Dacor ER30DSR Planning Guides - Page 2
Planning, Guide - range
View all Dacor ER30DSR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
Document # PG05-003 ER30D, ER30DSR Epicure® Ranges Revised 02/03/11 Page 2/3 PLANNING GUIDE Product tolerances: ±1/16" (±1.6 mm) unless otherwise stated GAS - ELECTRICAL ACCESS DIMENSIONS A B C D E 4 7/8" (124 mm) 21 3/4" (552 mm) 8 5/8" (219 mm) 10 3/16" (259 mm) 7/8"* (22 mm) B D Gas inlet Range electrical access, cover removed A C 7/8" (22 mm) Dia. electrical connection hole in bottom* back of range Cabinet tolerances: +1/16", (+1.6 mm) -0 F 13" (330 mm) Max.4 * The hole size can be increased to 1 1/8" by removing the conduit bracket inside the range electrical access box. Gas and Electrical Service ■■ The shaded area (diagram bottom left) denotes the location of the gas inlet and the electrical junction box/receptacle. This is the recommended location. For replacement purposes, the location of the existing utilities may be utilized provided they do not interfere with the sides or rear of the range. Check local building codes for permissible gas valve and electrical locations. ■■ An external manual shut-off valve must be installed between the gas inlet and the range, for the purpose of turning on or shutting off gas to the appliance. The installation must allow for the following: ■■ Access to the gas shut-off valve when the unit is installed. ■■ Access to the remote circuit breaker panel/fuse box, when the range is in place. ■■ The gas supply piping and shut-off valve, and the electrical junction box/receptacle must be located so they do not interfere with the range when it is installed. ■■ The junction box and gas shut off valve must be located so that the range can be pulled out for service while the appliance remains connected. GAS SUPPLY PRESSURE REQUIREMENTS* Gas Type Manifold Pressure Minimum Gas Supply Pressure Natural Gas 5" Water Column 6" Water Column Petroleum (LP) 10" Water Column 11" Water Column * Maximum input gas supply pressure for all models is 1/2 p.s.i. 18" (457 mm) Min.1, 4 Non-combustible surface along back wall recommended 30" (762 mm) Min.1 G 10" (254 mm) Min. to combustible side walls above the range (both sides) Note 2 36 1/2" (927 mm) Max. Suggested location of utilities 3 1 Vertical to combustible surface from range grate level; if installing an overhead vent hood, also check the hood specifications for minimum required clearances. 2 Cabinet/countertop depth is at discretion of customer but cabinet face MUST NOT protrude further than rear of front panel, see product dimensions. 3 Consult local code for exact location requirements. 4 Not applicable for cabinets more than a horizontal distance of 10" (254 mm) from the edge of the range. CUT-OUT DIMENSIONS F G 36" (914 mm)* 30" (762 mm)** 30 1/16" (916 mm)* * Recommended ** Minimum Cabinet cutout dimensions MODELS ER30D AND ER3OD-C NOTE: See following page for countertop/cabinet cutout dimensions for self-rimming installations Specifications subject to change without notice. www.Dacor.com Phone: (800) 7935-0.8093