Dell Force10 E300 Dell Force10 E300, E600i, and E1200i Systems Quick Start Gui - Page 30
E300 Specifications, E300 Chassis Physical Design, E300 Environmental Parameters
View all Dell Force10 E300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
E300 Specifications E300 Chassis Physical Design Parameter E1200i AC Specifications Height 14 inches (35.6 cm) Width 17.4 inches (44.2 cm) Depth (without cable management system) 24 inches (61 cm) Chassis weight with factory-installed 90 pounds (approx.) (41 kg) components (backplane and air filter) Weight fully loaded (backplane, air 170 pounds (approx.) (77 kg) filter, 1 fan tray, 2 SFMs, 2 RPMs, and 6 line cards) Thermal Output Maximum for fully loaded chassis 2500 W (8500 BTU/hour) Normal operating conditions (25 deg.C, 2000 W (6800 BTU/hour) -48V-line) Minimum for chassis with one 24-port 800 W (2700 BTU/hour) 1GE line card E300 Environmental Parameters Parameter Specifications Operating Temperature 40° to 105°F (5° to 40°C) Maximum altitude No performance degradation to 10,000 feet (3,048 meters) Relative humidity 5 to 85 percent, non-condensing Non-operating Temperature -40° to 158°F (-40° to 70°C) Maximum Altitude 15,000 feet (4,572 meters) Relative Humidity 5 to 95 percent, non-condensing 28 Installing the Hardware