Dacor MORS130 Installation Instructions - Page 8

Installation Specifications - wall oven

Page 8 highlights

Installation Specifications Installation Planning • Dacor recommends installing the electrical junction box in the one of the locations shown. warning Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. important • Locate the junction box so that the oven may be easily disconnected in the event that it needs to be removed from the wall completely for service. • If the oven is not installed level it may deliver poor or inconsistent baking results. • Install the junction box in a location that allows the oven to be removed from the the cut out for service without being disconnected. • Plan the installation so that all minimum clearances are met or exceeded. Dimensions shown provide minimum clearances, unless otherwise noted. Be certain that proper clearance is provided for the oven door when it is in the open position according the Product Dimensions. • Cabinet cutout dimensions must be used as indicated. The specified minimum cabinet depth and width must be provided. The cabinet depth and width must completely enclose the recessed portion of the oven. • A qualified technician must complete the installation of • All contact surfaces between the appliance and the this built-in appliance. Proper installation is the respon- cabinet must be solid and level. sibility of the customer. • Provide a platform within the cabinet to support the • Carefully check the location where the oven is to be oven. It must be installed level and straight. The top installed. The oven should be placed for convenient edge of the platform must be flush with the cut out at access. Make certain that electrical power, meeting the front of the cabinet. There are no provisions to level the specifications on page 4, can be provided in the the oven after it has been installed. 3/4" (1.9 cm) thick selected location. plywood is recommended. Cabinet Dimensions Cabinet tolerances: +1/16 (1.6 mm), -0, unless otherwise stated. Model Number EORS127/ MORS127 EORS130/ MOCS130 EORS136 EORX227/ MORX227 Minimum Cabinet Width (N) 27" (68.6 cm) 30" (76.2 cm) 36" (91.4 cm) 27" (68.6 cm) Minimum Cut Out Width (P) 25 ½" (64.8 cm) 28 ½" (72.4 cm)) 34 ½" (87.6 cm) 25 ½" (64.8 cm) EORX230/ MORX230 30" (76.2 cm) 28 ½" (72.4 cm) X = Number of convection ovens, see page 3 Minimum Cut out Height (R) 27 5/8" (70.2 cm) 27 ½" (69.9 cm) 49 1/8" (124.8 cm) Minimum Interior Cabinet Depth: 24" (61.0 cm) 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

6
Installation Specifications
Installation Planning
WARNING
Observe all governing codes and ordinances during plan-
ning and installation. Contact your local building depart-
ment for further information.
IMPORTANT
Locate the junction box so that the oven may be easily
disconnected in the event that it needs to be removed
from the wall completely for service.
If the oven is not installed level it may deliver poor or
inconsistent baking results.
A qualified technician must complete the installation of
this built-in appliance. Proper installation is the respon-
sibility of the customer.
Carefully check the location where the oven is to be
installed. The oven should be placed for convenient
access. Make certain that electrical power, meeting
the specifications on page 4, can be provided in the
selected location.
Minimum Interior Cabinet Depth: 24” (61.0 cm)
Dacor recommends installing the electrical junction box
in the one of the locations shown.
Install the junction box in a location that allows the
oven to be removed from the the cut out for service
without being disconnected.
Plan the installation so that all minimum clearances
are met or exceeded. Dimensions shown provide mini-
mum clearances, unless otherwise noted. Be certain
that proper clearance is provided for the oven door
when it is in the open position according the
Product
Dimensions
.
Cabinet cutout dimensions must be used as indicated.
The specified minimum cabinet depth and width must
be provided. The cabinet depth and width must com-
pletely enclose the recessed portion of the oven.
All contact surfaces between the appliance and the
cabinet must be solid and level.
Provide a platform within the cabinet to support the
oven. It must be installed level and straight. The top
edge of the platform must be flush with the cut out at
the front of the cabinet. There are no provisions to level
the oven after it has been installed. 3/4” (1.9 cm) thick
plywood is recommended.
Model
Number
Minimum Cabinet
Width (N)
Minimum Cut Out
Width (P)
Minimum Cut out
Height (R)
EORS127/
MORS127
27”
(68.6 cm)
25 ½” (64.8 cm)
27 5/8” (70.2 cm)
EORS130/
MOCS130
30”
(76.2 cm)
28 ½” (72.4 cm))
EORS136
36” (91.4 cm)
34 ½” (87.6 cm)
27 ½” (69.9 cm)
EORX227/
MORX227
27” (68.6 cm)
25 ½” (64.8 cm)
49 1/8” (124.8 cm)
EORX230/
MORX230
30” (76.2 cm)
28 ½” (72.4 cm)
Cabinet Dimensions
X = Number of convection ovens, see page 3