Dacor EH3012 Installation Instructions - Page 8

Planning the Installation

Page 8 highlights

Planning the Installation warning Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. Cabinet Layout warning To reduce the risk of personal injury caused by reaching over a hot appliance, cabinet storage space located directly above the range should be avoided. E Electrical access 25" Min. (63.5 cm) MINIMUM CABINET WIDTH Models E EH3012, EH3018, MH3012, MH3018 EH3612, EH3618, MH3612, MH3618 30" (76.2 cm) 36" (91.5 cm) EH4212, EH4218 42" (106.7 cm) EH4812, EH4818, MH4812, MH4818 EH5418 48" (121.9 cm) 54" (137.2 cm) All tolerances: +1/16", -0, unless otherwise stated important See the diagram for minimum installed distance from the hood to the cooktop surface. The minimum specified distance may be higher for the particular range or cooktop in use. Check the manufacturers specifications for the cooktop or range. • Carefully check the location where the hood is to be installed. The hood should be placed for convenient access. Make certain that electric power can be provided in the selected location. The hood must be centered horizontally over the cooktop/range. • The hood model selected must be as wide as the cooktop surface or wider. • Plan the installation so that all minimum dimensions are met or exceeded. Dimensions shown provide minimum clearances, unless otherwise noted. • All contact surfaces between the hood and any cabinets or walls must be solid and at right angles. • Install the range hood and cooking appliance(s) so that they can be removed if service is required. Power Supply warning The electric service to the range hood should be installed only by a licensed electrician. It is the owner's responsibility to ensure that the electrical connection of this appliance is performed by a qualified electrician. The electrical installation, including minimum supply wire size and grounding, must be in accordance with the National Electric code ANSI/NFPA* (or latest revision) and local codes and ordinances. *A copy of this standard may be obtained from: National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101 • The ground terminal on the hood must be connected to a grounded, metallic, permanent wiring system or grounding conductor installed by a licensed electrician. • Do not ground the appliance or appliance wiring to a gas pipeline or to the neutral (white) power supply wire. • Do not install a fuse in the neutral or ground circuit. • Connect the hood directly to an electrical junction box. Hard-wire the hood according to local code directly to a dedicated three wire grounded, single phase circuit rated at 120 Vac 60 Hz, 15 Amp. 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

6
Planning the Installation
Cabinet Layout
WARNING
To reduce the risk of personal injury caused by reaching
over a hot appliance, cabinet storage space located
directly above the range should be avoided.
MINIMUM CABINET WIDTH
Models
E
EH3012, EH3018, MH3012, MH3018
30” (76.2 cm)
EH3612, EH3618, MH3612, MH3618
36” (91.5 cm)
EH4212, EH4218
42” (106.7 cm)
EH4812, EH4818, MH4812, MH4818
48” (121.9 cm)
EH5418
54” (137.2 cm)
All tolerances: +1/16”, -0, unless otherwise stated
WARNING
Observe all governing codes and ordinances during planning and installation. Contact your local building department for
further information.
IMPORTANT
See the diagram for minimum installed distance from
the hood to the cooktop surface. The minimum specified
distance may be higher for the particular range or
cooktop in use. Check the manufacturers specifications
for the cooktop or range.
Carefully check the location where the hood is to be
installed. The hood should be placed for convenient
access. Make certain that electric power can be provid-
ed in the selected location. The hood must be centered
horizontally over the cooktop/range.
The hood model selected must be as wide as the
cooktop surface or wider.
Plan the installation so that all minimum dimensions are
met or exceeded. Dimensions shown provide minimum
clearances, unless otherwise noted.
All contact surfaces between the hood and any cabi-
nets or walls must be solid and at right angles.
Install the range hood and cooking appliance(s) so that
they can be removed if service is required.
Power Supply
WARNING
The electric service to the range hood should be installed
only by a licensed electrician.
It is the owner’s responsibility to ensure that the electrical
connection of this appliance is performed by a qualified
electrician. The electrical installation, including minimum
supply wire size and grounding, must be in accordance
with the National Electric code ANSI/NFPA* (or latest revi-
sion) and local codes and ordinances.
*A copy of this standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
The ground terminal on the hood must be connected
to a grounded, metallic, permanent wiring system or
grounding conductor installed by a licensed electrician.
Do not ground the appliance or appliance wiring to a
gas pipeline or to the neutral (white) power supply wire.
Do not install a fuse in the neutral or ground circuit.
Connect the hood directly to an electrical junction box.
Hard-wire the hood according to local code directly to
a dedicated three wire grounded, single phase circuit
rated at 120 Vac 60 Hz, 15 Amp.
E
25” Min.
(63.5 cm)
Electrical
access