Dacor ERV48 Installation Instructions - Page 6
Installation Specifications
View all Dacor ERV48 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
Installation Specifications warning • Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. • The electric outlet for the raised vent should be installed only by a licensed electrician. Electrical Specifications The raised vent is supplied with a 28" (711 mm) power cord terminated by a three-prong plug. Plug it directly into a dedicated, grounded, three prong, electrical outlet. Do not use an extension cord. The correct voltage, frequency and amperage must be supplied to the electrical outlet from a grounded, single phase circuit that is protected by a properly sized circuit breaker or time-delay fuse. Electrical Supply Requirements • A three-prong electrical outlet connected to a 120 Vac, 60 Hz, 15 Amp. grounded, dedicated circuit is required. • The customer must supply wiring/conduit with minimum current carrying capacity of 8 Amps. to supply power to the remote or in-line blower from the raised vent. See General System Layout and Planning the Duct Work for further details. • The above specifications are for reference only. If the power supply requirements shown above do not agree with those listed on the product data label, use the required voltage, frequency and amperage ratings on the label. • It is the owner's responsibility to ensure that electrical outlet is installed by a licensed electrician. The electrical installation must comply with the latest revision of the National Electric Code ANSI/NFPA 70* (latest revision) and local codes and ordinances. *A copy of this standard may be obtained from: National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101 • Locate the electrical outlet in an accessible location, so that the power plug can be disconnected for service without removing the raised vent or the range from the cabinet. Planning the Installation General System Layout The vent system consists of the raised vent itself and a single Dacor approved remote or in-line blower (see page 6). warning • Failure to install an approved remote or in-line blower or proper duct work will result in a back draft and/or the insufficient venting of smoke and fumes. • To reduce the risk of personal injury caused by reaching over a hot appliance, cabinet storage space located directly above the range should be avoided. • Do not store combustible materials or items adversely affected by heat in cabinet areas above the appliance. • Follow the instructions and diagrams for minimum safe clearances and installation location in these instructions, the appliance installation instructions and the remote or in-line blower installation instructions. Failure to do so may result in a fire or safety hazard. • Wire the remote or in-line blower to turn on when the raised vent is turned on by running wiring/conduit parallel to the duct work and connecting it to the raised vent on one end and the blower on the other. There are 7/8" access holes in the bottom and side of the raised vent for connecting the conduit/strain relief. Front of unit Blower wiring access hole in side Blower wiring access hole in bottom Electrical Access Hole Locations for Blower Connection 4