Document # PG03-002 ETT304-1 and ETT365-2 30 Inch and 36 Inch Wide, Renaissance® Electric Cooktops All tolerances: +1/16", -0, (+1.6 mm, -0) unless otherwise stated Revised 10/01/11 Page 2/3 PLANNING GUIDE Allow a minimum of 6 inches (15.2 cm) clearance between the top of the countertop and any combustible surface below, including the upper edge of a drawer below the cooktop. Proper under-cabinet clearance is also required for the cooktop hold down brackets. When installing model ETT365-2 and the bottom of the chassis is to be enclosed wall to wall, you must install Dacor ventilation duct kit ATD323. 6" (15.2 cm) min. clearance to combustible A surfaces Model (A) Minimum Under Counter Clearance (Width) ETT304-1 ETT365-2 30 1/2" (77.5 cm) 36 1/2" (92.7 cm) 3/4" under counter clearance 7 3/4" X 4 3/8" ventilation cut-outs in enclosure floor Cooktop cutout in top of cabinet 1 1/2" 1 1/2" 3/4" top vieW VENTILATION cutoUT Rear wall Model ETT304-1 ETT365-2 (B) Minimum Under Counter Clearance (Width) 28 3/4" (73.0 cm) 34 3/4" (88.3 cm) 6" (15.2 cm) min. from mounting surface to combustibles below cooktop chassis B 2 1/4" min. (5.7 cm) 19 3/4" min. (50.2 cm) 1" min. (2.5 cm) 6" (15.2 cm) min. to combustible, side wall, both sides Countertop cutout (without raised vent) Specifications subject to change without notice. www.dacor.com Phone: (800) 7933-0.5093

  • 1
  • 2
  • 3

PLANNING
GUIDE
Specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
30 Inch and 36 Inch Wide,
Renaissance
®
Electric Cooktops
ETT304-1 and ETT365-2
All tolerances: +1/16”, -0,
(+1.6 mm, -0) unless otherwise stated
Document # PG03-002
Revised 10/01/11
Page 2/3
When installing model ETT365-2 and the bottom of the chassis is to be enclosed
wall to wall, you must install Dacor ventilation duct kit ATD323.
Allow a minimum of 6 inches (15.2 cm) clearance between
the top of the countertop and any combustible surface
below, including the upper edge of a drawer below the
cooktop. Proper under-cabinet clearance is also required
for the cooktop hold down brackets.
6” (15.2 cm)
min. clearance
to combustible
surfaces
A
6" (15.2 cm) min.
from mounting surface to
combustibles below
cooktop chassis
B
min. to combustible,
side wall, both sides
Rear
wall
1" min.
19 3/4" min.
(50.2 cm)
6" (15.2 cm)
(2.5 cm)
2 1/4" min.
(5.7 cm)
UNDER COUNTER CLEARANCE
Model
(A) Minimum Under Counter
Clearance (Width)
ETT304-1
30 1/2” (77.5 cm)
ETT365-2
36 1/2” (92.7 cm)
Model
(B) Minimum Under Counter
Clearance (Width)
ETT304-1
28 3/4” (73.0 cm)
ETT365-2
34 3/4” (88.3 cm)
COUNTERTOP CUTOUT (WITHOUT RAISED VENT)
3
/
4
7
3
/
4
” X 4
3
/
8
” ventilation cut-outs in enclosure floor
1
1
/
2
1
1
/
2
3
/
4
TOP VIEW VENTILATION CUTOUT
Cooktop cutout in
top of cabinet