Dacor DR30G Planning Guides - Page 4
Back Of Range, Utility Clearance Behind Range - dr30gs
View all Dacor DR30G manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
DR30GS, DR30GFS, DR30GIS, DR3GIFS Document # PG05-007 Distinctive 30" Wide All Gas Ranges Revised 09/13/12 Page 4/4 PLANNING GUIDE 10" (25.4 cm) 10" (25.4 cm) 12" (30.5 cm) 12 1/4" (31.1 cm) to 14 1/4" (36.2 cm) 6' (183 cm) long 2 1/2" (6.4 cm) 3 1/2" (8.9 cm) 1" (2.5 cm) utility clearance behind range 4 1/4" (10.8 cm) back of range ELECTRICAL REQUIREMENTS Electrical Circuit Required Total Connected Load 120 Vac, 60 Hz, 15 Amps., dedicated, grounded 4.0 Amps. @ 120 Vac, 60 Hz Gas Type Natural LP GAS SUPPLY PRESSURE REQUIREMENTS Manifold Pressure* (WC) Min. Gas Supply Pressure (WC) Max. Input Pressure 5" 6" 1/2 psi 10" 11" 1/2 psi IMPORTANT: The information above is for reference only. If the above data does not agree with the product data label, use the data on the product data label. The gas inlet on the regulator accommodates a 1/2" NPT gas line connection. The range can also accommodate a 3/4" NPT gas line connection by removing the 1/2" to 3/4" adapter on the regulator inlet. All specifications subject to change without notice. www.dacor.com Phone: (800) 793-0093