Dell DR4100 DR Series System Release Notes for Version 3.2.0.2 - Page 26
The BridgeHead, Networker and Unix_Dump, Networker or
View all Dell DR4100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
ID 18275 18215 18151, 17997, 14534 Issue Description After upgrading your system, backup jobs failed and containers became inaccessible due to the DR Series system leaving the domain. If you created a CIFS user named root or service, you could not delete it. Addition of additional DMA markers and changes to marker code for the DMAs that need marker detection. The BridgeHead, Networker and Unix_Dump markers must be set explicitly on a container and are not part of the Auto marker option. 18070 18001 17999 The command -system - -- show --hardware | grep -i NIC does not list 1 Gb NICs if you have 10 Gb in the system. The - .bashrc is missing rda from the complete -F line. During a system upgrade, the software upgrade stopped because it exited the CLI shell. 17863 17796 17702 17672 17660 After upgrading your system, you are prompted to reboot. The GUI will indicate that the reboot takes up to 10 minutes, which is the best case scenario. It can actually take up to 30 minutes, during which time your user interface can appear frozen. When the total number of Domain Controllers is very large, issues can occur when you try to add the machine to the domain. The RDS plug-in download page does not list the hybrid installer for the Windows operating system. It only lists the individual installers for the 32- bit and 64-bit platforms. You are unable to change default NetVault RDA password from the GUI when you use the system for the first time and no clients are connected. You get a platform not supported error when you upgrade the SUSE 11 NVBU plug-in from 32-bit to 64-bit on the same system. Workaround/Solution Corrected in the 3.0.0.1 release. Corrected in the 3.0.0.1 release. Corrected in the 3.0.0.1 release. The Auto setting (default) will recognize markers for the 2.X supported DMACommVault| TSM| ARCserve| HP_DataProtector. Newer Markers must be explicitly set using the appropriate selection BridgeHead, Networker or Unix_Dump. Corrected in the 3.0.0.1 release. Corrected in the 3.0.0.1 release. A message has been added instructing you to not interrupt the upgrade process. Corrected in the 3.0.0.1 release. Corrected in the 3.0.0.1 release. Corrected in the 3.0.0.1 release. Corrected in the 3.0.0.1 release. Corrected in the 3.0.0.1 release. 26