Dacor MH3618 Installation Instructions - Page 21

Final Electrical Installation

Page 21 highlights

Installation Instructions Final Electrical Installation warning • To avoid electric shock or fire hazard, prior to connecting the electrical wiring to the hood, make sure that power to the hood power supply line is turned off at the fuse box or circuit breaker panel. • Improper connection of the hood electrical wiring may create an electric shock or fire hazard and may result in damage to the hood's electrical system. See page 6 for specifications. • Do not ground the hood to the neutral (white) power supply wire. Connect the hood ground wire to a separate, properly grounded wire installed by a licensed electrician. • Make sure all wire used is capable of handling the total connected load. See page 3. 1. Turn off power to the hood electrical circuit at the circuit breaker or fuse box. 2. Feed the wiring through the wiring access holes in the hood. Connect the wiring to the terminal block inside the hood as shown. 3. Connect the hood wiring to an electrical junction box on a dedicated circuit. See page 6 for specifications. Connect it according to the wiring diagram below or on the following page. To house circuit breaker panel or fuse box Junction box Wire nut, 3 places GREEN GREEN WHITE WHITE BLACK BLACK Neutral (white) Ground (green) Hot (black) To junction box Not used N1 Gnd L1 Hood power terminals UL/CSA approved NEMA strain relief To range hood 3 Wire Connection to Junction Box 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

19
Turn off power to the hood electrical circuit at the circuit
1.
breaker or fuse box.
Feed the wiring through the wiring access holes in the
2.
hood. Connect the wiring to the terminal block inside
the hood as shown.
Connect the hood wiring to an electrical junction box
3.
on a dedicated circuit. See page 6 for specifications.
Connect it according to the wiring diagram below or on
the following page.
L1
N1
Gnd
Not used
Installation Instructions
To junction
box
Hood power
terminals
Ground (green)
Neutral (white)
Hot (black)
GREEN
GREEN
WHITE
WHITE
BLACK
BLACK
3 Wire Connection to Junction Box
UL/CSA approved
NEMA strain relief
To house circuit breaker
panel or fuse box
To range hood
Junction box
Wire nut,
3 places
Final Electrical Installation
WARNING
To avoid electric shock or fire hazard, prior to connecting the electrical wiring to the hood, make sure that power to
the hood power supply line is turned off at the fuse box or circuit breaker panel.
Improper connection of the hood electrical wiring may create an electric shock or fire hazard and may result in dam-
age to the hood’s electrical system. See page 6 for specifications.
Do not ground the hood to the neutral (white) power supply wire. Connect the hood ground wire to a separate, prop-
erly grounded wire installed by a licensed electrician.
Make sure all wire used is capable of handling the total connected load. See page 3.