Dacor METB365-1 Installation Instructions - Page 5

Installation Specifications - 36 in electric cooktop

Page 5 highlights

Installation Specifications Product Dimensions All tolerances: ±1/16 (±1.6 mm), unless otherwise stated. 30 1/4" * (768 mm) 4" (102 mm) Chassis height 19 3/8" 21 1/4" * (495 mm) (540 mm) 28 3/8" (721 mm) 36 1/4" * (921 mm) 4" (102 mm) Chassis height Models ETT304-1, MET304 19 3/8" 21 1/4" * (495 mm) (540 mm) 34 3/8" (873 mm) * For units with stainless steel trim, other units may be up to 1/8" less Models ETT365-2, METB365-1 Electrical Specifications important This appliance is provided with electrical connection leads in a flexible metal conduit. These leads may be a smaller gage than the standard household wiring of the dedicated supply circuit, but they are suitable for connection to these circuits under the jurisdiction of the National Electric Code, and/or the local inspection authority. • It is the owner's responsibility to ensure that a licensed electrician performs the installation of the electrical supply for this appliance. The electrical installation, including minimum supply wire size, must comply with the National Electric Code ANSI/NFPA 70 (latest revision) and local codes and ordinances. A copy of the standard may be obtained from: National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101 • The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, grounded, circuit that is protected by a properly sized circuit breaker or time-delay fuse. If a time-delay fuse is utilized, fuse both sides of the line (L1 and L2). • The junction box and the remote circuit breaker panel or fuse box, must be accessible when the cooktop is in place. Model ETT304-1 ETT365-2 MET304 METB365-1 Dedicated Circuit Required 240 Vac, 60 Hz. 3 wire* 40 Amp. 240 Vac, 60 Hz. 3 wire* 40 Amp. 240 Vac, 60 Hz. 3 wire* 40 Amp. 240 Vac, 60 Hz. 3 wire* 50 Amp. Total Connected Load** 6.9 kW (29 Amp.) 9.1 kW (38 Amp.) 6.9 kW (29 Amp.) 9.6 kW (40 Amp.) * Two 120 Vac hot (L1 and L2) and one ground (all copper). ** For reference only. See the product data label (on the bottom of the unit) for exact specifications. The minimum wire size required by the manufacturer is 8 AWG. Local codes may require that minimum wire gauge used exceed this requirement for the power requirements listed on the product data label. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

3
Installation Specifications
Product Dimensions
36 1/4" *
(921 mm)
34 3/8"
(873 mm)
19 3/8"
(495 mm)
21 1/4" *
(540 mm)
4" (102 mm)
Chassis height
30 1/4" *
(768 mm)
28 3/8"
(721 mm)
19 3/8"
(495 mm)
21 1/4" *
(540 mm)
4" (102 mm)
Chassis height
Electrical Specifications
IMPORTANT
This appliance is provided with electrical connection
leads in a flexible metal conduit. These leads may be a
smaller gage than the standard household wiring of the
dedicated supply circuit, but they are suitable for connec-
tion to these circuits under the jurisdiction of the National
Electric Code, and/or the local inspection authority.
It is the owner’s responsibility to ensure that a licensed
electrician performs the installation of the electrical sup-
ply for this appliance. The electrical installation, includ-
ing minimum supply wire size, must comply with the
National Electric Code ANSI/NFPA 70 (latest revision)
and local codes and ordinances. A copy of the standard
may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
The correct voltage, frequency and amperage must be
supplied to the appliance from a dedicated, grounded,
circuit that is protected by a properly sized circuit
breaker or time-delay fuse. If a time-delay fuse is uti-
lized, fuse both sides of the line (L1 and L2).
The junction box and the remote circuit breaker panel
or fuse box, must be accessible when the cooktop is in
place.
Model
Dedicated
Circuit Required
Total Connected
Load**
ETT304-1
240 Vac, 60 Hz.
3 wire* 40 Amp.
6.9 kW
(29 Amp.)
ETT365-2
240 Vac, 60 Hz.
3 wire* 40 Amp.
9.1 kW
(38 Amp.)
MET304
240 Vac, 60 Hz.
3 wire* 40 Amp.
6.9 kW
(29 Amp.)
METB365-1
240 Vac, 60 Hz.
3 wire* 50 Amp.
9.6 kW
(40 Amp.)
* Two 120 Vac hot (L1 and L2) and one ground (all copper).
** For reference only. See the product data label (on the
bottom of the unit) for exact specifications. The minimum
wire size required by the manufacturer is 8 AWG. Local
codes may require that minimum wire gauge used exceed
this requirement for the power requirements listed on the
product data label.
Models ETT304-1, MET304
Models ETT365-2, METB365-1
All tolerances: ±1/16 (±1.6 mm), unless otherwise stated.
* For units with stainless steel trim,
other units may be up to 1/8” less