Dell Brocade 6510 Fabric OS Troubleshooting and Diagnostics Guide v7.1.0 - Page 98
Power-on self test
View all Dell Brocade 6510 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 98 highlights
10 Power-on self test Most information can be captured using the supportSave command and downloaded by FTP off the switch, but when you are collecting information from specialized commands, such as supportShow, this information has to be captured using a Telnet client. To save a set of files that customer support technicians can use to further diagnose the switch condition, enter the supportSave command. The command prompts for an FTP server, packages the following files, and sends them to the specified server: • The output of the supportShow command. • The contents of any trace dump files on the switch. • System message (RAS) logs. See also "Automatic trace dump transfers" on page 115. Power-on self test By default, when you power on the system, the boot loader automatically performs power-on self tests and loads a Fabric OS kernel image. The POST tests provide a quick indication of hardware readiness when hardware is powered up. These tests do not require user input to function. They typically operate within several minutes, and support minimal validation because of the restriction on test duration. Their purpose is to give a basic health check before a new switch joins a fabric. These tests are divided into two groups: POST1 and POST2. POST1 validates the hardware interconnect of the device, and POST2 validates the ability of the device to pass data frames between the ports. The specific set of diagnostic and test commands run during POST depends on the switch model. You can use the diagDisablePost command to disable both POST1 and POST2, and you can reenable it using the diagEnablePost command. Refer to the Fabric OS Command Reference for additional information about these commands. The following example shows a typical boot sequence, including POST messages: The system is coming up, please wait... Read board ID of 0x80 from addr 0x23 Read extended model ID of 0x16 from addr 0x22 Matched board/model ID to platform index 4 PCI Bus scan at bus 0 ::: ::: Checking system RAM - press any key to stop test Checking memory address: 00100000 System RAM test using Default POST RAM Test succeeded. Press escape within 4 seconds to enter boot interface. Booting "Fabric Operating System" image. Linux/PPC load: BootROM command line: quiet Uncompressing Linux...done. Now booting the kernel Attempting to find a root file system on hda2... 82 Fabric OS Troubleshooting and Diagnostics Guide 53-1002751-01