Document # PG05-003 ER30D, ER30DSR Epicure® Ranges Revised 02/03/11 Page 2/3 PLANNING GUIDE Product tolerances: ±1/16" (±1.6 mm) unless otherwise stated GAS - ELECTRICAL ACCESS DIMENSIONS A B C D E 4 7/8" (124 mm) 21 3/4" (552 mm) 8 5/8" (219 mm) 10 3/16" (259 mm) 7/8"* (22 mm) B D Gas inlet Range electrical access, cover removed A C 7/8" (22 mm) Dia. electrical connection hole in bottom* back of range Cabinet tolerances: +1/16", (+1.6 mm) -0 F 13" (330 mm) Max.4 * The hole size can be increased to 1 1/8" by removing the conduit bracket inside the range electrical access box. Gas and Electrical Service ■■ The shaded area (diagram bottom left) denotes the location of the gas inlet and the electrical junction box/receptacle. This is the recommended location. For replacement purposes, the location of the existing utilities may be utilized provided they do not interfere with the sides or rear of the range. Check local building codes for permissible gas valve and electrical locations. ■■ An external manual shut-off valve must be installed between the gas inlet and the range, for the purpose of turning on or shutting off gas to the appliance. The installation must allow for the following: ■■ Access to the gas shut-off valve when the unit is installed. ■■ Access to the remote circuit breaker panel/fuse box, when the range is in place. ■■ The gas supply piping and shut-off valve, and the electrical junction box/receptacle must be located so they do not interfere with the range when it is installed. ■■ The junction box and gas shut off valve must be located so that the range can be pulled out for service while the appliance remains connected. GAS SUPPLY PRESSURE REQUIREMENTS* Gas Type Manifold Pressure Minimum Gas Supply Pressure Natural Gas 5" Water Column 6" Water Column Petroleum (LP) 10" Water Column 11" Water Column * Maximum input gas supply pressure for all models is 1/2 p.s.i. 18" (457 mm) Min.1, 4 Non-combustible surface along back wall recommended 30" (762 mm) Min.1 G 10" (254 mm) Min. to combustible side walls above the range (both sides) Note 2 36 1/2" (927 mm) Max. Suggested location of utilities 3 1 Vertical to combustible surface from range grate level; if installing an overhead vent hood, also check the hood specifications for minimum required clearances. 2 Cabinet/countertop depth is at discretion of customer but cabinet face MUST NOT protrude further than rear of front panel, see product dimensions. 3 Consult local code for exact location requirements. 4 Not applicable for cabinets more than a horizontal distance of 10" (254 mm) from the edge of the range. CUT-OUT DIMENSIONS F G 36" (914 mm)* 30" (762 mm)** 30 1/16" (916 mm)* * Recommended ** Minimum Cabinet cutout dimensions MODELS ER30D AND ER3OD-C NOTE: See following page for countertop/cabinet cutout dimensions for self-rimming installations Specifications subject to change without notice. www.Dacor.com Phone: (800) 7935-0.8093

  • 1
  • 2
  • 3

PLANNING
GUIDE
Specifications subject to change without notice.
Phone: (800) 793-0093
www.Dacor.com
Epicure
®
Ranges
ER30D, ER30DSR
Note 2
F
G
2
Cabinet/countertop depth is at discretion of customer but
cabinet face MUST NOT protrude further than rear of front
panel, see product dimensions.
3
Consult local code for exact location requirements.
1
Vertical to combustible surface from range grate level; if
installing an overhead vent hood, also check the hood
specifications for minimum required clearances.
Non-combustible
surface along
back wall
recommended
10” (254 mm) Min.
to combustible side
walls above the range
(both sides)
30” (762 mm)
Min.
1
36 1/2”
(927 mm)
Max.
13” (330 mm)
Max.
4
18” (457 mm)
Min.
1, 4
Suggested
location of
utilities
3
4
Not applicable for cabinets more than a horizontal
distance of 10” (254 mm) from the edge of the range.
CUT-OUT DIMENSIONS
F
G
36” (914 mm)*
30” (762 mm)**
30 1/16” (916 mm)*
* Recommended
** Minimum
Gas and Electrical Service
The shaded area (diagram bottom left) denotes the location of
the gas inlet and the electrical junction box/receptacle. This is the
recommended location. For replacement purposes, the location of the
existing utilities may be utilized provided they do not interfere with the
sides or rear of the range. Check local building codes for permissible
gas valve and electrical locations.
An external manual shut-off valve must be installed between the gas
inlet and the range, for the purpose of turning on or shutting off gas to
the appliance.
The installation must allow for the following:
Access to the gas shut-off valve when the unit is installed.
Access to the remote circuit breaker panel/fuse box, when the range
is in place.
The gas supply piping and shut-off valve, and the electrical junction
box/receptacle must be located so they do not interfere with the range
when it is installed.
The junction box and gas shut off valve must be located so that
the range can be pulled out for service while the appliance remains
connected.
CABINET CUTOUT DIMENSIONS
MODELS ER30D AND ER3OD-C
NOTE:
See following page for countertop/cabinet cutout
dimensions for self-rimming installations
Cabinet tolerances:
+1/16”, (+1.6 mm) -0
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type
Manifold Pressure
Minimum Gas Supply
Pressure
Natural Gas
5” Water Column
6” Water Column
Petroleum (LP)
10” Water Column
11” Water Column
* Maximum input gas supply pressure for all models is 1/2 p.s.i.
GAS - ELECTRICAL ACCESS DIMENSIONS
A
B
C
D
E
4 7/8”
(124 mm)
21 3/4”
(552 mm)
8 5/8”
(219 mm)
10 3/16”
(259 mm)
7/8”*
(22 mm)
* The hole size can be increased to 1 1/8” by removing the conduit bracket
inside the range electrical access box.
B
Gas
inlet
A
C
7/8” (22 mm) Dia. electrical
connection hole in bottom*
D
Range electrical access,
cover removed
BACK OF RANGE
Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated
Document # PG05-003
Revised 02/03/11
Page 2/3