Dacor DR30EI Planning Guides - Page 3

Distinctive, Electric Ranges - dr30eifs

Page 3 highlights

DR30ES, DR30EFS, DR30EIS, DR30EIFS Document # PG05-008 Distinctive 30" Wide Electric Ranges Revised 10/30/12 Page 3/4 PLANNING GUIDE 10" (25.4 cm) 10" (25.4 cm) Electrical Specifications ELECTRICAL REQUIREMENTS Electrical Circuit Required Total Connected Load** 240 Vac 60 Hz, 4 wire*, 50 Amp. 11.94kW (49.75 Amp.) *Two 120 Vac hot (L1 and L2), one neutral (N1) and one ground. **This information above is for reference only. If the above data does not agree with the product data label, use the data on the product data label. IMPORTANT: Freestanding ranges equipped for use in Canada come pre-wired with a 4 wire appliance cord and NEMA 14-50P plug. Do not modify the factory wiring. The plug is designed to plug directly into a NEMA 14-50R electrical receptacle installed by a licensed electrician according to the above specifications. 12" (30.5 cm) 2 1/2" (6.4 cm) 3 1/2" (8.9 cm) 1" (2.5 cm) utility clearance behind range NEMA 14-50P Plug NEMA 14-50R Receptacle Self-Rimming Installation Cutout Options (Models DR30EIS and DR30EIFS Only) All tolerances +1/16" (+1.6 mm), -0 unless otherwise noted. Countertop height: 34 3/4" (88.3 cm) min. 36 7/8" (93.7 cm) max. Countertop thickness: 1 5/8" (4.1 cm) max. 10" min. (25.4 cm) to any combustibles above counter both sides Rear wall or countertop edge 3/8" min. (9.5 mm) countertop overhang 10" min. (25.4 cm) to any combustibles above counter both sides Rear wall or countertop edge 3/8" min. (9.5 mm) countertop overhang 24 1/2" (62.2 cm) max. Countertop front 29 1/4" (74.3 cm) countertop opening 30 1/16" (76.2 cm) cabinet opening below countertop Notch countertop to width of cabinets Cabinet face below countertop 19 7/8" 19 7/8" (50.5 cm) (50.5 cm) to 22 7/8" (58.1 cm) 24 1/2" (62.2 cm) max. Countertop front 29 1/4" (74.3 cm) countertop opening 30 1/16" (76.2 cm)* cabinet opening below countertop Notch countertop to width of cabinets Cabinet face below countertop 22 7/8" (58.1 cm) Top View - Slide-In, Self-Rimming Installation, 3" Side Panels Installed Top View - Slide-In, Self-Rimming Installation, 3" Side Panels Removed * To create a "built-in look" on the front of the cabinet, this dimension may be changed to 29 1/4" (74.3 cm), with the width at the notches remaining 30 1/16". This configuration is only for models DR30EIS and DR30EIFS with side panels behind door removed. All specifications subject to change without notice. www.dacor.com Phone: (800) 793-0093

  • 1
  • 2
  • 3
  • 4

All specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
PLANNING
GUIDE
DR30ES, DR30EFS, DR30EIS, DR30EIFS
Distinctive
30” Wide
Electric Ranges
Document # PG05-008
Revised 10/30/12
Page 3/4
All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted.
* To create a “built-in look” on the front of the cabinet, this dimension may be changed to
29 1/4” (74.3 cm), with the width at the notches remaining 30 1/16”. This configuration is
only for models DR30EIS and DR30EIFS with side panels behind door removed.
Countertop height: 34 3/4” (88.3 cm) min.
36 7/8” (93.7 cm) max.
Countertop thickness: 1 5/8” (4.1 cm) max.
TOP VIEW - SLIDE-IN, SELF-RIMMING INSTALLATION, 3”
SIDE PANELS REMOVED
TOP VIEW - SLIDE-IN, SELF-RIMMING INSTALLATION, 3”
SIDE PANELS INSTALLED
Self-Rimming Installation Cutout Options (Models DR30EIS and DR30EIFS Only)
Electrical Specifications
Rear wall or
countertop edge
countertop opening
29 1/4” (74.3 cm)
30 1/16” (76.2 cm)
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
to width of cabinets
3/8” min. (9.5 mm)
countertop overhang
10” min. (25.4 cm)
to any combustibles
above counter both sides
19 7/8”
(50.5 cm)
to
22 7/8”
(58.1 cm)
19 7/8”
(50.5 cm)
24 1/2”
(62.2 cm)
max.
Countertop front
Rear wall or
countertop edge
countertop opening
29 1/4” (74.3 cm)
30 1/16” (76.2 cm)*
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
to width of cabinets
3/8” min. (9.5 mm)
countertop overhang
10” min. (25.4 cm)
to any combustibles
above counter both sides
22 7/8”
(58.1 cm)
24 1/2”
(62.2 cm)
max.
Countertop front
10” (25.4 cm)
10” (25.4 cm)
12” (30.5 cm)
2 1/2”
(6.4 cm)
3 1/2”
(8.9 cm)
1” (2.5 cm)
UTILITY CLEARANCE BEHIND RANGE
NEMA 14-50P PLUG
NEMA 14-50R RECEPTACLE
ELECTRICAL REQUIREMENTS
Electrical Circuit
Required
Total Connected
Load**
240 Vac 60 Hz, 4 wire*,
50 Amp.
11.94kW (49.75 Amp.)
*Two 120 Vac hot (L1 and L2), one neutral (N1) and one ground.
**This information above is for reference only. If the above data
does not agree with the product data label, use the data on the
product data label.
IMPORTANT:
Freestanding ranges equipped for use in Canada
come pre-wired with a 4 wire appliance cord and NEMA 14-50P
plug. Do not modify the factory wiring. The plug is designed to
plug directly into a NEMA 14-50R electrical receptacle installed
by a licensed electrician according to the above specifications.