Dell 341-1626 Owners Manual - Page 166
System inlet <, The system inlet temperature is greater than the upper critical
View all Dell 341-1626 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 166 highlights
Error Code TMP0118 TMP0119 TMP0120 TMP0121 VLT0204 Message Information Action Re-configure system to the minimum supported configuration. If issues persists, contact support. Message LCD Message Details Action The system inlet temperature is less than the lower warning threshold. System inlet temperature is outside of range. Ambient air temperature is too cool. Check the system operating environment. Message LCD Message Details Action The system inlet temperature is less than the lower critical threshold. System inlet temperature is outside of range. Ambient air temperature is too cool. Check the system operating environment. Message LCD Message Details Action The system inlet temperature is greater than the upper warning threshold. System inlet temperature is outside of range. Ambient air temperature is too warm or one or more fans may have failed. Check the system operating environment and review event log for fan failures. Message LCD Message Details Action The system inlet temperature is greater than the upper critical threshold. System inlet temperature is outside of range. Check Fans. Ambient air temperature is too warm or one or more fans may have failed. Check the system operating environment and review event log for fan failures. Message LCD Message Details The system board voltage is outside of the allowable range. System board voltage is outside of range. System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in fail-safe mode. 166