Dell PowerConnect 3348 Release Notes - Page 7
Access Control List ACL, Clock Settings, Stacking
View all Dell PowerConnect 3348 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
PowerConnect 3324/3348 Release Notes Title Description PowerConnect 3324/3348". Access Control List (ACL) Title Deleting Access Control Lists Clock Settings Title Setting Time and date. Stacking Title Stacking Synchronization and Bridge initialization Description An Access Control List (ACL) can be deleted even if it is bound to an interface. Deletion of the ACL results in automatic unbinding of the ACL from all interfaces to which it had been bound. If/when the interface is again created; the ACL will automatically be bound to it. For example: create VLAN n, bind ACL x to it. If VLAN n is deleted, the ACL remains "bound" fictively. When VLAN n is recreated, ACL x is "automatically" bound to it. Work-around: Delete the ACL and re-create it. Description PowerConnect 3324/3348 does not have a real time Clock. So date and time must be set if device is rebooted. Description Stack ring must be fully synchronized before master initializes bridge. If stack ring is open (cables disconnected) for more than two minutes a reboot will occur. Bridge is not enabled after reboot if stack ring is still disconnected. System Firmware Version 1.1.0.42 Page 4