Dacor MORS130 Installation Instructions - Page 6

Product Specifications - mors130s

Page 6 highlights

Product Specifications Power Supply Requirements • It is the owner's responsibility to ensure that a licensed electrician performs the installation of the electrical supply for this appliance. The electrical installation, including minimum supply wire size, must comply with the National Electric Code ANSI/NFPA 70 (latest revision) and local codes and ordinances. A copy of this standard may be obtained from: National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101 • The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, grounded, single phase circuit that is protected by a properly sized circuit breaker or time-delay fuse. If a time-delay fuse is utilized, fuse both sides of the line (L1 and L2). • The required voltage, frequency and amperage ratings are listed on the appliance data plate (see page 3) and in the table for reference. • Preheat times and cavity temperature recovery times will be increased slightly if operating the unit with less than a 240 Vac circuit. • This appliance is provided with electrical wiring in a flexible metal conduit. Model Number EORS127 MORS127 EORS130 MORS130 EORS136 EORS227 MORS227 EORS230 MORS230 EORD227 MORD227 EORD230 MORD230 Dedicated Circuit Total Connected Requirements Load 240 Vac 60 Hz, 4 wire*, 30 Amp. 5.0 kW (21 Amp.) 5.3 kW (22 Amp.) 240 Vac 60 Hz, 4 wire*, 40 Amp. 7.8 kW (33 Amp.) 240 Vac 60 Hz, 4 wire*, 50 Amp. 10.0 kW (42 Amp.) * Two 120 Vac hot (L1 and L2), one neutral, one ground. The above specifications are for reference only. See the appliance data plate (page 3) for exact specifications. Product Dimensions All tolerances: ±1/16 (±1.6 mm), unless otherwise stated. Model Number EORS127/ MORS127 EORS130/ MORS130 EORS136 EORX227/ MORX227 Overall Width (A) 26 7/8" (68.3 cm) 29 7/8" (75.9 cm) 35 7/8" (91.1 cm) 26 7/8" (68.3 cm) EORX230/ 29 7/8" MORX230 (75.9 cm) Chassis Width (B)* 25 3/8" (64.5 cm) 28 3/8" (72.1 cm) 34 3/8" (87.3 cm) 25 3/8" (64.5 cm) 28 3/8" (72.1 cm) Overall Chassis Control Panel Height (C) Height (D)** Overlay (E) 28 7/16" (72.2 cm) 27 1/2" (69.9 cm) 15/16" (23.8 cm) 28 1/8" (71.4 cm) 27 1/4" (69.2 cm) 7/8" (2.2 cm) 49 15/16" 49 1/16" (126.8 cm) (124.6 cm) 7/8" (2.2 cm) X = Number of convection ovens, see page 3 * Width at light covers on sides ** To top of chassis notch behind control panel All Models Utility Cutout Width (F) 5" (12.7 cm) Utility Cutout Height (G) 5 ¼" (13.3 cm) Utility Cutout Depth (H) 6" (15.2 cm) Control Panel Depth (J) 1" (2.54 cm) Notch Depth (K) 1 1/8" (2.9 cm) Chassis Notch Depth (L) Height (M) 24" (61.0 cm) 1" (2.5 cm) 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

4
Power Supply Requirements
It is the owner’s responsibility to ensure that a licensed
electrician performs the installation of the electrical sup-
ply for this appliance. The electrical installation, includ-
ing minimum supply wire size, must comply with the
National Electric Code ANSI/NFPA 70 (latest revision)
and local codes and ordinances.
A copy of this standard may be obtained from:
The correct voltage, frequency and amperage must be
supplied to the appliance from a dedicated, grounded,
single phase circuit that is protected by a properly sized
circuit breaker or time-delay fuse. If a time-delay fuse is
utilized, fuse both sides of the line (L1 and L2).
The required voltage, frequency and amperage ratings
are listed on the appliance data plate (see page 3) and
in the table for reference.
Preheat times and cavity temperature recovery times
will be increased slightly if operating the unit with less
than a 240 Vac circuit.
This appliance is provided with electrical wiring in a
flexible metal conduit.
Product Specifications
Model
Number
Dedicated Circuit
Requirements
Total Connected
Load
EORS127
240 Vac 60 Hz,
4 wire*, 30 Amp.
5.0 kW (21 Amp.)
MORS127
EORS130
MORS130
EORS136
5.3 kW (22 Amp.)
EORS227
240 Vac 60 Hz,
4 wire*, 40 Amp.
7.8 kW (33 Amp.)
MORS227
EORS230
MORS230
EORD227
240 Vac 60 Hz,
4 wire*, 50 Amp.
10.0 kW (42 Amp.)
MORD227
EORD230
MORD230
* Two 120 Vac hot (L1 and L2), one neutral, one ground.
The above specifications are for reference only. See the
appliance data plate (page 3) for exact specifications.
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
Model
Number
Overall
Width (A)
Chassis
Width (B)*
Overall
Height (C)
Chassis
Height (D)**
Control Panel
Overlay (E)
EORS127/
MORS127
26 7/8”
(68.3 cm)
25 3/8”
(64.5 cm)
28 7/16”
(72.2 cm)
27 1/2”
(69.9 cm)
15/16”
(23.8 cm)
EORS130/
MORS130
29 7/8”
(75.9 cm)
28 3/8”
(72.1 cm)
EORS136
35 7/8”
(91.1 cm)
34 3/8”
(87.3 cm)
28 1/8”
(71.4 cm)
27 1/4”
(69.2 cm)
7/8”
(2.2 cm)
EORX227/
MORX227
26 7/8”
(68.3 cm)
25 3/8”
(64.5 cm)
49 15/16”
(126.8 cm)
49 1/16”
(124.6 cm)
7/8”
(2.2 cm)
EORX230/
MORX230
29 7/8”
(75.9 cm)
28 3/8”
(72.1 cm)
X = Number of convection ovens, see page 3
* Width at light covers on sides
** To top of chassis notch behind control panel
Product Dimensions
All tolerances: ±1/16 (±1.6 mm), unless otherwise stated.
Utility
Cutout
Width (F)
Utility
Cutout
Height (G)
Utility
Cutout
Depth (H)
Control
Panel
Depth (J)
Notch
Depth (K)
Chassis
Depth (L)
Notch
Height (M)
All Models
5”
(12.7 cm)
5 ¼”
(13.3 cm)
6”
(15.2 cm)
1”
(2.54 cm)
1 1/8”
(2.9 cm)
24”
(61.0 cm)
1”
(2.5 cm)