Dacor DR30G Planning Guides - Page 2
Planning, Guide - dr30gis
View all Dacor DR30G manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
DR30GS, DR30GFS, DR30GIS, DR3GIFS Document # PG05-007 Distinctive 30" Wide All Gas Ranges Revised 09/13/12 Page 2/4 PLANNING GUIDE All tolerances +1/16" (+1.6 mm), -0 unless otherwise noted. B 13" (33.0 cm) max.4 Back wall immediately behind range6 Note 1 14" (35.6 cm) A min.4 Note 2 Top of finished counter Suggested location of utilities3 Note 5 ■■ Failure to meet or exceed the maximum and minimum dimensions/clearances stated may result in a fire hazard. ■■ The range should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets. ■■ To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above surface units should be avoided. If cabinet storage space is to be provided directly above the range, the risk of personal injury may be reduced by installing a range hood. ■■ In all instances, installation of a range hood is highly recommended. The hood should project horizontally a minimum of five (5) inches beyond the face of the cabinets. See the range hood specifications for minimum clearances. ■■ The range may be installed flush to the rear wall. See diagram and notes for rear wall surface requirements. It is not necessary to install noncombustible materials behind the range below the countertop height. ■■ Any openings in the wall behind the appliance or in the floor underneath it must be sealed. C A* B C 30" min. (76.2 cm) 36" (91.4 cm) recommended 30" (76.2 cm) min. 37" (94.0 cm) max. * See the cutout dimensions on following page for self-rimming installations. Freestanding Installation Cabinet Cutout Dimensions - Models DR30GS, DR30GFS, DR30GIS and DR30GIFS 1 30" (76.2 cm) min. vertical clearance from top of range grates to bottom of uncovered wood or metal cabinet. 24" (61 cm) min. clearance if bottom of wood or metal cabinets are protected by not less than 1/4" (0.6 cm) flame retardant millboard covered with no less than No. 28 MSG sheet steel 0.015" (0.04 cm) stainless steel, or 0.024" (0.06 cm) aluminum or 0.020" (0.05cm) copper. 30" (76.2 cm) min. clearance between top of range grates and bottom of unprotected wood or metal cabinet. If installing range hood, check the hood specifications for minimum required clearances. 2 Cabinet/countertop depth is at discretion of customer but cabinet face SHALL NOT protrude further than rear of front panel. See Product Dimensions. 3 Consult local code and following pages for requirements. 4 This specification not applicable for cabinets more than a horizontal distance of 10" (25.4 cm) from edge of range. 5 10" (25.4 cm) min. to combustible sidewalls above range (both sides). 6 Non-combustible surface required for models DR30GIS and DR30GIFS up to vertical distance specified in note 1 or range hood, whichever is lower. Noncombustible surface recommended, but not required, for models DR30GS and DR30GFS. All specifications subject to change without notice. www.dacor.com Phone: (800) 793-0093