State, State Name, Blinking Amber, Pattern, Problem Description, Suggested, Resolution
View all Dell OptiPlex 5055 Ryzen APU Tower manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 82 highlights
Table 35. Diagnostic power LED codes (continued) State State Name Blinking Amber Pattern Problem Description S6 STO 3 blinks > short pause > No Memory detected 3 blinks > long pause > repeats Suggested Resolution If customer can assist to troubleshoot, narrow down the issue by removing one by one memory to determine which one failed and swapping to a known good memory if available to confirm. If identified the memory failed, replace the memory. If none of the memory failed, replace the motherboard. S7 USB 3 blinks > short pause > Storage Subsystem Possible storage failure 4 blinks > long pause > repeats device configuration in progress or storage subsystem failure. If customer can assist to troubleshoot, narrow down the issue by removing one by one storages on motherboard to determine which one failed. If identified the storage failed, replace the storage. If identified the storage failed, replace the storage. S8 MEM 3 blinks > short pause > Memory configuration Memory subsystem or incompatible error 5 blinks > long pause > repeats configuration activity is in progress. No memory modules were detected. If customer can assist to troubleshoot, narrow down the issue by removing one by one the memory on motherboard to determine which one failed. Also, combining the configuration to validate appropriate combination. If identified the component failed, replace the component. If none of the component 82 Troubleshooting