Dell Force10 E300 Dell Force10 E300, E600i, and E1200i Systems Quick Start Gui - Page 32
E600i TeraScale Environmental Parameters, E600i TeraScale AC Power Supply Unit Requirements - e600i cable management
View all Dell Force10 E300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
Parameter Specifications Width 17.4 inches (44.2 cm) Depth (without cable management system) 21.5 inches (54.6 cm) Chassis weight with factory-installed 81 pounds (36.7 kg) components (backplane and air filter) Weight fully loaded (backplane, air 242 pounds (109.8 kg) filter, fan tray, SFMs, RPMs, and 7 line cards) Maximum Thermal Output NOTE: Thermal output is directly proportional to system configuration and number of line cards. Maximum for fully loaded chassis 120 VAC powered: 4705W (16,065 BTU/hour) 200/240 VAC powered: 4250W (14,500 BTU/hour) DC powered: 2800W (9600 BTU/hour) E600i TeraScale Environmental Parameters Parameter Specifications Operating Temperature 32° to 104°F (0° to 40°C) Maximum altitude No performance degradation to 10,000 feet (3,048 meters) Relative humidity 5 to 85 percent, non-condensing Non-operating Temperature -40° to 158°F (-40° to 70°C) Maximum Altitude 15,000 feet (4,572 meters) Relative Humidity 5 to 95 percent, non-condensing E600i TeraScale AC Power Supply Unit Requirements Parameter Specifications Nominal input voltage 120 - 240 VAC 50/60 Hz 30 Installing the Hardware