Dacor METB365-1 Installation Instructions - Page 5
Installation Specifications - 36 in electric cooktop
View all Dacor METB365-1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
Installation Specifications Product Dimensions All tolerances: ±1/16 (±1.6 mm), unless otherwise stated. 30 1/4" * (768 mm) 4" (102 mm) Chassis height 19 3/8" 21 1/4" * (495 mm) (540 mm) 28 3/8" (721 mm) 36 1/4" * (921 mm) 4" (102 mm) Chassis height Models ETT304-1, MET304 19 3/8" 21 1/4" * (495 mm) (540 mm) 34 3/8" (873 mm) * For units with stainless steel trim, other units may be up to 1/8" less Models ETT365-2, METB365-1 Electrical Specifications important This appliance is provided with electrical connection leads in a flexible metal conduit. These leads may be a smaller gage than the standard household wiring of the dedicated supply circuit, but they are suitable for connection to these circuits under the jurisdiction of the National Electric Code, and/or the local inspection authority. • It is the owner's responsibility to ensure that a licensed electrician performs the installation of the electrical supply for this appliance. The electrical installation, including minimum supply wire size, must comply with the National Electric Code ANSI/NFPA 70 (latest revision) and local codes and ordinances. A copy of the standard may be obtained from: National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101 • The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, grounded, circuit that is protected by a properly sized circuit breaker or time-delay fuse. If a time-delay fuse is utilized, fuse both sides of the line (L1 and L2). • The junction box and the remote circuit breaker panel or fuse box, must be accessible when the cooktop is in place. Model ETT304-1 ETT365-2 MET304 METB365-1 Dedicated Circuit Required 240 Vac, 60 Hz. 3 wire* 40 Amp. 240 Vac, 60 Hz. 3 wire* 40 Amp. 240 Vac, 60 Hz. 3 wire* 40 Amp. 240 Vac, 60 Hz. 3 wire* 50 Amp. Total Connected Load** 6.9 kW (29 Amp.) 9.1 kW (38 Amp.) 6.9 kW (29 Amp.) 9.6 kW (40 Amp.) * Two 120 Vac hot (L1 and L2) and one ground (all copper). ** For reference only. See the product data label (on the bottom of the unit) for exact specifications. The minimum wire size required by the manufacturer is 8 AWG. Local codes may require that minimum wire gauge used exceed this requirement for the power requirements listed on the product data label. 3