows and heating and air conditioning outlets.
This appliance is to be used in conjunction with a suit-
able vent hood or approved Dacor raised vent system.
Model
(A) Minimum
(A) Recommended
DCT305
30” (76.2 cm)
36” (91.4 cm)
DCT365
36” (91.4 cm)
42” (106.7 cm)
Installation Specifications
Allow a minimum 1/4” (6 mm) clearance between the
bottom of the cooktop chassis and all combustible sur-
faces, including the upper edge of a drawer installed
below the cooktop.
Model
(B) Minimum
DCT305
29 1/4” (74.3 cm)
DCT365
35 1/4” (89.5 cm)
Under Cabinet Clearances
The gas supply piping, gas shut-off valve and the elec-
trical outlet must be located so that they do not inter-
fere with the cooktop when it is installed. If installing
another appliance in the cabinet below, allow for the
routing of gas and electrical service behind it.
The installation must allow for the following:
Access to the gas shut-off valve and regulator when
the unit is installed.
Access to the electrical outlet when the cooktop is in
place. The 42” (106.7 cm) power cord must be able to
reach the electrical outlet.
Access to the underside of the cooktop for service and
inspection purposes.
Clearance inside the cabinet to allow for proper hold
down bracket installation.
To allow access to the utilities and cooktop bottom, a fixed
shelf should not be installed below the cooktop. See the fol-
lowing pages for countertop cutout dimensions.
Raised Vent Compatibility
Model DCT305 is not compatible with a raised vent. If
installing cooktop model DCT365 with a raised vent, install
only Dacor raised vent model ERV3615. Installation of any
other raised vent model may cause improper operation.
1/4” (6 mm)
mimimum clearance
to combustible
surfaces
B
* Allows for clearance between hold down brackets
13” max.
3
(33.0 cm)
3
This specification does not apply for
cabinets located
greater than a horizontal distance of
5 1/2” (14.0 cm) from
edge of cooktop. Allow 6 7/8” (17.5 cm)
from cutout edge.
A
1 5/8” min.
(4.1 cm)
Combustible
surface to rear
30” min.
1, 2
(76.2 cm)
See cutout
dimensions
See cutout
dimensions
2
If installing with an overhead range hood, check the hood
specifications for minimum required clearances.
1
Distance to combustible surfaces measured from cooking
surface (top of cooktop grate).
18” min.
1, 3
(45.7 cm)
All tolerances +1/16” (+1.6 mm), -0
unless otherwise noted.
Minimum Required Clearances Around the Cooktop