Dell PowerConnect Brocade M5424 Brocade 7.1.0 Fabric OS Message Reference Guid
Dell PowerConnect Brocade M5424 Manual
View all Dell PowerConnect Brocade M5424 manuals
Add to My Manuals
Save this manual to your list of manuals |
Dell PowerConnect Brocade M5424 manual content summary:
- Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 1
53-1002749-01 ® 14 December 2012 Fabric OS Message Reference Supporting Fabric OS v7.1.0 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 2
concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes visit http://www.brocade.com/support/oscd. Brocade Communications Systems, Incorporated Corporate and Latin American Headquarters Brocade Communications Systems, - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 3
1000046-02 Minor updates to a few messages. Reference Manual June 2006 Fabric OS Message Reference 53-1000242-01 Updated -Deleted USWD chapter. -Updated Introductory chapters. -Updated throughout: rebranding, supported hardware, CLI changes. June 2007 Fabric OS Message Reference 53-1000600-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 4
Title Fabric OS Message Reference Fabric OS Message Reference Fabric OS Message Reference Fabric OS Message Reference Publication Summary of changes Date number 53-1001157-01 Updated for Fabric OS v6.2.0: -Revised and added new messages to FSS, KSWD, CTAP, CNM, CVLM, EM, FABR, FCIP, FW, HIL, - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 5
Title Fabric OS Message Reference Fabric OS Message Reference Fabric OS Message Reference Publication Summary of changes Date number 53-1002149-01 Updated for Fabric OS v7.0.0: -Added new chapters: C3, CAL, MCAST_SS, RTE, and VS. -Added new messages: AG, AN, ANV, BL, C2, CDR, CCFG, ECC, EM, - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 6
- Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 7
How this document is organized xiii Supported hardware and software xiii What's new xix Notice to the reader xix Additional information xix Brocade resources xix Other industry resources xix Getting technical help content on switch 14 Fabric OS Message Reference vii 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 8
message 23 Reading an Audit message 24 Responding to a system message 26 Looking up a system message 26 Gathering information about the problem 26 Support 27 System module descriptions 28 Log Messages Audit Messages FFDC Messages Fabric OS System Messages AG Messages 121 AN Messages 136 ANV - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 9
Fabric OS Message Reference 53-1002749-01 AUTH Messages 144 BKSW Messages 162 BL Messages 163 BLS Messages 180 BM Messages 182 C2 Messages 187 C3 Messages 194 CAL Messages 202 CCFG Messages 203 CDR Messages 207 CHS Messages 214 CNM Messages 216 CONF Messages 239 CTAP Messages 244 CVLC - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 10
FW Messages 438 HAM Messages 541 HAMK Messages 546 HIL Messages 548 HLO Messages 565 HMON Messages 567 HSL Messages 568 HTTP Messages 571 IBD Messages 572 IPAD Messages 573 IPS Messages 575 ISNS Messages 578 KAC Messages 582 KSWD Messages 587 KTRC Messages 588 L2SS Messages 590 L3SS - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 11
PORT Messages 657 PS Messages 660 PSWP Messages 664 RAS Messages 667 RCS Messages 672 RKD Messages 677 RMON Messages 679 RPCD Messages 680 RTE Messages 683 RTWR Messages 684 SCN Messages 686 SEC Messages 688 SFLO Messages 771 SNMP Messages 774 SPC Messages 777 SPM Messages 790 SS - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 12
xii Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 13
parts of procedures documented here apply to some switches but not to others, this guide identifies exactly which switches are supported and which are not. Although many different software and hardware configurations are tested and supported by Brocade Communications Systems, Inc. for Fabric OS v7 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 14
are supported by this release of Fabric OS: • Brocade 300 • Brocade 5100 • Brocade 5300 • Brocade 5410 • Brocade 5424 • Brocade 5430 • Brocade 5450 • Brocade 5460 • Brocade 5470 • Brocade 5480 • Brocade 6505 • Brocade 6510 • Brocade 6520 • Brocade 7800 • Brocade 8000 • Brocade Encryption Switch - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 15
What's new in this document The following changes have been made since this document was last released: • The lookup lists in Chapter 2 through Chapter 4 provide hyperlinks to messages by type (LOG, Audit, and FFDC). • Information that was added: - AG Messages - ANV Messages - BL Messages - C2 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 16
• Information that was changed: - AN Messages - AUTH Messages - BL Messages - C2 Messages - C3 Messages - CDR Messages - CAL Messages - CNM Messages - DOT1 Messages - FABR Messages - FCOE Messages - FCPD Messages - FCR Messages - FICU Messages - FSPF Messages - FSS Messages - HIL Messages - HSL - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 17
titles code text Identifies CLI output Identifies command syntax examples For readability, command names in the narrative portions of this guide are presented in mixed lettercase: for example, switchShow. In actual examples, command lettercase is all lowercase. Command syntax conventions Command - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 18
cautions, and warnings The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards be potentially hazardous to you or cause damage to hardware, firmware, software, or data. DANGER A Danger statement indicates conditions - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 19
and Fibre Channel, see the technical glossaries on MyBrocade. See "Brocade resources" on page xix for instructions on accessing MyBrocade. For definitions of SAN-specific terms, visit the Storage Networking Industry Association online dictionary at: http://www.snia.org/education/dictionary Notice - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 20
switch support supplier for hardware, firmware, and software support problem, including the switch or fabric behavior immediately following the problem, and specific questions • Description of any troubleshooting right side and directly above the cable management comb. • Brocade DCX-4S and DCX 8510-4- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 21
switch is inoperable, you can get the WWN from the same place as the serial number, except for the Brocade DCX. For the Brocade DCX, access the numbers on the WWN cards by removing the Brocade from you. Forward your feedback to: [email protected] Provide the title and version number of the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 22
xxii Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 23
Responding to a system message 26 •System module descriptions 28 Overview of system messages This guide supports Fabric OS v7.1.0 and documents system messages that can help you diagnose and fix problems with a switch or fabric. The messages are organized alphabetically by module name. A module is - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 24
is designed to support post-event audits and problem determination based on high-frequency events of certain types such as security violations, zoning configuration changes, firmware downloads, and certain types of fabric events. Audit messages flagged as AUDIT are not saved in the switch error logs - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 25
Fabric (Logical Switch)-related changes. You can audit the CLI commands executed on the switch. Used to audit the problem. FFDC is intended for use by Brocade technical support. FFDC is enabled by default. Execute to be used as general guidelines for troubleshooting. For all cases, you must look - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 26
software has detected serious problems that will cause power supply is replaced or fixed. Info RASLog service generates and to nonvolatile storage by default. • The system switch reboots. • Trace dump, FFDC, and core dump files can be uploaded to the FTP server using the supportSave command. • Brocade - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 27
or any other operating system that supports the standard syslogd functionality. Configuring for syslogd involves configuring the host, enabling syslogd on the Brocade model, and, optionally, setting the facility level. For the Brocade DCX family of switches, each control processor (CP) has a unique - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 28
for the system console, perform the following steps. 1. Log in to the switch as admin. 2. Execute the errFilterSet [-d console -v severity] command to set (1) • Error (2) • Warning (3) • Informational (4) • Debug (5) By default, the severity level is set to None, implying all traps are filtered and - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 29
, the SNMP agent cannot determine if the trap was received. Brocade switches send traps out on UDP port 162. To receive traps, the Trap recipient Severity level: 5 Community 3: private (rw) Trap recipient: tools.lab.brocade.com Trap port: 162 Trap recipient Severity level: 5 Community 4: public (ro) - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 30
to receive the trap, perform the following steps. 1. Log in to the switch as admin. 2. Execute the snmpConfig --set snmpv3 command to configure the SNMP FOS user database will have physical AD and admin role as the default): User (rw): [snmpadmin1] Auth Protocol [MD5(1)/SHA(2)/noAuth(3)]: (1..3) - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 31
all event notifications. Otherwise, use the SNMP traps. Brocade devices support SNMPv3 informs. Configuring the SNMPv3 inform recipient To configure enable the SNMP informs, enter true or t. Informs are disabled by default. switch:admin> snmpconfig --set snmpv3 SNMP Informs Enabled (true, t, false, - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 32
and the management station. 3. Execute the snmpConfig --show snmpv3 command to verify the SNMP agent configuration. switch:admin> snmpconfig --show snmpv3 SNMP Informs = 1 (ON) SNMPv3 USM configuration: User 1 (rw): snmpadmin1 Auth Protocol: noAuth 10 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 33
entries. Port logs capture switch-to-device, device-to-switch, switch-to-switch, some device A-to-device . Port logs are typically used to troubleshoot device connections. Changing the severity level of , is sent to the configured trap recipients. By default, the severity level is set at 0 (None), implying - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 34
command to configure MIBs interactively. All the supported MIBs and associated traps are displayed. You can change the DesiredSeverity for swEventTrap to 1 (Critical), 2 (Error), 3 (Warning), or 4 (Informational). The default value is 0. switch:admin> snmpconfig --set mibcapability FE-MIB: YES - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 35
portLogEventShow portLoginShow portLogPdisc portLogReset Configures the audit message log. Displays or clears the audit log. Clears all error log messages for all switch instances on this control processor (CP). Sets the error log start and end delimiter for messages pushed to the console. Displays - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 36
change the default severity level for a specified message, and to display configured RASLog message settings. Displays message documentation on switch. Sets the . This output is used by your switch service provider to diagnose and correct problems with the switch. The output from this command is very - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 37
cannot be installed on a fabric with FCR service enabled. In case Top Talker must be installed configure the event classes you want to audit. switch:admin> auditcfg --class 1,2,3,4,5,6,7,8 Audit filter is want to set the Audit severity level. By default, all messages are logged. When the severity - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 38
1 Configuring system messages and attributes 5. Execute the auditCfg --show command to verify the configuration. switch:admin> auditcfg --show Audit filter is enabled. 1-ZONE 2-SECURITY 3-CONFIGURATION 4-FIRMWARE 5-FABRIC 6-FW 7-LS 8-CLI Severity level: ERROR You must configure the syslog daemon to - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 39
message, perform the following steps. 1. Log in to the switch as admin. 2. Use the rasadmin --set -log message_ID -severity [DEFAULT | INFO | WARNING | ERROR | CRITICAL] to change the . These procedures are valid for all the supported platforms. Fabric OS Message Reference 17 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 40
is enabled. 2000/12/17-05:55:04, [FCR-1068], 4, FID 128, INFO, switch, The FC Routing service is disabled. 2000/12/17-05:55:11, [EM-1034], 5, CHASSIS, ERROR, switch, PS 2 set to faulty, rc=2000e. [...] Displaying RASLog messages one message at a time To display the system message log one message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 41
2011/01/14-06:07:33 (UTC), [SULB-1003], INFO, FIRMWARE, admin/admin/192.0.2.2/telnet/CLI ad_0/switch, , Firmwarecommit has started. 4 AUDIT, 2011/12/11-10:08:58 (UTC), [SULB-1004], INFO, FIRMWARE, admin/admin/192.0.2.2/telnet/CLI ad_0/switch, , Firmwarecommit has completed. 5 AUDIT, 2012/05/23-03:45 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 42
a module: • Execute the rasadmin --show -all command to the status of all RASLog messages in the system log. switch:admin> rasadmin --show -all Message Status Default Severity FCIP-1000 ENABLED CRITICAL FCIP-1001 ENABLED INFO FCIP-1002 ENABLED INFO [...] Current Severity CRITICAL ERROR INFO - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 43
To display the RASLog messages based on the severity level, perform the following steps. 1. Log in to the switch as admin. 2. Execute the errdump --severity [DEFAULT | INFO | WARNING | ERROR | CRITICAL] command. For more information on message severity levels, refer to "Message severity levels" on - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 44
, CP/1 IPv6 manual fe80::224:38ff:fe1b:4400 DHCP Off. 2012/06/19-03:29:15, [IPAD-1000], 48, SLOT 4 | CHASSIS, INFO, switch, CP/0 Ether/0 IPv6 autoconf fd00:60:69bc:816:205:1eff:fe84:3f49/64 tentative DHCP Off. [...] NOTE The slot option is not supported on the non-bladed systems. Viewing RASLog - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 45
IP Addr:192.0.2.2. NOTE Any reference to slot 0 in a system message is a reference to the blade within the switch platform, for example, Brocade DCX contains FC8-48 blade, FC8-32 blade, FC8-16 blade, and so on. The fields in the error message are described in Table 4. TABLE 4 System message field - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 46
range from 0 to 128. FID 128 means the message was generated by the default switch instance. • CHASSIS - The message that was generated by the chassis instance. related information of interest for post-event auditing and troubleshooting the problem. The following example shows the format of the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 47
in the log. Identifies the message as an Audit message. The system time (UTC) when the message was generated on the switch. The RASLog subsystem will support an internationalized time stamp format based on the "LOCAL" setting. The message module and number. These values uniquely identify each - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 48
. Looking up a system message Messages in this manual are arranged alphabetically by Module ID, and then numerically problem Questions to ask yourself when troubleshooting a system message are as follows: • What is the current Fabric OS level? • What is the switch hardware version? • Is the switch - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 49
command on each logical switch. • Execute the supportFtp command (as needed) to set up automatic FTP transfers, and then execute the supportSave command. Support Fabric OS creates a number of files that can help support personnel troubleshoot and diagnose a problem. This section describes those - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 50
documented in this guide; the system Brocade 7800 and FX8-24 blade. Blade management error messages are a result of autoleveling firmware upgrades performed by the control processor (CP). C2 error messages indicate problems switch parameters in an object model. CCFG error messages indicate problems - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 51
The environmental monitor (EM) manages and monitors the various field-replaceable units (FRUs), including the port cards, control processor (CP) mechanism utilized by switches to exchange vendor and support information. ESW error messages indicate problems with the Ethernet switch module of Fabric - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 52
service. A component is a module in the Fabric OS, implementing a related set of functionality. A service status messages. KAC error messages indicate problems associated with Fabric OS and the (emd) • Event Manager daemon (evmd) • Exchange Switch Support daemon (essd) • FA-API rpc daemon (rpcd) - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 53
daemon (ssmd) • Time Service daemon (tsd) • TRACE daemon (traced) • Traffic daemon (trafd) • VS daemon (vsd) • Web linker daemon (weblinkerd) • Web Tools daemon (webd) • ZONE daemon (zoned) KTRC Kernel RAS trace module. L2SS L2SYS error messages indicate problems with the Layer 2 System - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 54
interrupt service routine cable, they are in the Init state. After both switches receive HELLO messages, they move to the Database Exchange state, and so on. NBFSM states are Down (0), Init (1), Database Exchange (2), Database Acknowledge Wait (3), Database Wait (4), and Full (5). Indicates problems - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 55
as an SNMP agent). It also allows the switch to send traps to the defined and configured management station. Brocade switches support six management entities that can be configured to receive these traps. SPC messages indicate problems and informational updates associated with the security processor - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 56
if there are any problems during the firmwareDownload procedure. Most messages are informational only and are generated even during successful firmware download. For additional information, refer to the Fabric OS Administrator's Guide. These messages are generated by the switch driver module that - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 57
Log Messages AG Messages AG-1001 AG-1002 AG-1003 AG-1004 AG-1005 AG-1006 AG-1007 AG-1008 AG-1009 AG-1010 AG-1011 AG-1012 AG-1013 AG-1014 AG-1015 AG-1016 AG-1017 AG-1018 AG-1019 AG-1020 AG-1021 AG-1022 AG-1023 AG-1024 AG-1025 AG-1026 AG-1027 AG-1028 Fabric OS Message Reference 53-1002749-01 Chapter - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 58
2 AN Messages AG-1029 AG-1030 AG-1031 AG-1032 AG-1033 AG-1034 AG-1035 AG-1036 AG-1037 AG-1038 AG-1039 AG-1040 AG-1041 AG-1042 AG-1043 AG-1044 AN Messages AN-1001 AN-1002 AN-1003 AN-1004 AN-1005 AN-1010 AN-1011 AN-1012 AN-1013 ANV Messages ANV-1001 ANV-1002 ANV-1003 ANV-1004 ANV-1005 36 Fabric OS - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 59
ANV-1006 ANV-1007 ANV-1008 ANV-1015 ANV-1016 ANV-1028 AUTH Messages AUTH-1001 AUTH-1002 AUTH-1003 AUTH-1004 AUTH-1005 AUTH-1006 AUTH-1007 AUTH-1008 AUTH-1010 AUTH-1011 AUTH-1012 AUTH-1013 AUTH-1014 AUTH-1016 AUTH-1017 AUTH-1018 AUTH-1020 AUTH-1022 AUTH-1023 AUTH-1025 AUTH-1026 AUTH-1027 AUTH-1028 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 60
2 BKSW Messages AUTH-1033 AUTH-1034 AUTH-1035 AUTH-1036 AUTH-1037 AUTH-1038 AUTH-1039 AUTH-1040 AUTH-1041 AUTH-1042 AUTH-1043 AUTH-1044 AUTH-1045 AUTH-1046 AUTH-1047 BKSW Messages BKSW-1003 BL Messages BL-1000 BL-1001 BL-1002 BL-1003 BL-1004 BL-1006 BL-1007 BL-1008 BL-1009 BL-1010 BL-1011 BL-1012 BL - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 61
BL-1015 BL-1016 BL-1017 BL-1018 BL-1019 BL-1020 BL-1021 BL-1022 BL-1023 BL-1024 BL-1025 BL-1026 BL-1027 BL-1028 BL-1029 BL-1030 BL-1031 BL-1032 BL-1033 BL-1034 BL-1035 BL-1036 BL-1037 BL-1038 BL-1039 BL-1041 BL-1045 BL-1046 BL-1047 BL-1048 BL-1049 BL-1050 BL-1051 BL-1052 Fabric OS Message Reference - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 62
2 BLS Messages BLS Messages BLS-1000 BLS-1001 BLS-1002 BLS-1003 BLS-1004 BLS-1005 BM Messages BM-1001 BM-1002 BM-1003 BM-1004 BM-1005 BM-1006 BM-1007 BM-1008 BM-1009 BM-1010 BM-1053 BM-1054 BM-1055 BM-1056 BM-1058 C2 Messages C2-1001 C2-1002 C2-1004 C2-1006 C2-1007 C2-1008 C2-1009 C2-1010 40 Fabric - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 63
C2-1012 C2-1013 C2-1014 C2-1015 C2-1016 C2-1017 C2-1018 C2-1019 C2-1025 C2-1026 C2-1027 C2-1028 C3 Messages C3-1001 C3-1002 C3-1004 C3-1006 C3-1007 C3-1008 C3-1009 C3-1010 C3-1011 C3-1012 C3-1013 C3-1014 C3-1015 C3-1016 C3-1017 C3-1018 C3-1019 C3-1020 C3-1021 C3-1023 C3-1025 Fabric OS Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 64
2 CAL Messages C3-1026 C3-1027 C3-1028 CAL Messages CAL-1001 CCFG Messages CCFG-1001 CCFG-1002 CCFG-1003 CCFG-1004 CCFG-1005 CCFG-1006 CCFG-1007 CCFG-1008 CCFG-1009 CCFG-1010 CCFG-1011 CCFG-1012 CDR Messages CDR-1001 CDR-1002 CDR-1003 CDR-1004 CDR-1005 CDR-1006 CDR-1007 CDR-1008 CDR-1009 CDR-1010 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 65
CDR-1014 CDR-1015 CDR-1016 CDR-1017 CDR-1018 CDR-1019 CDR-1022 CDR-1028 CHS Messages CHS-1002 CHS-1003 CHS-1004 CHS-1005 CNM Messages CNM-1001 CNM-1002 CNM-1003 CNM-1004 CNM-1005 CNM-1006 CNM-1007 CNM-1008 CNM-1009 CNM-1010 CNM-1011 CNM-1012 CNM-1013 CNM-1014 CNM-1015 CNM-1016 CNM-1017 CNM-1018 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 66
2 CNM Messages CNM-1019 CNM-1020 CNM-1021 CNM-1022 CNM-1023 CNM-1024 CNM-1025 CNM-1026 CNM-1027 CNM-1028 CNM-1029 CNM-1030 CNM-1031 CNM-1032 CNM-1033 CNM-1034 CNM-1035 CNM-1036 CNM-1037 CNM-1038 CNM-1039 CNM-1040 CNM-1041 CNM-1042 CNM-1043 CNM-1044 CNM-1045 CNM-1046 CNM-1047 CNM-1048 CNM-1049 CNM- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 67
CNM-1054 CNM-1055 CNM-1056 CNM-1057 CNM-1058 CNM-1059 CNM-1060 CNM-1061 CNM-1062 CNM-3001 CNM-3002 CNM-3003 CNM-3004 CNM-3005 CNM-3006 CNM-3007 CNM-3008 CNM-3009 CNM-3010 CNM-3011 CNM-3012 CONF Messages CONF-1000 CONF-1001 CONF-1021 CONF-1023 CONF-1024 CONF-1030 CONF-1031 CONF-1032 CONF-1040 CONF- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 68
2 CTAP Messages CONF-1044 CTAP Messages CTAP-1001 CVLC Messages CVLC-1001 CVLC-1002 CVLC-1003 CVLC-1004 CVLC-1005 CVLC-1006 CVLC-1007 CVLC-1008 CVLC-1009 CVLC-1010 CVLC-1011 CVLC-1012 CVLC-1013 CVLC-1014 CVLC-1015 CVLC-1016 CVLC-1017 CVLC-1018 CVLC-1019 CVLC-1020 CVLC-1021 CVLC-1022 CVLC-1023 CVLC- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 69
CVLC-1029 CVLC-1030 CVLC-1031 CVLC-1032 CVLC-1033 CVLC-1034 CVLC-1035 CVLC-1039 CVLC-1041 CVLM Messages CVLM-1001 CVLM-1002 CVLM-1003 CVLM-1004 CVLM-1005 CVLM-1006 CVLM-1007 CVLM-1008 CVLM-1009 CVLM-1010 CVLM-1011 CVLM-1012 CVLM-1013 CVLM-1014 CVLM-1015 CVLM-1016 CVLM-3001 CVLM-3002 CVLM-3003 CVLM- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 70
2 DOT1 Messages CVLM-3009 CVLM-3010 CVLM-3011 CVLM-3012 CVLM-3013 CVLM-3014 CVLM-3015 CVLM-3016 CVLM-3017 CVLM-3018 CVLM-3019 CVLM-3020 CVLM-3021 CVLM-3022 CVLM-3023 CVLM-3024 CVLM-3025 CVLM-3026 CVLM-3027 CVLM-3028 DOT1 Messages DOT1-1001 DOT1-1002 DOT1-1003 DOT1-1004 DOT1-1005 DOT1-1006 DOT1-1007 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 71
ECC Messages ECC-1000 ECC-1001 EM Messages EM-1001 EM-1002 EM-1003 EM-1004 EM-1005 EM-1006 EM-1008 EM-1009 EM-1010 EM-1011 EM-1012 EM-1013 EM-1014 EM-1015 EM-1016 EM-1017 EM-1018 EM-1019 EM-1020 EM-1028 EM-1029 EM-1031 EM-1033 EM-1034 EM-1035 EM-1036 EM-1037 EM-1042 EM-1043 Fabric OS Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 72
2 ESS Messages EM-1044 EM-1045 EM-1046 EM-1047 EM-1048 EM-1049 EM-1050 EM-1051 EM-1057 EM-1058 EM-1059 EM-1060 EM-1061 EM-1062 EM-1063 EM-1064 EM-1065 EM-1066 EM-1067 EM-1068 EM-1069 EM-1070 EM-1071 EM-1072 EM-2003 ESS Messages ESS-1001 ESS-1002 ESS-1003 ESS-1004 ESS-1005 ESS-1008 ESS-1009 ESS-1010 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 73
ESW Messages ESW-1001 ESW-1002 ESW-1003 ESW-1004 ESW-1005 ESW-1006 ESW-1007 ESW-1008 EVMD Messages EVMD-1001 FABR Messages FABR-1001 FABR-1002 FABR-1003 FABR-1004 FABR-1005 FABR-1006 FABR-1007 FABR-1008 FABR-1009 FABR-1010 FABR-1011 FABR-1012 FABR-1013 FABR-1014 FABR-1015 FABR-1016 FABR-1017 FABR- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 74
2 FABS Messages FABR-1021 FABR-1022 FABR-1023 FABR-1024 FABR-1029 FABR-1030 FABR-1031 FABR-1032 FABR-1034 FABR-1035 FABR-1036 FABR-1037 FABR-1038 FABR-1039 FABR-1040 FABR-1041 FABR-1043 FABR-1044 FABR-1045 FABR-1046 FABR-1047 FABR-1048 FABR-1049 FABR-1050 FABR-1051 FABR-1052 FABR-1053 FABR-1054 FABR - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 75
FABS-1006 FABS-1007 FABS-1008 FABS-1009 FABS-1010 FABS-1011 FABS-1013 FABS-1014 FABS-1015 FBC Messages FBC-1001 FCMC Messages FCMC-1001 FCOE Messages FCOE-1001 FCOE-1002 FCOE-1003 FCOE-1004 FCOE-1005 FCOE-1006 FCOE-1007 FCOE-1009 FCOE-1010 FCOE-1012 FCOE-1014 FCOE-1015 FCOE-1016 FCOE-1017 FCOE-1019 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 76
2 FCPD Messages FCOE-1023 FCOE-1024 FCOE-1025 FCOE-1026 FCOE-1027 FCOE-1028 FCOE-1029 FCOE-1030 FCOE-1031 FCOE-1032 FCOE-1033 FCOE-1034 FCOE-1037 FCOE-1038 FCOE-1039 FCOE-1040 FCOE-1041 FCOE-1042 FCOE-1043 FCOE-1044 FCOE-1045 FCOE-1046 FCOE-1047 FCOE-1048 FCPD Messages FCPD-1001 FCPD-1002 FCPD-1003 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 77
FCPH-1004 FCPH-1005 FCR Messages FCR-1001 FCR-1002 FCR-1003 FCR-1004 FCR-1005 FCR-1006 FCR-1007 FCR-1008 FCR-1009 FCR-1010 FCR-1011 FCR-1012 FCR-1013 FCR-1015 FCR-1016 FCR-1018 FCR-1019 FCR-1020 FCR-1021 FCR-1022 FCR-1023 FCR-1024 FCR-1025 FCR-1026 FCR-1027 FCR-1028 FCR-1029 FCR-1030 FCR-1031 FCR- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 78
2 FCR Messages FCR-1034 FCR-1035 FCR-1036 FCR-1037 FCR-1038 FCR-1039 FCR-1040 FCR-1041 FCR-1042 FCR-1043 FCR-1048 FCR-1049 FCR-1053 FCR-1054 FCR-1055 FCR-1056 FCR-1057 FCR-1058 FCR-1059 FCR-1060 FCR-1061 FCR-1062 FCR-1063 FCR-1064 FCR-1065 FCR-1066 FCR-1067 FCR-1068 FCR-1069 FCR-1070 FCR-1071 FCR- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 79
FCR-1076 FCR-1077 FCR-1078 FCR-1079 FCR-1080 FCR-1081 FCR-1082 FCR-1083 FCR-1084 FCR-1085 FCR-1086 FCR-1087 FCR-1088 FCR-1089 FCR-1091 FCR-1092 FCR-1093 FCR-1094 FCR-1095 FCR-1096 FCR-1097 FCR-1098 FICN Messages FICN-1003 FICN-1004 FICN-1005 FICN-1006 FICN-1007 FICN-1008 FICN-1009 FICN-1010 FICN- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 80
2 FICN Messages FICN-1014 FICN-1015 FICN-1016 FICN-1017 FICN-1018 FICN-1019 FICN-1020 FICN-1021 FICN-1022 FICN-1023 FICN-1024 FICN-1025 FICN-1026 FICN-1027 FICN-1028 FICN-1029 FICN-1030 FICN-1031 FICN-1032 FICN-1033 FICN-1034 FICN-1035 FICN-1036 FICN-1037 FICN-1038 FICN-1039 FICN-1040 FICN-1041 FICN - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 81
FICN-1049 FICN-1050 FICN-1051 FICN-1052 FICN-1053 FICN-1054 FICN-1055 FICN-1056 FICN-1057 FICN-1058 FICN-1059 FICN-1060 FICN-1061 FICN-1062 FICN-1063 FICN-1064 FICN-1065 FICN-1066 FICN-1067 FICN-1068 FICN-1069 FICN-1070 FICN-1071 FICN-1072 FICN-1073 FICN-1074 FICN-1075 FICN-1076 FICN-1077 FICN-1078 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 82
2 FICN Messages FICN-1084 FICN-1085 FICN-1086 FICN-1087 FICN-1088 FICN-1089 FICN-1090 FICN-1091 FICN-1092 FICN-1093 FICN-1094 FICN-1095 FICN-1096 FICN-1097 FICN-1098 FICN-1099 FICN-1100 FICN-1101 FICN-1102 FICN-1103 FICN-1104 FICN-1105 FICN-1106 FICN-1107 FICN-1108 FICN-1109 FICN-1110 FICN-1111 FICN - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 83
FICN-1119 FICN-1120 FICN-1121 FICN-1122 FICN-2005 FICN-2006 FICN-2064 FICN-2065 FICN-2066 FICN-2082 FICN-2083 FICN-2085 FICN-2086 FICN-2087 FICU Messages FICU-1001 FICU-1002 FICU-1003 FICU-1004 FICU-1005 FICU-1006 FICU-1007 FICU-1008 FICU-1009 FICU-1010 FICU-1011 FICU-1012 FICU-1013 FICU-1017 FICU- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 84
2 FKLB Messages FICU-1023 FICU-1024 FKLB Messages FKLB-1001 FLOD Messages FLOD-1001 FLOD-1003 FLOD-1004 FLOD-1005 FLOD-1006 FSPF Messages FSPF-1001 FSPF-1002 FSPF-1003 FSPF-1005 FSPF-1006 FSPF-1007 FSPF-1008 FSPF-1009 FSPF-1010 FSPF-1011 FSPF-1012 FSS Messages FSS-1001 FSS-1002 FSS-1003 FSS-1004 FSS - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 85
FSS-1008 FSS-1009 FSS-1010 FSS-1011 FSSM Messages FSSM-1002 FSSM-1003 FSSM-1004 FW Messages FW-1001 FW-1002 FW-1003 FW-1004 FW-1005 FW-1006 FW-1007 FW-1008 FW-1009 FW-1010 FW-1011 FW-1012 FW-1033 FW-1034 FW-1035 FW-1036 FW-1037 FW-1038 FW-1039 FW-1040 FW-1041 FW-1042 FW-1043 Fabric OS Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 86
2 FW Messages FW-1044 FW-1045 FW-1046 FW-1047 FW-1048 FW-1049 FW-1050 FW-1051 FW-1052 FW-1053 FW-1054 FW-1113 FW-1114 FW-1115 FW-1116 FW-1117 FW-1118 FW-1119 FW-1120 FW-1121 FW-1122 FW-1123 FW-1124 FW-1125 FW-1126 FW-1127 FW-1128 FW-1129 FW-1130 FW-1131 FW-1132 FW-1133 FW-1134 FW-1135 FW-1136 64 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 87
FW-1137 FW-1138 FW-1139 FW-1140 FW-1160 FW-1161 FW-1162 FW-1163 FW-1164 FW-1165 FW-1166 FW-1167 FW-1168 FW-1169 FW-1170 FW-1171 FW-1172 FW-1173 FW-1174 FW-1175 FW-1176 FW-1177 FW-1178 FW-1179 FW-1180 FW-1181 FW-1182 FW-1183 FW-1184 FW-1185 FW-1186 FW-1187 FW-1188 FW-1189 FW-1190 Fabric OS Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 88
2 FW Messages FW-1191 FW-1192 FW-1193 FW-1194 FW-1195 FW-1196 FW-1197 FW-1198 FW-1199 FW-1200 FW-1201 FW-1202 FW-1203 FW-1204 FW-1205 FW-1206 FW-1207 FW-1216 FW-1217 FW-1218 FW-1219 FW-1240 FW-1241 FW-1242 FW-1243 FW-1244 FW-1245 FW-1246 FW-1247 FW-1248 FW-1249 FW-1250 FW-1251 FW-1272 FW-1273 66 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 89
FW-1274 FW-1275 FW-1296 FW-1297 FW-1298 FW-1299 FW-1300 FW-1301 FW-1302 FW-1303 FW-1304 FW-1305 FW-1306 FW-1307 FW-1308 FW-1309 FW-1310 FW-1311 FW-1312 FW-1313 FW-1314 FW-1315 FW-1316 FW-1317 FW-1318 FW-1319 FW-1320 FW-1321 FW-1322 FW-1323 FW-1324 FW-1325 FW-1326 FW-1327 FW-1328 Fabric OS Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 90
2 FW Messages FW-1329 FW-1330 FW-1331 FW-1332 FW-1333 FW-1334 FW-1335 FW-1336 FW-1337 FW-1338 FW-1339 FW-1340 FW-1341 FW-1342 FW-1343 FW-1344 FW-1345 FW-1346 FW-1347 FW-1348 FW-1349 FW-1350 FW-1351 FW-1352 FW-1353 FW-1354 FW-1355 FW-1356 FW-1357 FW-1358 FW-1359 FW-1360 FW-1361 FW-1362 FW-1363 68 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 91
FW-1364 FW-1365 FW-1366 FW-1367 FW-1368 FW-1369 FW-1370 FW-1371 FW-1372 FW-1373 FW-1374 FW-1375 FW-1376 FW-1377 FW-1378 FW-1379 FW-1400 FW-1401 FW-1402 FW-1403 FW-1404 FW-1405 FW-1406 FW-1407 FW-1408 FW-1424 FW-1425 FW-1426 FW-1427 FW-1428 FW-1429 FW-1430 FW-1431 FW-1432 FW-1433 Fabric OS Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 92
2 FW Messages FW-1434 FW-1435 FW-1436 FW-1437 FW-1438 FW-1439 FW-1440 FW-1441 FW-1442 FW-1443 FW-1444 FW-1445 FW-1446 FW-1447 FW-1448 FW-1500 FW-1501 FW-1502 FW-1510 FW-1511 FW-1512 FW-1513 FW-1514 FW-1515 FW-1516 FW-1517 FW-1518 FW-1519 FW-1520 FW-1521 FW-1522 FW-1523 FW-1524 FW-1525 FW-1526 70 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 93
FW-1527 FW-1528 FW-1529 FW-1530 FW-1531 FW-1532 FW-1533 FW-1534 FW-1535 FW-2000 FW-3010 FW-3011 FW-3012 FW-3013 FW-3014 FW-3015 FW-3016 FW-3017 FW-3018 FW-3019 FW-3020 FW-3021 FW-3022 HAM Messages HAM-1001 HAM-1002 HAM-1004 HAM-1005 HAM-1006 HAM-1007 HAM-1008 HAM-1009 HAM-1010 HAM-1011 Fabric OS - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 94
2 HAMK Messages HAM-1013 HAM-1014 HAMK Messages HAMK-1001 HAMK-1002 HAMK-1003 HAMK-1004 HIL Messages HIL-1101 HIL-1102 HIL-1103 HIL-1104 HIL-1105 HIL-1106 HIL-1107 HIL-1108 HIL-1201 HIL-1202 HIL-1203 HIL-1204 HIL-1206 HIL-1207 HIL-1208 HIL-1301 HIL-1302 HIL-1303 HIL-1304 HIL-1305 HIL-1306 HIL-1307 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 95
HIL-1310 HIL-1311 HIL-1401 HIL-1402 HIL-1403 HIL-1404 HIL-1501 HIL-1502 HIL-1503 HIL-1504 HIL-1505 HIL-1506 HIL-1507 HIL-1508 HIL-1509 HIL-1510 HIL-1511 HIL-1601 HIL-1602 HIL-1603 HIL-1605 HIL-1610 HIL-1611 HIL-1612 HIL-1613 HIL-1650 HLO Messages HLO-1001 HLO-1002 HLO-1003 HMON Messages HMON-1001 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 96
2 HSL Messages HSL Messages HSL-1000 HSL-1001 HSL-1002 HSL-1003 HSL-1004 HSL-1005 HSL-1006 HSL-1007 HTTP Messages HTTP-1001 HTTP-1002 HTTP-1003 IBD Messages IBD-1000 IPAD Messages IPAD-1000 IPAD-1001 IPAD-1002 IPAD-1003 IPAD-1004 IPS Messages IPS-1001 IPS-1002 IPS-1003 IPS-1004 IPS-1005 IPS-1006 IPS - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 97
ISNS Messages ISNS-1001 ISNS-1002 ISNS-1003 ISNS-1004 ISNS-1005 ISNS-1006 ISNS-1008 ISNS-1009 ISNS-1010 ISNS-1011 ISNS-1013 ISNS-1014 KAC Messages KAC-1002 KAC-1004 KAC-1006 KAC-1007 KAC-1008 KAC-1009 KAC-1010 KAC-1011 KAC-1012 KAC-1013 KAC-1014 KAC-1015 KAC-1016 KAC-1017 KSWD Messages KSWD-1001 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 98
2 KTRC Messages KTRC Messages KTRC-1001 KTRC-1002 KTRC-1003 KTRC-1004 KTRC-1005 L2SS Messages L2SS-1001 L2SS-1002 L2SS-1003 L2SS-1004 L2SS-1005 L2SS-1006 L2SS-1007 L2SS-1008 L3SS Messages L3SS-1004 LACP Messages LACP-1001 LACP-1002 LANCE Messages LANCE-1000 LFM Messages LFM-1001 LFM-1002 LFM-1003 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 99
LFM-1006 LOG Messages LOG-1000 LOG-1001 LOG-1002 LOG-1003 LOG-1004 LOG-1005 LOG-1006 LOG-1007 LOG-1008 LOG-1009 LOG-1010 LOG-1011 LSDB Messages LSDB-1001 LSDB-1002 LSDB-1003 LSDB-1004 MCAST_SS Messages MCAST_SS-1001 MCAST_SS-1002 MCAST_SS-1003 MCAST_SS-1004 MCAST_SS-1005 MCAST_SS-1006 MCAST_SS-1007 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 100
2 MFIC Messages MCAST_SS-1012 MCAST_SS-1013 MCAST_SS-1014 MCAST_SS-1015 MCAST_SS-1016 MCAST_SS-1017 MCAST_SS-1018 MCAST_SS-1019 MCAST_SS-1020 MFIC Messages MFIC-1001 MFIC-1002 MFIC-1003 MM Messages MM-1001 MPTH Messages MPTH-1001 MPTH-1002 MPTH-1003 MQ Messages MQ-1004 MQ-1005 MQ-1006 MS Messages MS - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 101
MS-1006 MS-1008 MS-1009 MS-1021 MS-1022 MS-1023 MS-1024 MS-1025 MS-1026 MS-1027 MS-1028 MS-1029 MS-1030 MSTP Messages MSTP-1001 MSTP-1002 MSTP-1003 MSTP-2001 MSTP-2002 MSTP-2003 MSTP-2004 MSTP-2005 MSTP-2006 NBFS Messages NBFS-1001 NBFS-1002 NBFS-1003 NBFS-1004 NS Messages NS-1001 NS-1002 Fabric OS - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 102
2 NSM Messages NS-1003 NS-1004 NS-1005 NS-1006 NS-1007 NS-1008 NS-1009 NS-1010 NS-1011 NS-1012 NSM Messages NSM-1001 NSM-1002 NSM-1003 NSM-1004 NSM-1005 NSM-1006 NSM-1007 NSM-1008 NSM-1009 NSM-1010 NSM-1011 NSM-1012 NSM-1013 NSM-1014 NSM-1015 NSM-1016 NSM-1017 NSM-1018 NSM-1019 NSM-1020 80 Fabric - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 103
ONMD Messages ONMD-1000 ONMD-1001 ONMD-1002 ONMD-1003 ONMD-1004 ONMD-1005 PDM Messages PDM-1001 PDM-1002 PDM-1003 PDM-1004 PDM-1005 PDM-1006 PDM-1007 PDM-1008 PDM-1009 PDM-1010 PDM-1011 PDM-1012 PDM-1013 PDM-1014 PDM-1017 PDM-1019 PDM-1020 PDM-1021 PDM-1022 PDM-1023 PDM-1024 PDM-1025 PDM-1026 Fabric - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 104
2 PDTR Messages PDTR Messages PDTR-1001 PDTR-1002 PLAT Messages PLAT-1000 PLAT-1001 PLAT-1002 PLAT-1003 PLAT-1004 PLAT-1072 PMGR Messages PMGR-1001 PMGR-1002 PMGR-1003 PMGR-1004 PMGR-1005 PMGR-1006 PMGR-1007 PMGR-1008 PMGR-1009 PMGR-1010 PMGR-1011 PORT Messages PORT-1003 PORT-1004 PORT-1005 PORT- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 105
PS Messages PS-1000 PS-1001 PS-1002 PS-1003 PS-1004 PS-1005 PS-1006 PS-1007 PS-1008 PS-1009 PS-1010 PSWP Messages PSWP-1001 PSWP-1002 PSWP-1003 PSWP-1004 PSWP-1005 PSWP-1006 PSWP-1007 RAS Messages RAS-1001 RAS-1002 RAS-1004 RAS-1005 RAS-1006 RAS-1007 RAS-2001 RAS-2002 RAS-2003 RAS-3001 RAS-3002 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 106
2 RCS Messages RAS-3003 RAS-3004 RCS Messages RCS-1001 RCS-1002 RCS-1003 RCS-1004 RCS-1005 RCS-1006 RCS-1007 RCS-1008 RCS-1009 RCS-1010 RCS-1011 RCS-1012 RCS-1013 RKD Messages RKD-1001 RKD-1002 RKD-1003 RKD-1004 RKD-1005 RMON Messages RMON-1001 RMON-1002 RPCD Messages RPCD-1001 RPCD-1002 RPCD-1003 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 107
RPCD-1005 RPCD-1006 RPCD-1007 RTE Messages RTE-1001 RTWR Messages RTWR-1001 RTWR-1002 RTWR-1003 SCN Messages SCN-1001 SCN-1002 SEC Messages SEC-1001 SEC-1002 SEC-1003 SEC-1005 SEC-1006 SEC-1007 SEC-1008 SEC-1009 SEC-1010 SEC-1016 SEC-1022 SEC-1024 SEC-1025 SEC-1026 SEC-1028 SEC-1029 SEC-1030 Fabric - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 108
2 SEC Messages SEC-1031 SEC-1032 SEC-1033 SEC-1034 SEC-1035 SEC-1036 SEC-1037 SEC-1038 SEC-1039 SEC-1040 SEC-1041 SEC-1042 SEC-1043 SEC-1044 SEC-1045 SEC-1046 SEC-1049 SEC-1050 SEC-1051 SEC-1052 SEC-1053 SEC-1054 SEC-1055 SEC-1056 SEC-1057 SEC-1059 SEC-1062 SEC-1063 SEC-1064 SEC-1065 SEC-1069 SEC- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 109
SEC-1075 SEC-1076 SEC-1077 SEC-1078 SEC-1079 SEC-1080 SEC-1081 SEC-1082 SEC-1083 SEC-1084 SEC-1085 SEC-1086 SEC-1087 SEC-1088 SEC-1089 SEC-1090 SEC-1091 SEC-1092 SEC-1093 SEC-1094 SEC-1095 SEC-1096 SEC-1097 SEC-1098 SEC-1099 SEC-1100 SEC-1101 SEC-1102 SEC-1104 SEC-1105 SEC-1106 SEC-1107 SEC-1108 SEC - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 110
2 SEC Messages SEC-1112 SEC-1113 SEC-1114 SEC-1115 SEC-1116 SEC-1117 SEC-1118 SEC-1119 SEC-1121 SEC-1122 SEC-1123 SEC-1124 SEC-1126 SEC-1130 SEC-1135 SEC-1136 SEC-1137 SEC-1138 SEC-1139 SEC-1142 SEC-1145 SEC-1146 SEC-1153 SEC-1154 SEC-1155 SEC-1156 SEC-1157 SEC-1158 SEC-1159 SEC-1160 SEC-1163 SEC- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 111
SEC-1168 SEC-1170 SEC-1171 SEC-1172 SEC-1173 SEC-1174 SEC-1175 SEC-1176 SEC-1180 SEC-1181 SEC-1182 SEC-1183 SEC-1184 SEC-1185 SEC-1186 SEC-1187 SEC-1188 SEC-1189 SEC-1190 SEC-1191 SEC-1192 SEC-1193 SEC-1194 SEC-1195 SEC-1196 SEC-1197 SEC-1198 SEC-1199 SEC-1200 SEC-1201 SEC-1202 SEC-1203 SEC-1250 SEC - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 112
2 SEC Messages SEC-1300 SEC-1301 SEC-1302 SEC-1303 SEC-1304 SEC-1305 SEC-1306 SEC-1307 SEC-1308 SEC-1309 SEC-1310 SEC-1311 SEC-1312 SEC-1313 SEC-1314 SEC-1315 SEC-1316 SEC-1317 SEC-1318 SEC-1319 SEC-1320 SEC-1321 SEC-1322 SEC-1323 SEC-1324 SEC-1325 SEC-1326 SEC-1327 SEC-1328 SEC-1329 SEC-1330 SEC- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 113
SEC-1335 SEC-1336 SEC-1337 SEC-1338 SEC-1339 SEC-3035 SEC-3036 SEC-3037 SEC-3038 SEC-3039 SEC-3050 SEC-3051 SEC-3061 SEC-3062 SEC-3063 SEC-3064 SEC-3065 SEC-3066 SEC-3067 SEC-4001 SFLO Messages SFLO-1001 SFLO-1002 SFLO-1003 SFLO-1004 SFLO-1005 SFLO-1006 SFLO-1007 SFLO-1008 SNMP Messages SNMP-1001 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 114
2 SPC Messages SNMP-1003 SNMP-1004 SNMP-1005 SNMP-1006 SNMP-1009 SPC Messages SPC-1001 SPC-1002 SPC-1003 SPC-2001 SPC-2002 SPC-2003 SPC-2004 SPC-2005 SPC-2006 SPC-2007 SPC-2008 SPC-2009 SPC-2010 SPC-2011 SPC-2012 SPC-2013 SPC-2014 SPC-2040 SPC-2041 SPC-2042 SPC-2043 SPC-2044 SPC-3001 SPC-3002 SPC- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 115
SPC-3007 SPC-3008 SPC-3009 SPC-3010 SPC-3011 SPC-3012 SPC-3013 SPC-3014 SPC-3015 SPM Messages SPM-1001 SPM-1002 SPM-1003 SPM-1004 SPM-1005 SPM-1006 SPM-1007 SPM-1008 SPM-1009 SPM-1010 SPM-1011 SPM-1012 SPM-1013 SPM-1014 SPM-1015 SPM-1016 SPM-3001 SPM-3002 SPM-3003 SPM-3004 SPM-3005 SPM-3006 SPM-3007 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 116
2 SS Messages SPM-3009 SPM-3010 SPM-3011 SPM-3012 SPM-3013 SPM-3014 SPM-3015 SPM-3016 SPM-3017 SPM-3018 SPM-3019 SPM-3020 SPM-3021 SPM-3022 SPM-3023 SPM-3024 SPM-3025 SPM-3026 SPM-3027 SPM-3028 SPM-3029 SS Messages SS-1000 SS-1001 SS-1002 SS-1003 SS-1004 SS-1005 SS-1006 SS-1007 SS-1008 SS-1009 SS- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 117
SS-1012 SSMD Messages SSMD-1001 SSMD-1002 SSMD-1003 SSMD-1004 SSMD-1005 SSMD-1006 SSMD-1007 SSMD-1008 SSMD-1200 SSMD-1201 SSMD-1202 SSMD-1203 SSMD-1204 SSMD-1205 SSMD-1206 SSMD-1207 SSMD-1208 SSMD-1209 SSMD-1210 SSMD-1211 SSMD-1212 SSMD-1213 SSMD-1214 SSMD-1215 SSMD-1216 SSMD-1217 SSMD-1300 SSMD- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 118
2 SULB Messages SSMD-1306 SSMD-1307 SSMD-1308 SSMD-1309 SSMD-1310 SSMD-1311 SSMD-1312 SSMD-1313 SSMD-1314 SSMD-1315 SSMD-1316 SSMD-1317 SSMD-1318 SULB Messages SULB-1001 SULB-1002 SULB-1003 SULB-1004 SULB-1005 SULB-1006 SULB-1007 SULB-1008 SULB-1009 SULB-1010 SULB-1011 SULB-1017 SULB-1018 SULB-1020 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 119
SULB-1030 SULB-1031 SULB-1032 SULB-1033 SULB-1034 SULB-1035 SULB-1036 SULB-1037 SULB-1038 SULB-1039 SULB-1040 SULB-1041 SULB-1042 SULB-1043 SULB-1044 SWCH Messages SWCH-1001 SWCH-1002 SWCH-1003 SWCH-1004 SWCH-1005 SWCH-1006 SWCH-1007 SWCH-1008 SWCH-1009 SWCH-1010 SWCH-1011 SWCH-1012 SWCH-1013 SWCH- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 120
2 SYSC Messages SWCH-1019 SWCH-1020 SWCH-1021 SWCH-1022 SWCH-1023 SWCH-1024 SWCH-1025 SWCH-1026 SYSC Messages SYSC-1001 SYSC-1002 SYSC-1004 SYSC-1005 SYSM Messages SYSM-1001 SYSM-1002 SYSM-1003 SYSM-1004 SYSM-1005 SYSM-1006 SYSM-1007 TAPE Messages TAPE-1001 TRCE Messages TRCE-1001 TRCE-1002 TRCE- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 121
TRCE-1007 TRCE-1008 TRCE-1009 TRCE-1010 TRCE-1011 TRCE-1012 TRCE-1013 TRCK Messages TRCK-1001 TRCK-1002 TRCK-1003 TRCK-1004 TRCK-1005 TRCK-1006 TS Messages TS-1001 TS-1002 TS-1006 TS-1007 TS-1008 UCST Messages UCST-1003 UCST-1007 UCST-1020 UCST-1021 UCST-1022 UCST-1023 UCST-1024 UCST-1026 UCST-1027 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 122
2 UPTH Messages UPTH Messages UPTH-1001 UPTH-1002 VDR Messages VDR-2001 VS Messages VS-1001 VS-1002 VS-1003 VS-1004 VS-1005 VS-1006 VS-1007 VS-1008 WEBD Messages WEBD-1001 WEBD-1002 WEBD-1004 WEBD-1005 WEBD-1006 WEBD-1007 WEBD-1008 XTUN Messages XTUN-1000 XTUN-1001 XTUN-1002 XTUN-1003 XTUN-1004 XTUN - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 123
XTUN-1006 XTUN-1007 XTUN-1996 XTUN-1997 XTUN-1998 XTUN-1999 XTUN-2000 XTUN-2001 XTUN-2002 XTUN-2003 XTUN-2004 XTUN-2005 XTUN-2006 XTUN-2007 XTUN-2008 XTUN-2009 XTUN-2010 XTUN-2011 XTUN-2020 XTUN-2021 XTUN-2022 XTUN-2023 XTUN-2024 XTUN-2025 ZEUS Messages ZEUS-1001 ZEUS-1002 ZEUS-1003 ZEUS-1004 ZEUS- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 124
2 ZONE Messages ZONE Messages ZONE-1002 ZONE-1003 ZONE-1004 ZONE-1007 ZONE-1010 ZONE-1013 ZONE-1015 ZONE-1017 ZONE-1019 ZONE-1022 ZONE-1023 ZONE-1024 ZONE-1026 ZONE-1027 ZONE-1028 ZONE-1029 ZONE-1034 ZONE-1036 ZONE-1037 ZONE-1038 ZONE-1039 ZONE-1040 ZONE-1041 ZONE-1042 ZONE-1043 ZONE-1044 ZONE-1045 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 125
ZONE-1059 ZONE-1060 ZONE-1061 ZONE-1062 ZONE Messages 2 Fabric OS Message Reference 103 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 126
2 ZONE Messages 104 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 127
Audit Messages AG Messages AG-1033 AG-1034 AG-1035 AG-1036 AG-1037 AN Messages AN-1003 AN-1004 AN-1005 AN-1006 AN-1010 AN-1011 AN-1012 AN-1013 AUTH Messages AUTH-1045 AUTH-1046 AUTH-1047 AUTH-3001 AUTH-3002 AUTH-3003 AUTH-3004 AUTH-3005 AUTH-3006 AUTH-3007 AUTH-3008 Fabric OS Message Reference 53- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 128
3 BLS Messages BLS Messages BLS-1002 BLS-1003 CCFG Messages CCFG-1002 CCFG-1003 CCFG-1013 CNM Messages CNM-3001 CNM-3002 CNM-3003 CNM-3004 CNM-3005 CNM-3006 CNM-3007 CNM-3008 CNM-3009 CNM-3010 CNM-3011 CNM-3012 CONF Messages CONF-1000 CONF-1020 CONF-1022 CONF-1042 CONF-1043 CONF-1044 CVLM Messages - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 129
CVLM-3002 CVLM-3003 CVLM-3004 CVLM-3005 CVLM-3006 CVLM-3007 CVLM-3008 CVLM-3009 CVLM-3010 CVLM-3011 CVLM-3012 CVLM-3013 CVLM-3014 CVLM-3015 CVLM-3016 CVLM-3017 CVLM-3018 CVLM-3019 CVLM-3020 CVLM-3021 CVLM-3022 CVLM-3023 CVLM-3024 CVLM-3025 CVLM-3026 CVLM-3027 CVLM-3028 ESS Messages ESS-1008 ESS-1009 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 130
3 FICU Messages FICU Messages FICU-1011 FICU-1012 FICU-1019 FICU-1020 FICU-1021 FW Messages FW-1202 FW-1274 FW-1402 FW-1404 FW-1405 FW-1406 FW-3001 HAM Messages HAM-1015 HTTP Messages HTTP-1002 HTTP-1003 IPAD Messages IPAD-1002 LOG Messages LOG-1005 LOG-1006 LOG-1007 LOG-1008 LOG-1011 108 Fabric OS - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 131
MS Messages MS-1027 MS-1028 MS-1029 MS-1030 PMGR Messages PMGR-1001 PMGR-1003 PORT Messages PORT-1006 PORT-1007 PORT-1008 PORT-1009 RAS Messages RAS-2001 RAS-2002 RAS-2003 RAS-3005 SEC Messages SEC-1113 SEC-1114 SEC-1337 SEC-3001 SEC-3002 SEC-3003 SEC-3004 SEC-3005 SEC-3006 SEC-3007 Fabric OS - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 132
3 SEC Messages SEC-3008 SEC-3009 SEC-3010 SEC-3011 SEC-3012 SEC-3013 SEC-3014 SEC-3015 SEC-3016 SEC-3017 SEC-3018 SEC-3019 SEC-3020 SEC-3021 SEC-3022 SEC-3023 SEC-3024 SEC-3025 SEC-3026 SEC-3027 SEC-3028 SEC-3029 SEC-3030 SEC-3031 SEC-3032 SEC-3033 SEC-3034 SEC-3035 SEC-3036 SEC-3037 SEC-3038 SEC- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 133
SEC-3047 SEC-3048 SEC-3049 SEC-3050 SEC-3051 SEC-3061 SEC-3062 SEC-3063 SEC-3064 SEC-3065 SEC-3066 SEC-3067 SEC-4001 SNMP Messages SNMP-1004 SNMP-1005 SNMP-1006 SNMP-1009 SPM Messages SPM-3001 SPM-3002 SPM-3003 SPM-3004 SPM-3005 SPM-3006 SPM-3007 SPM-3008 SPM-3009 SPM-3010 SPM-3011 SPM-3012 SPM-3013 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 134
3 SULB Messages SPM-3014 SPM-3015 SPM-3016 SPM-3017 SPM-3018 SPM-3019 SPM-3020 SPM-3021 SPM-3022 SPM-3023 SPM-3024 SPM-3025 SPM-3026 SPM-3027 SPM-3028 SPM-3029 SULB Messages SULB-1001 SULB-1002 SULB-1003 SULB-1004 SULB-1009 SULB-1010 SULB-1017 SULB-1018 SULB-1020 SULB-1021 SULB-1023 SULB-1024 SULB- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 135
SULB-1034 SULB-1035 SULB-1037 SULB-1038 SULB-1039 SULB-1040 SULB-1041 SULB-1042 SWCH Messages SWCH-1012 SWCH-1013 SWCH-1014 UCST Messages UCST-1021 UCST-1022 UCST-1023 UCST-1024 UCST-1026 UCST-1027 ZONE Messages ZONE-3001 ZONE-3002 ZONE-3003 ZONE-3004 ZONE-3005 ZONE-3006 ZONE-3007 ZONE-3008 ZONE- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 136
3 ZONE Messages ZONE-3012 ZONE-3013 ZONE-3014 ZONE-3015 ZONE-3016 ZONE-3017 ZONE-3018 ZONE-3019 ZONE-3020 ZONE-3021 ZONE-3022 ZONE-3023 ZONE-3024 ZONE-3025 ZONE-3026 114 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 137
FFDC Messages ANV Messages ANV-1002 AUTH Messages AUTH-1014 AUTH-1044 BKSW Messages BKSW-1003 BL Messages BL-1002 BL-1003 BL-1004 BL-1008 BL-1009 BL-1011 BL-1016 BL-1020 BLS Messages BLS-1000 BLS-1001 BM Messages BM-1003 BM-1053 Fabric OS Message Reference 53-1002749-01 Chapter 4 115 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 138
4 C2 Messages C2 Messages C2-1002 C2-1012 C3 Messages C3-1002 C3-1012 CDR Messages CDR-1002 CHS Messages CHS-1002 EM Messages EM-1001 EM-1002 EM-1003 EM-1004 EM-1005 EM-1006 EM-1008 EM-1009 EM-1010 EM-1011 EM-1012 EM-1018 EM-1020 EM-1028 EM-1068 EM-1071 EM-1072 116 Fabric OS Message Reference 53- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 139
FABR Messages FABR-1011 FABR-1013 FABR-1019 FABR-1020 FABR-1021 FABR-1022 FABR-1031 FABR-1054 FABS Messages FABS-1001 FCMC Messages FCMC-1001 FCPH Messages FCPH-1001 FLOD Messages FLOD-1004 HAM Messages HAM-1001 HAM-1006 HAM-1007 HAM-1008 HAM-1009 HAM-1011 HAMK Messages HAMK-1001 Fabric OS Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 140
4 HIL Messages HIL Messages HIL-1107 HIL-1108 HIL-1502 HIL-1503 HIL-1506 HIL-1507 HIL-1508 HIL-1509 HIL-1602 HIL-1603 HIL-1611 HLO Messages HLO-1001 HLO-1002 HMON Messages HMON-1001 KSWD Messages KSWD-1001 KSWD-1002 LFM Messages LFM-1004 LOG Messages LOG-1001 LOG-1002 LSDB Messages LSDB-1003 118 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 141
MPTH Messages MPTH-1001 MPTH-1002 NBFS Messages NBFS-1002 PDM Messages PDM-1017 PLAT Messages PLAT-1000 PLAT-1003 PLAT-1004 PLAT-1072 PS Messages PS-1000 RAS Messages RAS-1004 RAS-1005 RCS Messages RCS-1012 RCS-1013 SCN Messages SCN-1001 SCN-1002 Fabric OS Message Reference 53-1002749-01 MPTH - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 142
4 SNMP Messages SNMP Messages SNMP-1004 SYSC Messages SYSC-1001 SYSC-1002 SYSM Messages SYSM-1001 SYSM-1005 SYSM-1006 TRCE Messages TRCE-1008 UCST Messages UCST-1007 WEBD Messages WEBD-1008 ZEUS Messages ZEUS-1002 120 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 143
Guide for specific AG-compatibility requirements. • On non-Brocade switches, refer to the manufacturer's documentation to determine whether the switch supports NPIV and how to enable NPIV on these types of switches contact your switch service provider. Fabric OS Message Reference 121 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 144
not get blocked between two fabrics, although it is not a supported configuration. Recommended Action Configure two or more N_Ports to connect FTP transfers; then execute the supportSave command and contact your switch service provider. AG-1005 Message FDISC response was dropped because F_Port - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 145
N_Port connected to the fabric switch is not online. The Access Gateway N_Port and the fabric switch port. AG-1008 Message Invalid Probable Cause Indicates that the fabric switch management server did not accept the Check the configuration of the fabric switch connected to the Access Gateway. If - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 146
, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AG-1010 Message Sending PLOGI failed on N_Port . Message Type LOG Severity WARNING Probable Cause Indicates that there - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 147
persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AG-1013 Message F_Ports mapped to N_Port failed over to other N_Port(s). Message Type LOG Severity INFO Probable - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 148
persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AG-1016 Message Failing over F_Ports mapped to N_Port to other N_Port(s). Message Type LOG Severity INFO Probable - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 149
WARNING Probable Cause Indicates that failover across port groups is not supported. Recommended Action Check whether an alternate N_Port is configured in Indicates that F_Port-to-N_Port mapping has been changed because the switch has come online or some new N_Ports or F_Ports have come online - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 150
. Message Type LOG Severity WARNING Probable Cause Indicates that failover across N_Ports connected to different fabrics is not supported. Recommended Action Change the preferred N_Port settings of the specified F_Port using the ag --prefset command. Choose the preferred N_Port so that it - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 151
the login request. Recommended Action Execute the configure command on the Access Gateway switch and increase the number of allowed logins on the specified port. If the ; then execute the supportSave command and contact your switch service provider. Fabric OS Message Reference 129 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 152
enabled on the specified port. Recommended Action Execute the portCfgNpivPort command on the Access Gateway switch to enable the NPIV capability on the port. AG-1028 Message Device with Port WWN tried to perform fabric login through port , without having access permission - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 153
AG-1030 5 AG-1030 Message N_Port (ID: ) has been determined to be unreliable. Message Type LOG Severity WARNING Probable Cause Indicates that the port goes online and offline often and therefore the port is marked as unreliable. Recommended Action No action is required. The port - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 154
5 AG-1033 AG-1033 Message F_Port to N_Port mapping has been updated for N_Port (). Message Type AUDIT | LOG Class CFG Severity INFO Probable Cause Indicates that the F_Ports mapped to an N_Port have changed and the configuration file has been updated. Recommended Action No action is - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 155
to the Access Gateway Administrator's Guide for the supported configuration. AG-1037 Message Trunked N_Port () going offline. If switchshow CLI for the connected fabric switch port displays Persistently disabled: Area has been acquired, then check cabling: all trunked ports should be - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 156
port was toggled. Check EE monitor configuration as it might not be functional. Message Type LOG Severity WARNING Probable Cause Indicates that N_Port ID virtualization (NPIV) assigns a new port ID (PID) each time the same port is disabled and then re-enabled. As the PID has changed, the end-to - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 157
switch service provider. AG-1043 Message Authentication cannot be negotiated with the connected switch the edge switch connected to Access Gateway is using firmware earlier support authentication has tried to log in to the switch when the device authentication policy is in ON status on the switch - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 158
. Restart or power cycle the switch. AN-1002 Message Failed to initialize; rc = . Message Type LOG Severity ERROR Probable Cause Indicates that the initialization of the "trafd" daemon has failed. Recommended Action Download a new firmware version using the firmwareDownload command - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 159
device for the source of the latency. If the port is a long-distance E_Port, make sure that there are enough buffer credits to service the link distance. AN-1004 Message Congestion bottleneck on port /. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 160
whether there is complete credit loss on a virtual channel (VC) at the specified port are used by port mirroring. Recommended Action Contact your switch service provider for assistance. AN-1012 Message Credits did not return from other end. Complete loss of credits on a VC on slot - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 161
AN-1013 5 AN-1013 Message Performed link reset to recover the port credits on slot port . Message Type LOG | AUDIT Class FABRIC Severity INFO Probable Cause Indicates a credit loss. Recommended Action The port is recovered. No action is - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 162
, and the Fibre Channel cable is not faulty. Replace the SFP transceivers or the cable, if necessary. ANV-1002 a non-bladed system, execute the fastBoot command on the switch. ANV-1003 Message S,C: HW ASIC problem persists, replace the blade. 140 Fabric OS - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 163
memory allocation failure in the software. Recommended Action Restart the system at the next maintenance window. If the problem persists, replace the switch or contact your switch service provider. ANV-1006 Message S,C: HW ASIC Chip fault. Type = 0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 164
. Recommended Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. ANV-1008 Message S,C: MAC-VID classifier table is full. No space for new entry - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 165
the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. ANV-1028 Message Detected excessive Link resets on the the small form-factor pluggable (SFP) transceiver or the cable on the peer port to which this port is connected. Fabric OS Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 166
persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AUTH-1003 Message type has been successfully set to . Message Type LOG Severity INFO Probable Cause - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 167
Recommended Action Execute the firmwareDownload command to reinstall the firmware. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AUTH-1006 Message Failed to open - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 168
local switch supports the Fibre problem with the Secure Fabric OS. Recommended Action Reboot or power cycle the switch . If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 169
; then execute the supportSave command and contact your switch service provider. AUTH-1012 Message Authentication is because the remote entity does not support authentication. Recommended Action Verify the hash authentication request. Usually this problem is transient. The authentication - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 170
using the supportShow command, and contact your switch service provider. AUTH-1017 Message Invalid value to start authentication request: port , operation code . Message Type LOG Severity ERROR Probable Cause Indicates an internal problem with the Secure Fabric OS - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 171
Type LOG Severity ERROR Probable Cause Indicates an internal problem with the Secure Fabric OS. Recommended Action Reinitialize automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AUTH-1020 Message Failed to create timer for authentication: - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 172
up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AUTH-1025 Message Failed to get during - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 173
execute the supportSave command and contact your switch service provider. AUTH-1027 Message Failed to select This indicates that the local switch does not support the specified authentication value. the system is low on memory. Usually this problem is transient. The authentication may fail. The - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 174
get a particular authentication value at a certain phase. Usually this problem is transient. The authentication may fail. The Data type is automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AUTH-1031 Message Failed to retrieve secret value: port - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 175
automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AUTH-1032 Message Failed to generate for in authentication protocols to prevent replay attacks. Usually this problem is transient. The authentication may fail. Recommended Action - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 176
service provider. AUTH-1036 Message Invalid state for : port . Message Type LOG Severity ERROR Probable Cause Indicates that the switch received an unexpected authentication message. Usually this problem is transient. The authentication may - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 177
, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AUTH-1038 Message Failed to retrieve certificate during : port . Message Type LOG Severity ERROR - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 178
persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AUTH-1042 Message Port has been disabled, because authentication failed with code '' and explanation - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 179
supportSave command and contact your switch service provider. AUTH-1043 Message be defaulted to OFF, and the switch will has been disabled as a result. This problem may be transient due to the system CPU cable may have caused the failure. Recommended Action Check the SFP transceiver and the cable - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 180
execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AUTH-1046 Message has been successfully completed. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 181
AUTH-3001 5 AUTH-3001 Message Event: , Status: success, Info: type has been changed from [] to []. Message Type AUDIT Class SECURITY Severity INFO Probable Cause Indicates that an authentication configuration value was set to a specified value. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 182
then enable the port using the portEnable command. AUTH-3005 Message Event: , Status: failed, Info: Rejecting authentication request on port because switch policy is turned OFF. Message Type AUDIT Class SECURITY Severity INFO Probable Cause Indicates that the local - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 183
persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. AUTH-3007 Message Event: , Status: failed, Info: Port disabled due to receiving an authentication reject - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 184
signal abort (SIGABRT). Recommended Action Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. 162 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 185
Severity INFO Probable Cause Indicates that the switch has completed initializing the ports. Recommended Action problems. Additional blade fault messages precede and follow this error, providing more information. Refer to other error messages for recommended action. If the message persists, replace - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 186
cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware problems. If the message persists, replace the blade. BL-1006 Message Blade NOT faulted. Peer blade - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 187
cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware problems. If the message persists, replace the blade. BL-1009 Message Blade in slot timed out initializing the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 188
blade's ejector switch cycled to run POST and verify that the blade does not have any hardware problems. If the message persists, replace the blade. for a faulty cable, small form-factor pluggable (SFP) transceiver, or device attached to the specified port. On a bladed switch, execute the diagPost - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 189
a faulty cable, small form-factor pluggable (SFP) transceiver, or device attached to the specified port. On a bladed switch, run the slotPowerOff and slotPowerOn commands to power cycle the blade. On a non-bladed switch, reboot or power cycle the switch. If the message persists, replace the blade - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 190
not have any hardware problems. On a non-bladed switch, execute the reboot command to restart the switch. If there is a hardware error, the slotPowerOff or slotPowerOn fails on the bladed switch, or errors are encountered again, replace the blade or the (non-bladed) switch. BL-1015 Message bport - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 191
the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware problems. If the message persists, replace the blade. BL-1017 Message Slot Initializing... Message Type LOG Severity - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 192
to initialize the application-specific integrated circuit (ASIC) chips. Recommended Action Reboot or power cycle the switch. If the message persists, replace the switch. BL-1021 Message Retry , internal port retry initialization, - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 193
error messages for recommended action. If the message persists, replace the switch. BL-1023 Message Blade in slot was as part of the firmware upgrade. Message Type LOG Severity INFO Probable Cause Indicates that a recent firmware upgrade caused the blade firmware to be upgraded - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 194
of the firmware upgrade. Message Type LOG Severity INFO Probable Cause Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded Execute the supportSave command and then reboot switch. If the problem persists, replace the switch. BL-1027 Message Blade in slot < - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 195
. If the message persists, replace the switch. BL-1029 Message All ports on the switch will be reset as part of the firmware upgrade. Message Type LOG Severity INFO Probable Cause Indicates that a recent firmware upgrade caused the switch internal processor firmware to be upgraded and resulted - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 196
power cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware problems. If the message persists, replace the blade. BL-1033 Message (slot ,bitmap 0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 197
BL-1034 5 BL-1034 Message Slot FC Initialization completed. Message Type LOG Severity INFO Probable Cause Indicates that the slot has completed initializing the Fibre Channel (FC) ports. Recommended Action No action is required. BL-1035 Message Slot iSCSI port < - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 198
have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware problems. Additional blade fault messages software version. Recommended Action Reboot the switch. If the message persists, replace the switch. BL-1039 Message Inconsistent FPGA image version - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 199
blade does not support dynamic area mode on the default switch. Recommended Action supported only by a certain type of blade (FC8-64), but it can be inserted in other blades. Recommended Action Replace problems accessing the i2c accessible data> (). Try reseating or replacing - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 200
. Message Type LOG Severity WARNING Probable Cause Indicates that the interop mode is turned on in the default switch while powering on the FCoE blade. Recommended Action Disable the interop mode using the interopmode command; then execute the slotPowerOff and slotPowerOn commands on the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 201
switch service provider for upgrade instructions. BL-1051 Message Incompatible Blade Processor FPGA version with FOS7.0 firmware on 7800. Contact support for upgrade instructions on the Brocade 7800 switch. Recommended Action Contact your switch service provider for upgrade instructions. BL- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 202
| FFDC Severity CRITICAL Probable Cause Indicates that a Federal Information Protection Standard (FIPS) failure has occurred and requires faulting the blade or switch. Recommended Action Retry the command. BLS-1002 Message An IPsec/IKE policy was added. Message Type AUDIT | LOG Class CFG - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 203
the Fabric OS version on the remote end of the tunnel does not support Tape Read Pipelining. Recommended Action No action is required. BLS-1005 Message not deteriorated, and the Fibre Channel cable is not faulty. Replace the SFP transceivers or the cable if necessary. Fabric OS Message Reference - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 204
The problem can be corrected by changing the firmware version on either the CP or on the AP blade. You can modify the firmware version on the CP blade by using the firmwareDownload command. Refer to the release notes to determine whether a non-disruptive firmware download is supported between - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 205
upgrade. • The blade was recently inserted and had a different version of the firmware loaded. Recommended Action No action is required. The blade will automatically download the updated firmware. BM-1005 Message Firmwaredownload timed-out for blade in slot . Faulting blade. Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 206
to recover the blade. BM-1009 Message Firmwaredownload timed-out for application processor. Faulting switch. Message Type LOG Severity WARNING Probable Cause Indicates that the firmware download on the application processor (AP) blade failed. Recommended Action Execute the slotPowerOff and - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 207
CP and Application Processor. Faulting switch. Message Type LOG | FFDC firmware due to a firmware upgrade. • The blade was recently inserted and had a different version of the firmware loaded. Recommended Action No action is required. The blade will automatically download the updated firmware - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 208
5 BM-1055 BM-1055 Message Firmwaredownload timed-out for AP. Faulting switch. Message Type LOG Severity WARNING Probable Cause Indicates that firmware download on the application processor (AP) blade has failed. Recommended Action Execute the slotPowerOff and slotPowerOn commands or reseat - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 209
not faulty. Replace the SFP transceivers or the cable if necessary. C2-1002 Message Port chip faulted due to an internal error. Message Type LOG | FFDC Severity ERROR Probable Cause Indicates an internal error. All the ports on the blade or switch will be disrupted. Recommended - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 210
, the C2-1010 message will be generated identifying the failing field-replaceable unit (FRU). Recommended Action No action is required. C2-1007 as it is not supported under this configuration Message Type LOG Severity WARNING Probable Cause Indicates that quality of service (QoS) will be - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 211
Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. C2-1012 Message S,P(): Link Timeout on internal port ftx= - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 212
Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. C2-1015 Message Port re-initialized due to Link Reset failure on internal Port S,P( - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 213
. Recommended Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. C2-1017 Message Blade in Slot failed due to unavailability of ports in the internal trunk - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 214
that the device is returning the wrong number of receiver-ready (R_RDY) frames. Recommended Action When this error is observed persistently, replace the device. C2-1026 Message S,P(): Faulting F_port due to extra credit detected:ftx= curr_cred - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 215
the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. C2-1028 Message Detected excessive Link resets on the the small form-factor pluggable (SFP) transceiver or the cable on the peer port to which this port is connected. Fabric OS Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 216
is not faulty. Replace the SFP transceivers or the cable if necessary. C3-1002 Message Port chip failed due to an internal error. Message Type LOG | FFDC Severity ERROR Probable Cause Indicates an internal error. All the ports on the blade or switch will be disrupted. Recommended - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 217
number>): best effort QoS will be turned off at next port state change as it is not supported under this configuration. Message Type LOG Severity WARNING Probable Cause Indicates that quality of service (QoS) will be turned off automatically at the next port state change because best effort QoS - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 218
. Recommended Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. C3-1011 Message Detected a complete loss of credit on internal back-end VC: Slot , Port - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 219
the link is reset. Recommended Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. Fabric OS Message Reference 197 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 220
Recommended Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. C3-1016 Message Port is faulted due to port re-initialization failure on internal Port S,P - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 221
. Recommended Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. C3-1019 Message S,C: HW ASIC Chip TXQ FID parity error threshold reached type = 0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 222
Action When this error occurs, the software will automatically recover from the error and no action is required. However, if the problem persists, replace the blade. C3-1023 Message Single RDY/Frame Loss detected and recovered on Slot ,Port ( - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 223
the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. C3-1028 Message Detected excessive Link resets on the the small form-factor pluggable (SFP) transceiver or the cable on the peer port to which this port is connected. Fabric OS Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 224
5 CAL-1001 CAL Messages CAL-1001 Message Switch offline requested by remote domain . Message Type LOG Severity INFO Probable Cause Indicates that the specified remote domain requested the local domain to - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 225
the initialization of a module within the Converged Enhanced Ethernet (CEE) configuration management daemon has failed. Recommended Action Download a new firmware version using the firmwareDownload command. CCFG-1002 Message Started loading CEE system configuration. Message Type AUDIT | LOG - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 226
5 CCFG-1004 CCFG-1004 Message Configuration replay failed due to missing system startup configuration file. Message Type LOG Severity ERROR Probable Cause Indicates that the startup configuration file has been moved or deleted and therefore replaying the system configuration has failed. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 227
CCFG-1008 5 Recommended Action No action is required. CCFG-1008 Message CMSH init failed: . Message Type LOG Severity ERROR Probable Cause Indicates that the CEE Management Shell (CMSH) initialization has failed. Recommended Action No action is required. CCFG-1009 Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 228
on the specified slot to bring the blade online. CCFG-1013 Message . Message Type AUDIT Class CFG Severity INFO Probable Cause Indicates that the switch state has changed. Recommended Action No action is required. 206 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 229
deteriorated, and the Fibre Channel cable is not faulty. Replace the SFP transceivers or the cable if necessary. CDR-1002 Message switch. CDR-1003 Message S,C: HW ASIC Chip error type = 0x. If the problem persists, blade may need to be reset or replaced - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 230
, replace the blade. CDR-1005 Message S,P(): best effort QoS will be turned off at next port state change as it is not supported under this configuration. Message Type LOG Severity WARNING Probable Cause Indicates that quality of service (QoS - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 231
CDR-1007 5 CDR-1007 Message S,C: Internal link errors have been reported, no hardware faults identified, continuing to monitor for errors: flt1:0x, flt2:0x thresh1:0x. Message Type LOG Severity WARNING Probable Cause Indicates - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 232
blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. CDR-1011 Message S,P - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 233
Recommended Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. CDR-1015 Message Port re-initialized due to Link Reset failure on internal Port S,P - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 234
Recommended Action When this error is observed persistently, power cycle the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. CDR-1019 Message S,C: HW ASIC Chip TXQ FID parity error threshold reached type = 0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 235
the specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. CDR-1028 Message Detected excessive Link resets on the the small form-factor pluggable (SFP) transceiver or the cable on the peer port to which this port is connected. Fabric OS Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 236
bladed system, execute the slotPowerOff and slotPowerOn commands on the blade. To recover a non-bladed system, execute the fastBoot command on the switch. CHS-1003 Message Slot ENABLED but Not Ready during recovery, disabling slot = rval = . Message Type LOG Severity - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 237
number>. Message Type LOG Severity ERROR Probable Cause Indicates that the diagnostic blade attach operation has failed during failover or recovery. Recommended Action For a bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade. For a non-bladed - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 238
initialization of a module within the Cluster Node Manager (CNM) has failed. Recommended Action Download a new firmware version using the firmwareDownload command. CNM-1003 Message Crypto device cfg between local switch () and peer () out of sync. New encryption - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 239
Message Type LOG Severity INFO Probable Cause Indicates that the crypto service is enabled or disabled on the switch. Recommended Action No action is required. CNM-1005 Message Posting event CNM_EVT_GRP_LEADER_ELECTED Name [], WWN []. Message Type LOG Severity INFO Probable - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 240
5 CNM-1008 Recommended Action No action is required. CNM-1008 Message Posting event CNM_EVT_NODE_EJECT nodeName [], WWN []. Message Type LOG Severity INFO Probable Cause Indicates that the specified node is ejected from the Encryption Group (EG). Recommended Action No action - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 241
CNM-1011 5 CNM-1011 Message Posting event CNM_EVT_NODE_JOIN_TIMEOUT nodeName [], WWN [], ipaddress []. Message Type LOG Severity INFO Probable Cause Indicates the node join timeout. Recommended Action Take the peer node offline, and rejoin the node to Encryption Group - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 242
5 CNM-1015 Recommended Action No action is required. CNM-1015 Message Posting event Potential Cluster Split condition. Message Type LOG Severity INFO Probable Cause Indicates a Potential Cluster Split condition. Recommended Action No action is required. CNM-1016 Message Posting event - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 243
CNM-1018 5 CNM-1018 Message Got CNM_FSM_EVT_JOIN_REQ when already a member, My assigned name [], dropping request. Message Type LOG Severity INFO Probable Cause Indicates the node is already a member of the Encryption Group (EG). Recommended Action No action is required. CNM-1019 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 244
5 CNM-1021 CNM-1021 Message Failed to sign the node authentication message, admission control might fail. Message Type LOG Severity INFO Probable Cause Indicates that node admission control has failed. Recommended Action No action is required. CNM-1022 Message Operation not allowed on GL - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 245
hardware version> Node . Message Type LOG Severity INFO Probable Cause Indicates that a version mismatch has occurred. Recommended Action Upgrade the firmware or delete the node from the Encryption Group (EG). CNM-1027 Message Received HBT from non-Group Member Node []. Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 246
5 CNM-1028 CNM-1028 Message Certfile already exists. No need to sync up. Message Type LOG Severity INFO Probable Cause Indicates that the certificate file for the node already exists. Recommended Action No action is required. CNM-1029 Message Certfile - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 247
CNM-1032 5 Recommended Action No action is required. CNM-1032 Message Certfile size does not match cert file size sent by GL. Message Type LOG Severity WARNING Probable Cause Indicates that there is a size mismatch between a node's certificate - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 248
5 CNM-1035 CNM-1035 Message Cluster is in degraded state. Posting degrade event. Message Type LOG Severity WARNING Probable Cause Indicates an event is being posted to specify the cluster is in a degraded state. Recommended Action No action is required. CNM-1036 Message All the active nodes - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 249
-brain arbitration is won. Recommended Action No action is required. CNM-1041 Message Updating persistent Cluster DB, please avoid powering off the switch. Message Type LOG Severity INFO Probable Cause Indicates the system is updating the persistent database. Fabric OS Message Reference 227 53 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 250
5 CNM-1042 Recommended Action No action is required. CNM-1042 Message Completed updating persistent Cluster DB. Message Type LOG Severity INFO Probable Cause Indicates the persistent database update is complete. Recommended Action No action is required. CNM-1043 Message Received HBT from - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 251
CNM-1045 5 CNM-1045 Message Member node [] is having dual IP stack.Registering member node with dual IP in an EG with only IPv6 is not allowed. Message Type LOG Severity ERROR Probable Cause Indicates that the member node with dual IP stack was registered with the IPv6 Encryption Group ( - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 252
mode mismatch, ensure mode settings are same across all nodes in EG. Message Type LOG Severity ERROR Probable Cause Indicates mode mismatch between the switches, such as the Access Gateway mode mismatch. Recommended Action No action is required. 230 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 253
CNM-1052 5 CNM-1052 Message Member node registered with another Encryption Group. To proceed eject the member node [] from other EG. Message Type LOG Severity ERROR Probable Cause Indicates that the member node is registered with another Encryption Group (EG). Recommended Action - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 254
5 CNM-1055 CNM-1055 Message Got CNM_FSM_EVT_JOIN_REQ when already a member from same GL node, rejoining EG with GL []. Message Type LOG Severity INFO Probable Cause Indicates the node is rejoining the Encryption Group (EG). Recommended Action No action is required. CNM-1056 Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 255
Type LOG Severity INFO Probable Cause Indicates that the certificate pair is matched. Recommended Action No action is required. CNM-1061 Message IP of the switch changed from [] to []. Message Type LOG Severity INFO Probable Cause Indicates that the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 256
5 CNM-1062 Recommended Action No action is required. CNM-1062 Message Copied certificate to [] due to change in IP. Message Type LOG Severity INFO Probable Cause Indicates that the certificate was copied to the file with new IP name. Recommended Action No action is required. CNM- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 257
CNM-3003 5 CNM-3003 Message Event: cryptocfg Status: success, Info: Membernode \"\" added to encryption group. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that the specified member node was added to an encryption group. Recommended Action - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 258
5 CNM-3006 CNM-3006 Message Event: cryptocfg Status: success, Info: Heartbeat miss count set to . Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that the heartbeat miss value was set. Recommended Action No action is required. CNM-3007 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 259
CNM-3009 5 CNM-3009 Message Event: cryptocfg Status: success, Info: registered. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that the specified member node was registered. Recommended Action No action is required. CNM-3010 Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 260
5 CNM-3012 CNM-3012 Message Deleteing an EG with LUNs setup for encryption can lead to LUNs being disabled if Encryption Group name is not preserved (). Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that the Encryption Group (EG) was deleted. Recreate - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 261
and completed successfully. The Info about the parameters and AD variable is the description of the classes of configuration parameters that were downloaded. If Admin Domain (AD) is enabled, the AD number is specified in the description. Recommended Action No action is required. CONF-1001 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 262
Execute the errShow command to view the error log. Correct the error and execute the configUpload command again. CONF-1022 Message Downloading configuration without disabling the switch was unsuccessful. Message Type AUDIT Class CFG Severity WARNING Probable Cause Indicates an attempt to - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 263
CONF-1024 5 CONF-1024 Message configUpload failed . Message Type LOG Severity INFO Probable Cause Indicates a configUpload operation has failed. Recommended Action Execute the errShow command to view the error log. Correct the error and execute the configUpload command again. CONF- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 264
5 CONF-1032 CONF-1032 Message configRemove completed successfully . Message Type LOG Severity INFO Probable Cause Indicates that the configRemove command was initiated and completed successfully. Recommended Action No action is required. CONF-1040 Message configDefault Failed. < - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 265
CONF-1042 5 CONF-1042 Message Fabric Configuration Parameter changed to Message Type LOG | AUDIT Class CFG Severity INFO Probable Cause Indicates that the fabric configuration parameter value has been changed. Recommended Action No action is required. CONF-1043 Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 266
5 CTAP-1001 CTAP Messages CTAP-1001 Message Key acquisition for . Message Type LOG Severity INFO Probable Cause Indicates that a change in the tape pool database has triggered the key acquisition process for each pool. Recommended Action Do not start - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 267
physical WWN>, LUN ID: . Message Type LOG Severity INFO Probable Cause Indicates that the first-time encryption, key expired, or manual re-key operation is performed. The operation has been started, completed, failed, or cancelled. Recommended Action No action is required. CVLC-1002 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 268
5 CVLC-1004 CVLC-1004 Message Forceful encryption LUN removal while re-key session is still active. Container: , Initiator: , LUN ID: . Message Type LOG Severity INFO Probable Cause Indicates that the encryption LUN was forcefully removed - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 269
CVLC-1007 5 CVLC-1007 Message Removal of encryption LUN is not allowed when decrypt of existing data is enabled. Container: , Initiator: , LUN ID: . Message Type LOG Severity ERROR Probable Cause Indicates that there has been an attempt - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 270
>. Message Type LOG Severity ERROR Probable Cause Indicates that the tape container is configured with non-Brocade mode but there is no valid license. Recommended Action Obtain a license for non-Brocade mode. CVLC-1011 Message Third party license is required for encryption LUN in third party - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 271
CVLC-1013 5 CVLC-1013 Message Unable to retrieve key record from the key archive. Container: , Initiator: , LUN ID: . Message Type LOG Severity ERROR Probable Cause Indicates that the encryption engine is unable to retrieve the key - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 272
5 CVLC-1016 CVLC-1016 Message LUN is out of read only mode. Reason: . Container: , Initiator: , LUN ID: . Message Type LOG Severity INFO Probable Cause Indicates that the LUN is set to read/write - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 273
CVLC-1019 5 CVLC-1019 Message Metadata exists while data state is clear text. Container: , Initiator: , LUN ID: . Message Type LOG Severity ERROR Probable Cause Indicates that the data state in the LUN configuration is cleartext, but - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 274
5 CVLC-1022 CVLC-1022 Message User provided key ID is ignored while data state is clear text. Container: , Initiator: , LUN ID: . Message Type LOG Severity INFO Probable Cause Indicates that the key ID - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 275
CVLC-1025 5 CVLC-1025 Message Secondary Metadata exists for encrypted LUN not configured with -newLUN option. Container: , Initiator: , LUN ID: . Message Type LOG Severity ERROR Probable Cause Indicates that the secondary metadata exists - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 276
Initiator: , LUN ID: . Message Type LOG Severity WARNING Probable Cause Indicates that performing first-time encryption or manual re-key of primary LUN without splitting the mirror. Recommended Action Break the mirror and re-establish the mirror after re-key on - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 277
CVLC-1031 5 CVLC-1031 Message Primary LUN is restored from mirror LUN. LUN in read-only mode. Container: , Initiator: , LUN ID: . Message Type LOG Severity WARNING Probable Cause Indicates that a re-keyed primary LUN may have been - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 278
ID: because . Message Type LOG Severity INFO Probable Cause Indicates that the first-time encryption, key expired, or manual re-key operation failed. Recommended Action No action is required. CVLC-1035 Message A decommissioned LUN has been added back as encrypted LUN - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 279
CVLC-1041 5 CVLC-1041 Message . Container: , Initiator: , LUN ID: . Message Type LOG Severity WARNING Probable Cause Indicates that the host write operation on secondary metadata block region - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 280
Crypto Virtual LUN Manager (CVLM) daemon has failed. Recommended Action Download a new firmware version using the firmwareDownload command. CVLM-1003 Message Crypto device configuration has been committed by switch (). Message Type LOG Severity INFO Probable Cause Indicates that - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 281
group using the cryptocfg --commit command. CVLM-1005 Message Crypto service is on the switch. Message Type LOG Severity INFO Probable Cause Indicates that the crypto service is enabled or disabled on the switch. Recommended Action No action is required. CVLM-1006 Message Crypto - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 282
Type LOG Severity WARNING Probable Cause Indicates that the member of the HA cluster (HAC) is not in the fabric. Recommended Action Check the inter-switch link (ISL) port connected to the fabric. CVLM-1009 Message The member ( ) of HAC () is in the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 283
CVLM-1011 5 CVLM-1011 Message The HAC failover occurs at EE ( ). Message Type LOG Severity INFO Probable Cause Indicates that the HA cluster (HAC) failover occurs at the encryption engine. Recommended Action No action is required. CVLM-1012 Message The HAC - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 284
5 CVLM-1014 CVLM-1014 Message RD zone getting deleted for which there is no Host/Target (/) L2 zone exists in effective configuration. Message Type LOG Severity ERROR Probable Cause Indicates deletion of Frame Redirect (RD) zone and there is no corresponding Layer - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 285
CVLM-3001 5 CVLM-3001 Message Event: cryptocfg Status: success, Info: Failback mode set to . Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that the failback mode was set. Recommended Action No action is required. CVLM-3002 Message Event: - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 286
Recommended Action No action is required. CVLM-3006 Message Event: cryptocfg Status: success, Info: Current node WWN/slot / replaced with new node WWN/slot: / . Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that an - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 287
from EE / to EE /. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that a manual failback was performed to an encryption engine. Recommended Action No action is required. Fabric OS Message Reference 265 53 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 288
5 CVLM-3010 CVLM-3010 Message Event: cryptocfg Status: success, Info: Move crypto target container \"\" to EE /. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that the specified crypto-target container was moved to - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 289
CVLM-3013 5 CVLM-3013 Message Event: cryptocfg Status: success, Info: LUN , attached through Initiator \"\", added to crypto target container \"\". Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that a LUN was added - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 290
5 CVLM-3016 CVLM-3016 Message Event: cryptocfg Status: success, Info: LUN , attached through Initiator \"\" in crypto target container \"\", enabled. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that the specified - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 291
specified tape pool was modified. Recommended Action No action is required. CVLM-3020 Message Event: cryptocfg Status: success, Info: Manual rekey of LUN attached through Initiator \"\" in crypto tgt container \"\". Message Type AUDIT | LOG Class - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 292
5 CVLM-3022 CVLM-3022 Message Event: cryptocfg Status: success, Info: Resume rekey of LUN attached through Initiator \"\" in crypto tgt container \"\". Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that a resume re- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 293
CVLM-3025 5 CVLM-3025 Message Event: cryptocfg Status: started, Info: Decommission of device (container initiator , LUN ). Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that the decommission operation has started. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 294
5 CVLM-3028 CVLM-3028 Message Event: cryptocfg Status: success, Info: SRDF mode set to . Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that the Symmetrix Remote Data Facility (SRDF) mode was set. Recommended Action No action is required. 272 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 295
DOT1 Messages DOT1-1001 Message 802.1X is enabled globally. Message Type LOG Severity INFO Probable Cause Indicates that 802.1X is enabled globally. Recommended Action No action is required. DOT1-1002 Message 802.1X is disabled globally. Message Type LOG Severity INFO Probable Cause - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 296
that 802.1X authentication has failed on the specified port due to incorrect credentials or the remote authentication dial-in user service (RADIUS) server is not functioning properly. Recommended Action Check the credentials configured with the supplicant and the RADIUS server. 274 Fabric - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 297
for authentication. Message Type LOG Severity CRITICAL Probable Cause Indicates that there is no remote authentication dial-in user service (RADIUS) server available for authentication. Recommended Action Execute the aaaConfig --show command to verify that the configured RADIUS servers - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 298
5 DOT1-1010 DOT1-1010 Message Port is set in auto mode. Message Type LOG Severity INFO Probable Cause Indicates that the specified port is set to auto mode. Recommended Action No action is required. 276 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 299
Single bit errors are corrected, but other errors indicate either software errors or problems with the target system DRAM. Single bit errors can be expected to occur errors and all other error types should be reported to technical support for further action. ECC-1001 Message ECC Error - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 300
operational range of the switch. Refer to the Hardware Reference Manual for the environmental temperature range of your switch. Execute the fanShow ejector switch cycled to run POST and verify that the blade does not have any hardware problems. For the Brocade 300 and 6510, replace the switch. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 301
an optional number to identify the unit, slot, or port. The Brocade 300 switch has 4 fans and 1 power supply, but these parts cannot be replaced: the entire switch is a FRU. Recommended Action Reseat the FRU. If the problem persists, replace the FRU. EM-1005 Message has faulted. Sensor - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 302
firmware or replace the blade and make sure the replacement blade is compatible with your control processor (CP) type and firmware. If the incompatibility is with the logical switch Recommended Action Reseat the FRU. If the problem persists, replace the FRU. EM-1010 Message Received unexpected - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 303
in the message. There are serious internal Fabric OS configuration or hardware problems on the switch. Recommended Action Reseat the specified field-replaceable unit (FRU). If the problem persists, restart or power cycle the switch. Execute the diagPost command to make sure that Power-On Self-Test - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 304
specified field-replaceable unit (FRU). Recommended Action Reseat the FRU. If the problem persists, replace the FRU. switch. If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 305
(WWN) value before performing a system restart, power cycle, or firmware download operation. Recommended Action Change and commit the new WWN value. EM Indicates that the current chassis configuration option is not supported by the firmware on the standby control processor (CP). This is true - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 306
is faulted, it's an FCoE blade and the Ethernet switch service is not enabled. Please run - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 307
the field-replaceable unit (FRU) is intended for use. Refer to the appropriate Hardware Reference Manual for instructions on inserting the switch blades. EM the cause of the error state. Reseat the field-replaceable unit (FRU). If the problem persists, replace the FRU. EM-1034 Message set - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 308
that circuit. The Switch side value designates the circuit switch facing the cable side of the replaceable unit (FRU) is not present on the switch. If the FRU is a World Wide Name (WWN) card, the default WWN and IP addresses are used for the switch. Recommended Action Reseat the FRU. If the problem - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 309
read incorrectly, or corrupted in the object database, which contains information about all FRUs. Recommended Action Reseat the FRU. If the problem persists, replace the FRU. EM-1043 Message Can't power . Message Type LOG Severity WARNING Probable Cause Indicates - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 310
replaceable unit (FRU) cannot be powered on because the associated logical switch is shutdown. Recommended Action Execute the switchStart command on the associated logical switch there was not enough power available. Recommended Action The Brocade 24000 requires only a single power supply for a - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 311
supported on that chassis (backplane revision D2). Remove the blade from the chassis. If the error is due to the switch configuration, the logical switch configuration -Integrated Circuit (I2C) bus problems have been resolved and I2C access to the field-replaceable unit (FRU) has become available - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 312
) parity error. Recommended Action No action is required if the switch does not reach the reset threshold for the switch or blade. If the reset threshold is reached on the switch or blade, the switch or blade will be faulted and should be replaced. 290 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 313
usable. The blade may only be supported by a later (or earlier) version of the firmware. Recommended Action Change the control processor (CP) firmware or replace the blade. Make sure the replacement is compatible with your switch type and firmware. EM-1060 Message Stopping synchronization of - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 314
CP, then reboot or run haSyncStart. Message Type LOG Severity WARNING Probable Cause Indicates that the blade in the system is not supported by the firmware on the standby control processor (CP). Recommended Action Remove all blades of the specified type or upgrade the standby CP. After an - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 315
problem blade when such a condition occurred. Recommended Action Contact your switch service provider for assistance. EM-1065 Message SAS Virtualization Services the previously incompatible Fabric OS or Storage Application Services (SAS) firmware has been upgraded and is now compatible. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 316
firmware version. Recommended Action Upgrade the software on the standby CP or disable the software feature on this CP. To disable the Ethernet switch service configuration or hardware problems on the switch. Recommended Action Restart or power cycle the switch. If the problem persists, execute - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 317
. There must be at least one core blade in enabled state for the chassis to be considered ready. Recommended Action Insert and close the ejector switch on missing core blades. Reseat or replace core blades that are faulted or powered off. Fabric OS Message Reference 295 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 318
by using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware problems. • On bladed systems, replace the specified FRU; otherwise, replace the switch. 296 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 319
Action Discontinue the firmware download, identify the down-level switch or switches that do not support the Coordinated HotCode protocol, and upgrade the down-level switches. Then, restart the firmware download on this switch. Note that upgrading a down-level Brocade switch in a mixed interop - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 320
Probable Cause Indicates that during the Coordinated HotCode protocol, a switch in the fabric did not accept the resume message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to this issue. Recommended Action No - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 321
specified fabric name is not unique for this fabric. Recommended Action Select an appropriate fabric name and set it again from any switch. ESS-1010 Message Duplicate Fabric Name - matching with FID . Message Type AUDIT | LOG Class FABRIC Severity WARNING Probable - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 322
persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. ESW-1002 Message Security violation: Unauthorized device tries to FLOGI to port . Message Type - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 323
standby control processor (CP) does not support N_Port ID Virtualization (NPIV) functionality, but the switch has some NPIV devices logged in to the fabric. Recommended Action Load a firmware version on the standby CP that supports NPIV functionality using the firmwareDownload command. Fabric OS - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 324
reason>\". Message Type LOG Severity WARNING Probable Cause Indicates that the switch port is disabled due to the reason displayed in the message. Replace the blade with ports that support port swap. Then swap ports back to the port's default area. Refer to the Fabric OS Administrator's Guide - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 325
Message Type LOG Severity WARNING Probable Cause Indicates that the event could not be sent to remote proxy. This could happen if the remote proxy switch cannot be reached through in-band. Recommended Action Make sure that the specified remote domain is present in the fabric. Fabric OS Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 326
size>, wanted . Message Type LOG Severity WARNING Probable Cause Indicates that an internal link service (ILS) information unit of invalid size has been received. The neighbor switch has sent a payload with an invalid size. 304 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 327
switch for problems. Run the errShow command on the neighbor switch to view the error log for additional messages. Check for a faulty cable or deteriorated small form-factor pluggable (SFP). Replace the cable the supportSave command and contact your switch service provider. FABR-1004 Message port: - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 328
has already been deallocated. This message is rare and usually indicates a problem with the Fabric OS. Recommended Action In case of severe memory FTP transfers; then run the supportSave command and contact your switch service provider. FABR-1007 Message IU free error, caller: - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 329
message is rare and usually indicates a problem with the Fabric OS. Recommended Action If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Fabric OS Message Reference 307 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 330
indicates a problem with the Fabric OS. Recommended Action The system will recover by failing over to the standby CP. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. FABR - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 331
Cause Indicates that the application exceeded request domain ID (RDI) requests for the insistent domain ID. All E_Ports are disabled; isolating the specified switch from the fabric. Recommended Action Verify that the insistent domain ID is unique in the fabric and then re-enable the E_Ports. Run - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 332
command. FABR-1019 Message Critical fabric size () exceeds supported configuration (). Message Type FFDC | LOG Severity CRITICAL Probable Cause Indicates that this switch is a value-line switch and has exceeded the limited fabric size: that is, a specified - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 333
the size of the fabric must be changed to within the licensed limit. Contact your switch provider to obtain a full fabric license. FABR-1023 Message Fabric size is within supported configuration (). Fabric limit timer () stopped at . Message Type - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 334
period>. Message Type LOG Severity INFO Probable Cause Indicates that the fabric size has exceeded the limit set by your value-line switches. Value-line switches have a limited fabric size (for example, a specified limit on the number of domains). This value is defined by your specific value - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 335
retries sending internal link service (ILS) to the . FABR-1032 Message Remote switch with domain ID - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 336
Indicates the Slave port's Trunk Area differs from that of the Master port. Recommended Action Move the cable to a port to match with the same Master Trunk Area, or disable Trunk Area. You must manually enable the port or the port remains disabled forever. Refer to the Fabric OS Administrator - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 337
domain id>). Message Type LOG Severity WARNING Probable Cause Indicates an invalid domain ID zero has been received. Recommended Action Check the principal switch for the invalid domain ID zero. FABR-1040 Message Speed is not 2G, 4G, or 8G with F_Port trunking enabled. Persistently disabling - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 338
your switch service provider. FABR-1043 Message Detected Fabric ID conflict with remote (not neighbor) switch switch is not an adjacent to the local switch. Recommended Action Make sure that all the switches in the fabric have the same FID or upgrade the switch firmware to a VF-capable firmware - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 339
switch are disabled. Recommended Action Make sure that all the switches in the fabric have the same Base Switch attribute or upgrade the switch firmware to a VF-capable firmware Move some ports out of the default switch to make areas available. Fabric OS Message Reference 317 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 340
a Fabric ID (FID) conflict with the inherited FID of the local switch. Recommended Action Make sure that all the switches in the fabric have the same FID or upgrade the switch firmware to a VF-capable firmware. FABR-1049 Message Detected Fabric ID (FID inherited) conflict with - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 341
(ASIC) issue detected by link traffic test failure. Recommended Action Replace the faulty SFPs, cables, or blade. FABR-1052 Message The configured port speed (16G command to change the port speed. FABR-1053 Message The switch is disabled due to an inconsistency found in the interop config - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 342
5 FABR-1054 FABR-1054 Message Rebooting the standby as it received an update before port [] is expanded. Message Type LOG | FFDC Severity INFO Probable Cause Indicates that the standby control processor (CP) did not have the port because the port expand operation is still in - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 343
or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. FABS-1004 Message process () - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 344
power cycle the active CP (for modular systems) or the switch (for single-board systems). If the message persists, run the firmwareDownload command to update the firmware. FABS-1006 Message : object unit . Message Type LOG Severity - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 345
an object status field. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. FABS-1008 Message : Media oid mapping failed. Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 346
problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware an incorrect field-replaceable unit (FRU) header, inability to read the FRU header, or the blade may not be supported by this platform - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 347
of field-replaceable unit (FRU supported by this platform or Fabric OS version. Recommended Action Verify that the FRU is valid for use in this system and this version of Fabric OS. Reseat the FRU. If this is a valid FRU and reseating does not solve the problem, replace OS problem. Recommended - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 348
The problem can be corrected by changing the firmware version on either the CP or on the AP blade. You can modify the firmware version on the CP blade by using the firmwareDownload command. Refer to the release notes to determine whether a non-disruptive firmware download is supported between - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 349
is low on memory and failed to allocate new memory for an information unit (IU). Recommended Action A non-bladed switch will automatically reboot. For a bladed switch, the active CP blade will automatically fail over and the standby CP will become the active CP. Fabric OS Message Reference 327 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 350
for . Message Type LOG Severity ERROR Probable Cause Indicates a memory failure. Recommended Action Check the memory usage on the switch using the memShow command. FCOE-1002 Message Max logingroup limit reached at . Message Type LOG Severity WARNING Probable Cause Indicates - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 351
from the login group has failed. Recommended Action Execute the supportSave command and restart the system. If the problem persists, contact your switch service provider. FCOE-1005 Message : membership check failed in logingroup: . Message Type LOG Severity ERROR Probable Cause - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 352
or initialization of the FCoE trace has failed. Recommended Action Execute the supportSave command and restart the system. If the problem persists, contact your switch service provider. FCOE-1012 Message Request to delete port from VLAN failed. Message Type LOG Severity ERROR Probable - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 353
add ports to the specified VLAN has failed. Recommended Action Execute the supportSave command and restart the system. If the problem persists, contact your switch service provider. FCOE-1015 Message Request to add MACs to Layer 2 for ifindex 0x failed, rc:. Message Type - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 354
. Recommended Action No action is required. FCOE-1022 Message Max FCoE device login limit reached. Message Type LOG Severity WARNING Probable Cause Indicates that the switch has reached its maximum allowed FCoE device limit. Recommended Action Do not add any more FCoE devices to the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 355
login (FLOGI) before it can send an FDISC. Recommended Action It is due to a CNA or target driver issue. Contact CNA or target driver support team for assistance. FCOE-1025 Message FCoE logout received on FIP VN port. Message Type LOG Severity WARNING Probable Cause Indicates pre-FIP logout - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 356
a CNA or target driver issue. Contact CNA or target driver support team for assistance. FCOE-1027 Message : : - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 357
is due to a CNA or target driver issue. Contact CNA or target driver support team for assistance. FCOE-1030 Message Version mismatch between FIP LOGO and root VN port that high availability (HA) failover or switch reboot may be in progress. Fabric OS Message Reference 335 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 358
the PFC for the specified FCoE priority or change the FCoE priority using the fabric-map default command under the FCoE configuration mode. FCOE-1037 Message Logingroup dropped for switch WWN: , due to name conflict while merging. Message Type LOG Severity WARNING Probable Cause - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 359
Logingroup deleted. Message Type LOG Severity INFO Probable Cause Indicates that the specified login group is deleted from the switch login group table. Recommended Action No action is required. FCOE-1040 Message Logingroup name changed from to - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 360
5 FCOE-1042 Recommended Action No action is required. FCOE-1042 Message FCoE login configuration transaction saved fabric-wide. Message Type LOG Severity INFO Probable Cause Indicates that the FCoE login configuration transaction is saved fabric-wide. Recommended Action No action is - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 361
FCOE-1045 5 FCOE-1045 Message FCoE port is configured as VE port. Message Type LOG Severity INFO Probable Cause Indicates that the specified FCoE port is configured as a virtual expansion (VE) port. Recommended Action No action is required. FCOE-1046 Message fcoed.conf file - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 362
5 FCOE-1048 Recommended Action No action is required. 340 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 363
device firmware. FCPD-1003 Message Probing failed on which is possibly a private device which is not supported in this port type. Message Type LOG Severity INFO Probable Cause Indicates that device probing has failed because private devices will not respond to the switch port - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 364
5 FCPD-1003 Recommended Action The Brocade 4100, 4900, 5000, 7500, and AP 7600 do not support private loop devices. Refer to the switch vendor for a list of other port types that support private devices for inclusion into the fabric. 342 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 365
to ON. Message Type LOG Severity WARNING Probable Cause Indicates a device that does not support authentication has tried to log in to the switch when the device authentication policy is in ON status on the switch. Recommended Action Enable the authentication on the device or set the device - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 366
PID> as part of duplicate Port WWN detection policy. Message Type LOG Severity WARNING Probable Cause Indicates that the specified N_Port ID virtualization (NPIV) port has the same Port World Wide Name (PWWN) as the old port. Recommended Action No action is required. FCPH-1005 Message FDISC - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 367
FCR-1001 5 FCR Messages FCR-1001 Message FC router proxy device in edge created at port . Message Type LOG Severity INFO Probable Cause Indicates that a proxy device at a port in the edge fabric has been imported at the specified port. Recommended Action No action is required. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 368
the devices are functioning properly. Verify that all small form-factor pluggables (SFPs) are seated correctly. Check for faulty cables, deteriorated SFPs, or dirty connections. Replace the cables and the SFPs if necessary. FCR-1005 Message FC router LSAN zone device removed at port - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 369
FCR-1007 5 FCR-1007 Message FC router LSAN zone deleted at port . Message Type LOG Severity INFO Probable Cause Indicates that a logical storage area network (LSAN) zone attached to the specified port was deleted in the edge fabric. Recommended Action No action is required. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 370
5 FCR-1010 FCR-1010 Message FC router LSAN zone disabled at port . Message Type LOG Severity INFO Probable Cause Indicates that a logical storage area network (LSAN) zone is disabled in the edge fabric attached to the specified port. Recommended Action No action is required. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 371
>. Message Type LOG Severity INFO Probable Cause Indicates that a fabric is no longer accessible through the backbone fabric. This may be caused by a link or switch failure. Recommended Action No action is required. Fabric OS Message Reference 349 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 372
many proxy devices are created in the fabric with the port resource problem. LSAN zones are removed using standard zoning commands such as zoneShow, the port that a device is attached to, and then disconnecting the cable or disabling the device. FCR-1019 Message EX_Port or VEX_Port entries - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 373
FCR-1021 5 3. Use zoning commands on the edge fabrics, to reduce the LSAN zone entries on the edge fabrics. 4. Use the portEnable command on each EX_Port, one at a time, and verify that this error is not reported again. FCR-1021 Message Local LSAN device entries exhausted. Message Type LOG - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 374
be in use are reused as needed. Recommended Action It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch is deployed in a very large MetaSAN environment with a large number of logical storage area network (LSAN) devices and fabrics, or there are highly dynamic - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 375
be in use are reused as needed. Recommended Action It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch is deployed in a very large MetaSAN environment with a large number of logical storage area network (LSAN) devices and fabrics, or there are highly dynamic - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 376
5 FCR-1030 FCR-1030 Message Physical device came online at fabric . Message Type LOG Severity INFO Probable Cause Indicates that the physical device World Wide Name (WWN) came online in the specified fabric. Recommended Action No action is required. FCR-1031 Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 377
FCR-1034 5 Recommended Action No action is required. FCR-1034 Message LSAN zone added in backbone fabric. Message Type LOG Severity INFO Probable Cause Indicates that a new logical storage area network (LSAN) zone was added to the backbone fabric. Recommended Action No action is required. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 378
Severity WARNING Probable Cause Indicates that the number of cfg, zone, or alias entries created in a local fabric is greater than the local switch's zone database limitations. Recommended Action Remove excess cfg, zone, or alias entries so that the number of logical storage area network (LSAN - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 379
FCR-1040 5 FCR-1040 Message Proxy device deleted in the backbone fabric. Message Type LOG Severity INFO Probable Cause Indicates that a proxy device created in the backbone fabric was deleted. Recommended Action No action is required. FCR-1041 Message LSAN zone device removed in the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 380
Indicates an incoming exchange link parameter (ELP) command that is not supported. Recommended Action Use the portEnable and portDisable to enable or disable the port. If the problem persists, contact your switch service provider. FCR-1053 Message Port was disabled, - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 381
(SFP). Replace the cable or the SFP if necessary. Run the portLogDumpPort command on both the receiving and transmitting ports. Run the fabStatsShow command on the transmitting switch. If the message persists, collect switch information using the supportSave command, and contact your switch service - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 382
Action Check the port configuration on both sides of the link using the portCfgShow command. Investigate the other switch for more details. Run the errShow command on the other switch to view the error log for additional messages. FCR-1058 Message Port isolated due to mismatched - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 383
virtual channel (VC) Link Init is enabled on the local switch and the remote switch is negotiating in R_RDY mode. The fabric might not form is required. FCR-1062 Message Port disabled, system only supports EX/VEX_ports. Message Type LOG Severity INFO Probable Cause - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 384
with local fabric ID . Message Type LOG Severity INFO Probable Cause Indicates that the fabric ID of the switch does not match the local switch. Recommended Action Run the switchShow command to display the fabric ID. Change the fabric ID to match on both ends by modifying - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 385
Action If the fabric split, merge the fabrics and manually re-enable the port. If there is another fabric with in connected fabric exceeds the maximum number supported by the Fibre Channel. The limit 2 (disabled). Note that the FC Routing service is disabled by the factory. Recommended Action No - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 386
command with the fcrState set to 1 (enabled). Note that the FC Routing service is disabled by the factory. Recommended Action No action is required. FCR-1070 Message The FC Routing configuration is set to default. Message Type LOG Severity INFO Probable Cause Indicates that the FC Routing - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 387
Zones supported. Message Type LOG Severity INFO Probable Cause Indicates that an older version switch in the backbone or edge that supports a Indicates that the remote control processor (CP) has older firmware, which supports a lower number of logical storage area network (LSAN) zones - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 388
the port. Recommended Action Make sure to remain within the maximum number of supported front domains. FCR-1077 Message Port rejected fabric binding request/check from the M-Model switch; . Message Type LOG Severity WARNING Probable Cause Indicates that an M-Model - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 389
Probable Cause Indicates that during the Coordinated HotCode protocol, a switch in the fabric has not responded to the pause message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been the result of the rejected pause message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 390
Probable Cause Indicates that during the Coordinated HotCode protocol, a switch in the fabric did not accept the pause message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been the result of this issue. Recommended Action - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 391
protocol from completing. Any data traffic disruption observed during the firmware download may have been the result of this issue. Recommended Action No action is required. FCR-1085 Message HA sync lost as remote CP does not support FCR based matrix. Message Type LOG Severity ERROR Probable - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 392
5 FCR-1087 FCR-1087 Message ExPort connects to fabric with capability to use XISL domain . Message Type LOG Severity ERROR Probable Cause Indicates that the EX_Port connects to the logical fabric containing a domain that has the capability to use extended ISL ( - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 393
Probable Cause Indicates that the FCR ELS trap entries are exhausted. Recommended Action Execute the supportSave command and contact your switch service provider. FCR-1093 Message Slave EX-Port interopmode conflicts with trunk master . Disabling the port. Message Type LOG - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 394
Brocade Native mode fabrics. FCR-1095 Message The EX-Port is configured in 'McData/Open' Mode which is no longer supported phase failed. Recommended Action Usually this problem is transient. The authentication may your switch service provider. 372 Fabric OS Message Reference 53-1002749 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 395
that failed to get memory. Recommended Action Usually this problem is transient. The authentication may fail. Reinitialize authentication automatic FTP transfers; then run the supportSave command and contact your switch service provider. FCR-1098 Message Invalid message code for - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 396
Disabled> RdBlkId . Message Type LOG Severity INFO Probable Cause Indicates the configuration was changed manually. Recommended Action No action is required. 374 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 397
in an error case. Recommended Action If there was a job failure associated with this event, contact your vendor's customer support. FICN-1008 Message DevDiskEgr:FICON Purge Path received Path=0x. Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 398
to read the sense data. Recommended Action If there was a job failure associated with this event, contact your vendor's customer support for assistance. FICN-1010 Message DevDiskEgr:Device level exception flag found for Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 399
attached storage device (DASD) Control Unit. Recommended Action If there was a job or I/O failure associated with this event, contact your vendor's customer support for assistance. FICN-1013 Message DevDiskIng:Status=0x received in - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 400
(LRC) values. This indicates data corruption between the emulation processing components. Recommended Action Contact your vendor's customer support for assistance. FICN-1016 Message DevIng:Received Logical Path Removed response:Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 401
Control Unit sent a frame that cannot be associated with a FICON Control Unit number (CUADDR). Recommended Action Contact your vendor's customer support for assistance. FICN-1019 Message DevTapeEgr:AS Link Level Reject (LRJ) from Chan on Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 402
in emulation. Recommended Action If there was an unexpected job failure associated with this event, contact your vendor's customer support for assistance. FICN-1022 Message DevTapeEgr:FICON Selective Reset:Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 403
. Recommended Action If there was an unexpected job failure or I/O error associated with this event, contact your vendor's customer support for assistance. FICN-1025 Message DevTapeIng:Auto Sense Data received on Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 404
Recommended Action If there was an unexpected job failure or I/O error associated with this event, contact your vendor's customer support for assistance. FICN-1028 Message HostDiskIng:FICON Cancel received Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 405
. Recommended Action If there was an unexpected job failure or I/O error associated with this event, contact your vendor's customer support for assistance. FICN-1031 Message HostDiskIng:FICON System Reset received on Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 406
the channel side noted corruption from the Control Unit- or device-side processing. Recommended Action Contact your vendor's customer support for assistance. FICN-1035 Message HostIng:FICON System Reset received on Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 407
Severity ERROR Probable Cause Indicates a locally connected FICON channel sent a frame that could not be associated with a FICON device. Recommended Action Contact your vendor's customer support for assistance. Fabric OS Message Reference 385 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 408
from the channel. Recommended Action If there was an unexpected job failure or I/O error associated with this event, contact your vendor's customer support for assistance. FICN-1041 Message HostTapeEgr:AS Link Level Reject (LRJ) from CU Rx Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 409
or network errors can cause a Selective Reset. Recommended Action If this was an unexpected event, contact your vendor's customer support for assistance. FICN-1044 Message HostTapeIng:FICON Selective Reset:Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 410
This is performed during the path recovery. Recommended Action If this was an unexpected event, contact your vendor's customer support for assistance. FICN-1046 Message HostTapeIng:LRJ received on Path=0x lastCmds - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 411
Indicates the operator has canceled a read or write job. Recommended Action This is an unexpected event; contact your vendor's customer support for assistance. FICN-1049 Message ProcessIngTirData:Lost Logical Path for Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 412
extended direct attached storage device (DASD) device. Recommended Action If this was an unexpected event, contact your vendor's customer support for assistance. FICN-1053 Message XRC Withdraw From Session: SessID=, Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 413
devices from the eXtended Remote Copy (XRC) session. Recommended Action If this was an unexpected event, contact your vendor's customer support for assistance. FICN-1056 Message FICON Emulation Error Error Code=, Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 414
frame could not be created and sent to a device. Recommended Action This is an unexpected event; contact your vendor's customer support for assistance. FICN-1058 Message Error return from frame generation processing for a FICON control unit: Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 415
in the removal of an existing fast path hash table entry. Recommended Action This is an unexpected event; contact your vendor's customer support for assistance. FICN-1062 Message Ingress Abort:Oxid=0x:Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 416
been received from a peer FC interface for an active emulation exchange. Recommended Action This is an unexpected event; contact your vendor's customer support for assistance. FICN-1064 Message Ingress Abort:Oxid=0x:Unknown Path on GEPort= VEPort - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 417
for an emulation CH exchange. Recommended Action If there were associated I/O errors at the same time as this event, contact your vendor's customer support for assistance. FICN-1068 Message Ingress Abort:Oxid=0x:Abort for CU=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 418
pipelining and not the unit check. If there are associated I/O error messages with this event, contact your vendor's customer support for assistance. FICN-1071 Message HostTapeIngr:Tape Loaded on Path=0x. Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 419
FICN-1072 5 FICN-1072 Message DevTapeEgr:Tape Loaded on Path=0x. Message Type LOG Severity INFO Probable Cause Indicates the tape I/Os are processed from a locally connected Logical Partition (LPAR), which - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 420
5 FICN-1075 Recommended Action No action is required. FICN-1075 Message HostTapeIngr:ReadBlkReport:Path=0x:Emuls=0x:Cmds=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 421
FICN-1077 5 FICN-1077 Message DevTapeEgr:Unloaded:Path=0x:states=0x:cmds=0x: - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 422
5 FICN-1079 FICN-1079 Message DevTapeEgr:ReadBlkReport:Path=0x:Emuls=0x:Cmds=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 423
Cause Indicates an attached port with the established FICON emulated path has logged out from the switch. Recommended Action This may be an unexpected event; contact your vendor's customer support for assistance. FICN-1084 Message fcFicInit: No DRAM2 memory available, FICON emulation is disabled - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 424
Message Type LOG Severity ERROR Probable Cause Indicates a FICON FCIP tunnel to the peer switch has been terminated. Recommended Action This is an unexpected event; contact your vendor's customer support for assistance. FICN-1087 Message DevTeraEgr:AS Link Level Reject (LRJ) from Chan on - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 425
in emulation. Recommended Action If there was an unexpected job failure associated with this event, contact your vendor's customer support for assistance. FICN-1090 Message DevTeraEgr:FICON Selective Reset:Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 426
for a device. Recommended Action If there was an unexpected job failure associated with this event, contact your vendor's customer support for assistance. FICN-1092 Message DevTeraEgr:FICON Purge received Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 427
. Recommended Action If there was an unexpected job failure or I/O error associated with this event, contact your vendor's customer support for assistance. FICN-1095 Message DevTeraIng:Device level exception found for Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 428
logical path to the Logical Partition (LPAR). Recommended Action If this was an unexpected event; contact your vendor's customer support for assistance. FICN-1098 Message HostTeraIng:FICON Cancel received Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 429
This is performed during the path recovery. Recommended Action If this was an unexpected event, contact your vendor's customer support for assistance. FICN-1102 Message HostTeraIng:LRJ received on Path=0x lastCmds - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 430
pipelining and not the unit check. If there are associated I/O error messages with this event, contact your vendor's customer support for assistance. FICN-1104 Message DevTeraEgr:Device Ready on Path=0x. Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 431
sequence from the device. Recommended Action If there was a job failure associated with this event, contact your vendor's customer support for assistance. FICN-1107 Message DevPrintEgr:FICON Cancel received Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 432
in emulation. Recommended Action If there was an unexpected job failure associated with this event, contact your vendor's customer support for assistance. FICN-1110 Message DevPrintEgr:FICON Selective Reset:Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 433
not have a path established to the Control Unit. Recommended Action This is normally an unexpected event; contact your vendor's customer support for assistance. FICN-1114 Message DevPrintIng:Device level exception found for Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 434
from the device. Recommended Action If there was an unexpected job failure or I/O error associated with this event, contact your vendor's customer support for assistance. FICN-1116 Message HostPrintEgr:AS Link Level Reject (LRJ) from CU Rx Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 435
timeout condition and issued a Selective Reset. Recommended Action If this was an unexpected event, contact your vendor's customer support for assistance. FICN-1120 Message HostPrintIng:FICON Purge received:Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 436
or I/O error associated with this event, contact your vendor's customer support for assistance. FICN-2005 Message FICON VEPort Feature Severity INFO Probable Cause Indicates the configuration was changed manually. Recommended Action No action is required. 414 Fabric OS - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 437
FC interface for an exchange. Recommended Action If there were associated I/O errors at the same time as this event, contact your vendor's customer support for assistance. FICN-2065 Message Egress Abort:Oxid=0x:Unknown Path on VEPort= from SID=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 438
Indicates an attached port which had a FICON emulated path established has logged out from the switch. Recommended Action This may be an unexpected event; contact your vendor's customer support for assistance. FICN-2083 Message EmulEls:SW_RSCN received on VEPort= Domain=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 439
a FICON or Fibre Channel Protocol (FCP) emulation-enabled FCIP tunnel to the peer switch has been terminated. Recommended Action This is an unexpected event; contact your vendor's customer support for assistance. FICN-2087 Message FICON connected 3900 printer discovered Path=0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 440
variable is an internal error number. Recommended Action If this is a bladed switch, execute the haFailover command. If the problem persists, or if this is a non-bladed switch, download a new firmware version using the firmwareDownload command. FICU-1003 Message : FICON - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 441
FMS Mode using the ficonCupSet command. Refer to the Fabric OS Administrator's Guide for information on core PID mode. FICU-1005 Message Failed to initialize port (FICON-CUP) daemon failed. Recommended Action Download a new firmware version using the firmwareDownload command. FICU-1006 Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 442
are low. This may be a transient problem. Recommended Action Check the memory usage on the switch using the memShow command. If the message automatic FTP transfers; then execute the supportSave command and contact your switch service provider. FICU-1008 Message FMS mode has been enabled. Port - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 443
FICU-1010 5 FICU-1010 Message FMS mode enable failed due to port(s) with areas 0xFE or 0xFF is(are) connected to device(s). Message Type LOG Severity WARNING Probable Cause Indicates that the FICON Management Server (FMS) mode was not enabled because ports with areas 0xFE or 0xFF are - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 444
FICON port address and port number relationship. For more information, refer to the "FICON and FICON CUP in Virtual Fabrics" section of the FICON Administrator's Guide. 422 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 445
LP(). Message Type AUDIT | LOG Class CFG Severity INFO Probable Cause Indicates that the FICON Management Server (FMS) has disabled the switch. Recommended Action No action is required. FICU-1020 Message Port Addrs () have been Blocked by . Message Type AUDIT | LOG - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 446
5 FICU-1022 FICU-1022 Message Detected FC8-48 and/or FC8-64 that are not manageable when FMS mode port blade ports in the switch. Recommended Action No action is required. For more information on the FICON CUP restrictions, refer to the FICON Administrator's Guide. FICU-1024 Message Detected - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 447
FKLB-1001 5 FKLB Messages FKLB-1001 Message exchange overlapped, pid=. Message Type LOG Severity WARNING Probable Cause Indicates that the FC kernel driver has timed out the exchange while the application is still active. When the FC kernel driver reuses the exchange, the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 448
Probable Cause Indicates that the link state update (LSU) size exceeds the value the system can support. Recommended Action Reduce the number of switches in the fabric or reduce the number of redundant inter-switch links (ISLs) between two switches. 426 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 449
FLOD-1005 5 FLOD-1005 Message Invalid received domain ID: . Message Type LOG Severity WARNING Probable Cause Indicates that the received link state record (LSR) contained an invalid domain number. Recommended Action No action is required; the LSR is discarded. FLOD-1006 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 450
of range because it does not exist on the switch. Recommended Action No action is required. This is a temporary kernel error that does not affect your system. If the problem persists, execute the supportSave command and contact your service provider. FSPF-1002 Message Wrong neighbor ID ( - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 451
from another manufacturer with a section ID other than 0 is incompatible in a fabric of Brocade switches. Disconnect the incompatible switch. FSPF-1006 Message FSPF Version not supported, input port = . Message Type LOG Severity ERROR Probable Cause Indicates that - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 452
Type LOG Severity INFO Probable Cause Indicates that the current inter-chassis link (ICL) topology is valid for routing from the local switch. Recommended Action No action is required. FSPF-1011 Message 16G ICL topology is unbalanced. Message Type LOG Severity WARNING Probable Cause Indicates - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 453
FSPF-1012 5 Recommended Action Investigate current ICL configuration to ensure that all recommendations for cabling are satisfied. FSPF-1012 Message All existing ICL topology imbalances have been corrected. Message Type LOG Severity INFO Probable Cause Indicates that the existing inter- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 454
command. For non-bladed systems, restart the switch using the reboot command. If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. 432 Fabric OS Message Reference 53 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 455
synchronization (FSS) device has failed. Recommended Action If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. FSS-1006 Message No FSS message available. Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 456
the network configuration and then execute the haSyncStart command to restore the high availability (HA) synchronization. If the problem persists, contact your switch service provider. FSS-1008 Message FSS Error: . Message Type LOG Severity CRITICAL Probable Cause Indicates that - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 457
Indicates that a Fabric OS state synchronization (FSS) error may have occurred. Recommended Action Execute the supportSave command and contact your switch service provider. FSS-1011 Message FSS Info: . Message Type LOG Severity INFO Probable Cause Indicates a Fabric OS state - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 458
synchronize, execute the haDump command to diagnose the problem. If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. FSSM-1004 Message Incompatible software version in - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 459
FSSM-1004 5 Recommended Action For a dual CP system, execute the firmwareDownload command to load compatible firmware on the standby CP. Fabric OS Message Reference 437 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 460
are functioning normally. Verify that the location temperature is within the operational range of the switch. Refer to the hardware reference manual for the environmental temperature range of your switch. FW-1003 Message , is above high boundary(High=, Low=). Current - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 461
Cause Indicates that the internal temperature of the switch has changed from a value outside of the acceptable problems typically contribute to temperature problems. Recommended Action Consistently abnormal fan speeds generally indicate that the fan is failing. Replace the fan field-replaceable - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 462
of the fan has risen above the high boundary. Fan problems typically contribute to temperature problems. Recommended Action Consistently abnormal fan speeds generally indicate that the fan is failing. Replace the fan field-replaceable unit (FRU). FW-1008 Message , is between high and - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 463
. Recommended Action Verify that you have installed the power supply correctly and that it is correctly seated in the chassis. If the problem persists, replace the faulty power supply. FW-1011 Message , is above high boundary(High=, Low=). Current value is - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 464
that the temperature of the small form-factor pluggable (SFP) has risen above the high boundary. Frequent fluctuations in temperature may indicate a deteriorating SFP. Recommended Replace the SFP. Action 442 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 465
working condition. If the counter often exceeds the threshold, the SFP is deteriorating. Recommended Action Verify that your optical components are clean and function properly. Replace deteriorating cables or SFPs. Check for damage from heat or age. Fabric OS Message Reference 443 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 466
you determine whether the SFP is in good working condition. If the counter often exceeds the threshold, the SFP is deteriorating. Recommended Action Replace the SFP before it deteriorates. FW-1040 Message , is between high and low boundaries(High=, Low=). Current - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 467
counter often exceeds the threshold, the SFP is deteriorating. Recommended Action Verify that your optical components are clean and function properly. Replace deteriorating cables or SFPs. Check for damage from heat or age. FW-1043 Message , is above high boundary(High=, Low - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 468
pluggable (SFP) voltage has fallen below the low boundary. Recommended Action Verify that your optical components are clean and function properly. Replace deteriorating cables or SFPs. Check for damage from heat or age. FW-1047 Message , is above high boundary(High=, Low - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 469
the value of the small form-factor pluggable (SFP) voltage has changed. Frequent voltage fluctuations indicate that the SFP is deteriorating. Recommended Replace the SFP. Action FW-1050 Message , is below low boundary(High=, Low=). Current value is - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 470
above the high boundary. High voltages indicate possible hardware failures. Recommended Action Frequent voltage fluctuations indicate that the SFP is deteriorating. Replace the SFP. FW-1052 Message , is between high and low boundaries(High=, Low=). Current value is - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 471
indicates the maximum lifetime use of the SFP. Recommended Replace the SFP. Action FW-1113 Message , value changed. E_Ports go down each time you remove a cable or small form-factor pluggable (SFP). SFP failures switch is functioning normally. Fabric OS Message Reference 449 53-1002749 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 472
a value within the acceptable range. E_Ports go down each time you remove a cable or small form-factor pluggable (SFP). SFP failures also cause E_Ports to go changed. The following occurrences can cause a fabric reconfiguration: • Two switches with the same domain ID have connected to one another. • - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 473
Action Verify that all inter-switch link (ISL) cables are properly connected at both ends. Verify that the small form-factor pluggable (SFP) has not become faulty. An inexplicable fabric reconfiguration might be a transient error and might not require troubleshooting. Fabric OS Message Reference - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 474
changes has changed. Domain ID changes occur when there is a conflict of domain IDs in a single fabric and the principal switch must assign another domain ID to the switch. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 475
the high boundary. Domain ID changes occur when there is a conflict of domain IDs in a single fabric and the principal switch has to assign another domain ID to the switch. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 476
occur due to the following reasons: • Zone conflicts. • Domain conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. Recommended - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 477
occur due to the following reasons: • Zone conflicts. • Domain conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. Recommended - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 478
5 FW-1131 Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. FW-1131 Message , is above high boundary(High=, Low=). Current value is . Message Type LOG Severity - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 479
FW-1134 5 FW-1134 Message , is below low boundary(High=, Low=). Current value is . Message Type LOG Severity INFO Probable Cause Indicates that the number of fabric logins has fallen below the low boundary. Fabric logins occur when a port or device - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 480
fallen below the low boundary. SFP state changes occur when the SFP is inserted or removed. A low number of SFP state changes means that the switch is functioning normally. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 481
physical and hardware problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot them. A low number of link loss errors means that the switch is functioning normally - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 482
problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot small form-factor pluggable (SFP) or cable. Signal losses often create synchronization losses. 460 Fabric OS - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 483
FW-1165 5 Recommended Action Check both ends of your cable connection. Verify that the cable and SFPs are not faulty. If you continue to experience synchronization loss errors, troubleshoot your host bus adapter (HBA) and contact your switch service provider. FW-1165 Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 484
due to a faulty small form-factor pluggable (SFP) or cable. Signal losses often create synchronization losses. Recommended Action No action of signal generally indicates a physical problem. A low number of signal loss errors means that the switch is functioning normally. Recommended Action No - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 485
that the port experiences has risen above the high boundary. Loss of signal generally indicates a physical problem. Recommended Action Check both ends of your cable connection. Verify that the cable is not faulty. FW-1171 Message , is between high and low boundaries(High - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 486
protocol errors occur due to hardware problems. A low number of protocol errors means that the switch is functioning normally. Recommended Action errors occur due to hardware problems. Recommended Action Check both ends of your connection. Verify that your cable and small form-factor pluggables - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 487
port experiences has fallen below the low boundary. Invalid words usually indicate a hardware problem with a small form-factor pluggable (SFP) or cable. A low number of invalid words means that the switch is functioning normally. Recommended Action No action is required. Respond to this message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 488
range. Invalid words usually indicate a hardware problem with a small form-factor pluggable (SFP) or cable. Recommended Action No action is required. low boundary. A low number of invalid CRCs means that the switch is functioning normally. Recommended Action No action is required. Respond to - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 489
. Respond to this message as is appropriate to the particular policy of the end-user installation. Check your small form-factor pluggables (SFPs), cables, and connections for faulty hardware. Verify that all optical hardware is clean. FW-1184 Message , value has changed(High - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 490
5 FW-1185 FW-1185 Message , is below low boundary(High=, Low=). Current value is . Message Type LOG Severity INFO Probable Cause Indicates that the percentage of incoming traffic that the port experiences has fallen below the low - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 491
FW-1188 5 FW-1188 Message , value has changed(High=, Low=). Current value is . Message Type LOG Severity INFO Probable Cause Indicates that the percentage of outgoing traffic that the port experiences has changed. Recommended Action No - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 492
, has become an E_Port, has become an F_Port, has segmented, or has become a trunk port. A low number of port state changes means that the switch is functioning normally. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 493
the port experiences has changed. Link resets occur due to link timeout errors that indicate no frame activity. Recommended Action Check both ends of your cable connection. Verify if the cable and small form-factor pluggables (SFPs) are faulty. Fabric OS Message Reference 471 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 494
no frame activity. A low number of link resets means that the switch is functioning normally. Recommended Action Respond to this message as is and hardware problems can cause link resets to increase. Recommended Action Check both ends of your cable connection. Verify if the cable and small - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 495
Cause Indicates that the number of C3 transmit timeout frames is below the low threshold. A low number of C3 transmit timeout means that the switch is functioning normally. Recommended Action Respond to this message as is appropriate to the particular policy of the end-user installation. FW-1202 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 496
5 FW-1203 FW-1203 Message , is between high and low boundaries(High=, Low=). Current value is . Message Type LOG Severity INFO Probable Cause Indicates that the number of C3 transmit timeout frames is between the high and low thresholds. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 497
to five- or six-digit figures, because only large numbers of messages indicate a problem in this area. Recommended Action Verify that your optical components are clean and function properly. Replace deteriorating cables or small form-factor pluggables (SFPs). Check for damage from heat or age - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 498
end-user installation. A low level of invalid CRC errors means that the switch is functioning normally. FW-1218 Message , is above high boundary( for CRC errors indicate problems. Check for a faulty cable or deteriorated small form-factor pluggable (SFP). Replace the cable or the SFP if - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 499
fluctuations, and aging equipment. You should set your high boundaries to five- or six-digit figures, because only large numbers of messages indicate a problem in this area. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 500
-end performance monitor class helps you tune the fabric. To reduce CRC errors, experiment with alternative topologies and cabling schemes. Clean equipment, check temperatures, and replace old hardware. FW-1243 Message , is between high and low boundaries(High=, Low= - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 501
Current value is . Message Type LOG Severity INFO Probable Cause Indicates that the number of end-to-end word frames that the switch receives has fallen below the low boundary. Receive performance messages appear due to the number of word frames that travel from the configured S_ID - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 502
Current value is . Message Type LOG Severity INFO Probable Cause Indicates that the number of end-to-end word frames that the switch transmits has changed. Transmit performance messages appear due to the number of word frames that travel from the configured S_ID to the D_ID pair - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 503
value is . Message Type LOG Severity INFO Probable Cause Indicates that the number of end-to-end word frames that the switch transmits has risen above the high boundary. Transmit performance messages appear due to the number of word frames that travel from the configured S_ID to - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 504
5 FW-1273 FW-1273 Message , is below low boundary(High=, Low=). Current value is . Message Type LOG Severity INFO Probable Cause Indicates that the number of frame types or commands that the port receives has fallen below the low boundary. The port - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 505
been received from an unauthorized IP address. The TELNET_POLICY contains a list of IP addresses that are authorized to establish Telnet connections to switches in the fabric. Recommended Action No action is required. FW-1298 Message , is above high boundary(High=, Low= - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 506
been received from an unauthorized IP address. The TELNET_POLICY contains a list of IP addresses that are authorized to establish Telnet connections to switches in the fabric. Recommended Action No action is required. FW-1300 Message , value has changed(High=, Low= - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 507
received from an unauthorized IP address. The HTTP_POLICY contains a list of IP addresses that are authorized to establish browser connections to the switches in the fabric. Recommended Action No action is required. FW-1304 Message , value has changed(High=, Low= - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 508
address. The Simple Network Management Protocol policy (SNMP_POLICY) contains a list of IP addresses that are authorized to establish API connections to switches in the fabric. Recommended Action Execute the errShow command to determine the IP address that sent the request. Responses to security - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 509
IP address. The Simple Network Management Protocol policy (SNMP_POLICY) contains a list of IP addresses that are authorized to establish API connections to switches in the fabric. Recommended Action No action is required. FW-1308 Message , value has changed(High=, Low= - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 510
5 FW-1310 FW-1310 Message , is above high boundary(High=, Low=). Current value is . Message Type LOG Severity WARNING Probable Cause Indicates that the number of read SNMP (RSNMP) violations has risen above the high boundary. RSNMP violations - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 511
FW-1313 5 FW-1313 Message , is below low boundary(High=, Low=). Current value is . Message Type LOG Severity INFO Probable Cause Indicates that the number of write SNMP (WSNMP) violations has fallen below the low boundary. WSNMP violations indicate - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 512
=, Low=). Current value is . Message Type LOG Severity INFO Probable Cause Indicates that the number of SCSI Enclosure Services (SES) violations has fallen below the low boundary. SES violations indicate that a Small Computer System Interface (SCSI) Enclosure - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 513
>, Low=). Current value is . Message Type LOG Severity INFO Probable Cause Indicates that the number of SCSI Enclosure Services (SES) violations has changed from a value outside of the acceptable range to a value within the acceptable range. SES violations indicate that - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 514
serial violations has changed. Serial violations indicate that an unauthorized serial port request has been received. The SERIAL_POLICY contains a list of switch World Wide Names (WWNs) for which serial port access is enabled. Recommended Action Execute the errShow command to determine the WWN of - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 515
risen above the high boundary. Serial violations indicate that an unauthorized serial port request has been received. The SERIAL_POLICY contains a list of switch World Wide Names (WWNs) for which serial port access is enabled. Recommended Action Run the errShow command to determine the WWN of the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 516
violations has changed. Front panel violations indicate that an unauthorized front panel request has been received. The FRONTPANEL_POLICY contains a list of switch World Wide Names (WWNs) for which front panel access is enabled. Recommended Action Execute the errShow command to determine the WWN - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 517
the acceptable range. Front panel violations indicate that an unauthorized front panel request has been received. The FRONTPANEL_POLICY contains a list of switch World Wide Names (WWNs) for which front panel access is enabled. Recommended Action No action is required. FW-1332 Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 518
device tried to join the fabric. The DCC_POLICY allows for the specification of rules for binding device ports (typically HBA ports) to specific switch ports. DCC policies ensure that whenever a device performs a fabric login (FLOGI) request, the World Wide Name (WWN) specified in the FLOGI is - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 519
device tried to join the fabric. The DCC_POLICY allows for the specification of rules for binding device ports (typically HBA ports) to specific switch ports. DCC policies ensure that whenever a device performs a fabric login (FLOGI) request, the World Wide Name (WWN) specified in the FLOGI is - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 520
device tried to join the fabric. The DCC_POLICY allows for the specification of rules for binding device ports (typically HBA ports) to specific switch ports. DCC policies ensure that whenever a device performs a fabric login (FLOGI) request, the World Wide Name (WWN) specified in the FLOGI is - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 521
has been received from the primary fabric configuration server (FCS). When the primary FCS downloads a new configuration to other switches in the fabric, the packet is tagged with a timestamp. The receiving switch compares this timestamp to its current time. If the difference is too great, it - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 522
has been received from the primary fabric configuration server (FCS). When the primary FCS downloads a new configuration to other switches in the fabric, the packet is tagged with a timestamp. The receiving switch compares this timestamp to its current time. If the difference is too great, it - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 523
violations indicate that a packet with an invalid signature has been received from the primary fabric configuration server (FCS). When the primary FCS downloads a new configuration to the other switches in the fabric, the packet is signed using the private key of the primary FCS. The receiving - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 524
violations indicate that a packet with an invalid signature has been received from the primary fabric configuration server (FCS). When the primary FCS downloads a new configuration to the other switches in the fabric, the packet is signed using the private key of the primary FCS. The receiving - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 525
violations indicate that a packet with an invalid signature has been received from the primary fabric configuration server (FCS). When the primary FCS downloads a new configuration to the other switches in the fabric, the packet is signed using the private key of the primary FCS. The receiving - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 526
in the fabric, it first sends its certificate to all the switches in the fabric. The receiving switch must verify that the sender is the primary FCS switch and its certificate is signed by the Root CA recognized by the receiving switch. This counter keeps track of the number of packets received with - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 527
the number of authentication failures has fallen below the low boundary. Authentication failures can occur for many reasons. The switch on the other side may not support the protocol, have an invalid certificate, not be signed properly, or send unexpected packets. The port where authentication fails - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 528
the number of authentication failures has risen above the high boundary. Authentication failures can occur for many reasons. The switch on the other side may not support the protocol, have an invalid certificate, not be signed properly, or send unexpected packets. The port where authentication fails - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 529
(High=, Low=). Current value is . Message Type LOG Severity INFO Probable Cause Indicates that the number of switch link authentication protocol (SLAP) faulty packets has fallen below the low boundary. This counter keeps track of the number of unexpected SLAP - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 530
=, Low=). Current value is . Message Type LOG Severity INFO Probable Cause Indicates that the number of time service (TS) out-of-sync violations has fallen below the low boundary. Recommended Action No action is required. FW-1366 Message , is above - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 531
Unit>. Message Type LOG Severity INFO Probable Cause Indicates that the number of time service (TS) out-of-sync violations has changed from a value outside of the fabric, but it still has the WWN of the last primary FCS switch, it increments this counter and resets the WWN of the primary FCS - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 532
finds that there are no FCSs in the fabric, but it still has the WWN of the last primary FCS switch, it increments this counter and resets the WWN of the primary FCS to all zeroes. Recommended Action Responses to security-class messages depend on user - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 533
security database violations has changed. This violation indicates the number of secure switches with different version stamps have been detected. When a switch is in secure mode, it connects only to another switch that is in secure mode and has a compatible security database. A compatible security - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 534
tracks how many times commands allowed only on the primary fabric configuration server (FCS) switch have been executed on a non-primary FCS switch. There are many commands that can be executed only on the primary FCS switch, as well as one security command that can be executed only on a backup FCS - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 535
tracks how many times commands allowed only on the primary fabric configuration server (FCS) switch have been executed on a non-primary FCS switch. There are many commands that can be executed only on the primary FCS switch, as well as one security command that can be executed only on a backup FCS - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 536
Probable Cause Indicates that the flash memory usage percentage has changed. Flash memory increases and decreases slightly with normal operation of the switch. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 537
the flash memory usage percentage has risen above the high boundary. Flash memory increases and decreases slightly with normal operation of the switch. Recommended Action Remove some unwanted files to create some flash space. Execute the supportSave command to remove files from the kernel space - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 538
5 FW-1405 FW-1405 Message ,is above high boundary(High=, Low=). Current value is . Message Type AUDIT | LOG Class FW Severity INFO Probable Cause Indicates that the memory usage is below the low memory threshold. Recommended Action No action is - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 539
status changed from to . Message Type LOG Severity WARNING Probable Cause Indicates that the switch is not in a healthy state. This occurred because of a policy violation. Recommended Action Execute the switchStatusShow command to determine the policy violation - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 540
power supplies is greater than or equal to the policy set by the switchStatusPolicySet command. Recommended Action Replace the faulty power supply. FW-1428 Message Switch status change contributing factor Power supply: absent. Message Type LOG Severity WARNING Probable Cause - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 541
when the sensor value is not in the acceptable range or is faulty. Recommended Action Replace the field-replaceable unit (FRU) with the faulty temperature sensor. FW-1431 Message Switch status change contributing factor Fan: bad. Message Type LOG Severity WARNING Probable Cause - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 542
level of firmware to both CPs. Replace any faulty CPs. If you reset the micro-switch (the latch on the CP blade) on the active CP before the heartbeat was up on a power cycle, and the CPs came up non-redundant, then you should reboot the CPs again to clear the problem. FW-1434 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 543
or Buffer Limited Port is above the high boundary. Recommended Action Replace the faulty or deteriorating small form-factor pluggable (SFP). Execute list>). Message Type LOG Severity WARNING Probable Cause Indicates that the switch is not in a healthy state. This occurred because the number - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 544
. This occurred because the switch is offline. Recommended Action Execute the switchEnable command. FW-1440 Message state has changed to . Message Type LOG Severity INFO Probable Cause Indicates that the state of the specified field-replaceable unit (FRU) has changed - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 545
Message state has changed to . Message Type LOG Severity INFO Probable Cause Indicates that the state of the specified field-replaceable unit (FRU) has changed to inserted. This means that a FRU is inserted but not powered on. Recommended Action Verify that the event was - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 546
status marginal. When an AP blade is or has been present, the default value is 2 (out of service) indicating switch status is down or 1 (out of service) indicating switch status is marginal. Recommended Action To maintain full (2X) redundancy and proper monitoring by Fabric Watch, supply four - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 547
of core blade failures is greater than or equal to the policy set by the switchStatusPolicySet command. Recommended Action Replace the faulty core blade. FW-1448 Message Switch status change contributing factor Error ports: Error out of ports - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 548
. Occasionally, these errors occur due to software glitches. Persistent errors occur due to hardware problems. Recommended Action Check for concurrent loss of synchronization errors. Check the SFP and the cable. Then, enable the port using the portEnable command. 526 Fabric OS Message Reference - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 549
problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot small form-factor pluggable (SFP) or cable. Signal losses often create synchronization losses. Fabric OS Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 550
value within the acceptable range. Loss of signal generally indicates a physical problem. Recommended Action Frequent loss of signal generally indicates a physical problem. Check both ends of your cable connection. Verify that the cable and small form-factor pluggables (SFPs) are not faulty. 528 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 551
and crossed the lower threshold boundary to a value within the acceptable range. Invalid words usually indicate a hardware problem with a small form-factor pluggable (SFP) or cable. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 552
dropped the below upper threshold boundary to a value within the acceptable range. Invalid words usually indicate a hardware problem with a small form-factor pluggable (SFP) or cable. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 553
FW-1523 5 FW-1523 Message , has crossed lower threshold boundary to in between(High=, Low=). Current value is . Message Type LOG Severity INFO Probable Cause Indicates that the percentage of incoming traffic that the port experiences - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 554
5 FW-1526 FW-1526 Message , has dropped below upper threshold boundary to in between(High=, Low=). Current value is . Message Type LOG Severity INFO Probable Cause Indicates that the percentage of outgoing traffic that the port - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 555
to a value within the acceptable range. Link resets occur due to link timeout errors that indicate no frame activity at all. Both physical and hardware problems can cause link resets to increase. Recommended Action Respond to this message as is appropriate to the particular policy of the end-user - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 556
5 FW-1532 FW-1532 Message , has dropped below upper threshold boundary to in between(High=, Low=). Current value is . Message Type LOG Severity INFO Probable Cause Indicates that the number of C3 transmit timeout frames has dropped below - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 557
to a new version resets the bit because Port Fencing is not supported. Recommended Action No action is required. You are informed that the Port INFO Probable Cause Indicates that Fabric Watch is not monitoring the switch because MAPS is enabled. Recommended Action Verify that the event was - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 558
5 FW-3010 FW-3010 Message value has changed(High=, Low=). Current value is . Message Type LOG Severity INFO Probable Cause Indicates that the circuit utilization has changed. Recommended Action Respond to this message as is appropriate - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 559
FW-3013 5 FW-3013 Message is between high and low boundaries(High=, Low=). Current value is . Message Type LOG Severity INFO Probable Cause Indicates that the circuit utilization is between the high and low boundary thresholds. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 560
5 FW-3016 FW-3016 Message is above high boundary(High=, Low=). Current value is . Message Type LOG Severity WARNING Probable Cause Indicates the packet loss that the circuit experiences is above the high boundary threshold. Recommended - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 561
FW-3019 5 FW-3019 Message is below low boundary(High=, Low=). Current value is . Message Type LOG Severity INFO Probable Cause Indicates the number of state changes that the circuit experiences is below the low boundary level. The - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 562
for is changed to Minute as Seconds is not supported. Message Type LOG Severity INFO Probable Cause Indicates that the timebase for the class is changed implicitly to minutes because a seconds timebase is not supported. Recommended Action No action is required. 540 Fabric OS Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 563
CP blade by ejecting the card and reseating it. If the problem persists, replace the standby CP. HAM-1002 Message Standby CP is healthy. Message INFO Probable Cause Indicates that the switch has been restarted because of a user action or an error. The switch restart can be initiated by the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 564
the errShow command on both control processors (CPs) to view the error log for additional messages that may indicate reason for the switch restart. HAM-1005 Message HeartBeat Miss reached threshold. Message Type LOG Severity INFO Probable Cause Indicates that either the active CP Ethernet - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 565
. • The cold or warm recovery has failed. Recommended Action If auto-reboot is enabled, the switch will automatically restart. Otherwise, execute the reboot command to manually restart the switch. HAM-1008 Message Rebooting the system for recovery - auto-reboot is enabled. Message Type FFDC - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 566
is disabled. Message Type FFDC | LOG Severity CRITICAL Probable Cause Indicates that the recovery by auto-restart is disabled, therefore the switch needs to be manually restarted for recovery. This message is displayed if the event logged in HAM-1007 has occurred and auto-reboot is disabled - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 567
Cause Indicates that the software watchdog has detected termination of a restartable daemon, but could not restart the daemon. Recommended Action Manually initiate a restart or failover, if needed. HAM-1014 Message . Message Type LOG Severity CRITICAL Probable Cause Indicates - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 568
your switch service provider. HAMK-1002 Message Heartbeat down. Message Type LOG Severity INFO Probable Cause Indicates that the active control processor (CP) blade determined that the standby CP blade is down. This can be a result of a user-initiated action such as firmware download, the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 569
HAMK-1004 5 HAMK-1004 Message Resetting standby CP (double reset may occur). Message Type LOG Severity INFO Probable Cause Indicates that the standby control processor (CP) is being reset due to a loss of heartbeat. Typically, this message is displayed when the standby CP has been restarted. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 570
voltage is above threshold. Recommended Action Replace the faulty blade or switch (for non-bladed switches). HIL-1102 Message Slot - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 571
units (FRUs) and power supply FRU to verify that they are seated properly. If the problem persists, replace the fan FRU or the power supply FRU as necessary. HIL-1105 Message Switch error, () above threshold. Message Type LOG Severity ERROR Probable Cause - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 572
. Make sure that the area is well-ventilated and that the room temperature is within the operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Run the fanShow command to monitor the speed of the fan generating this error. If - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 573
to the hardware reference manual for your switch for the operational temperature range. Run the fanShow command to monitor the speed of the fan generating this error. If the fan continues to generate this message, replace the fan FRU. HIL-1204 Message Fan faulted, speed ( - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 574
problem can quickly cause the switch to overheat. This message is specific to non-bladed switches. Recommended Action Replace the fan field-replaceable is within the operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Use - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 575
is often preceded by a low speed error message. This problem can cause the switch to overheat. Recommended Action Replace the affected fan FRU immediately. HIL-1302 Message blowers failed or missing. Replace failed or missing blower assemblies immediately. Message Type LOG Severity - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 576
(FRUs) have failed. This message is often preceded by a low fan speed message. Recommended Action Replace the faulty fan FRUs immediately. HIL-1305 Message One or two fans failed. Replace failed fan FRUs immediately. Message Type LOG Severity ERROR Probable Cause Indicates that multiple fan - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 577
Cause Indicates that multiple fans have failed. This message is often preceded by a low fan speed message. Recommended Action Replace the faulty fan field-replaceable units (FRUs) immediately. HIL-1310 Message fan(s) faulty. Message Type LOG Severity WARNING Probable Cause Indicates that - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 578
faultiness. If the fan continues to generate this message, it indicates oscillation between faulty and non-faulty behavior. Replace the switch because the fan is not field-replaceable. HIL-1401 Message One fan FRU missing. Install fan FRU immediately. Message Type LOG Severity WARNING Probable - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 579
LOG Severity WARNING Probable Cause Indicates that all fan field-replaceable units (FRUs) have been removed. Recommended Action Install the temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Fabric - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 580
well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. If the message persists, replace the blade. HIL-1503 Message Slot , unit shutting down. Message Type - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 581
all fans are working properly. Replace any deteriorating fan field-replaceable units (FRUs). Make sure that the area is well-ventilated and that the room temperature is within the operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 582
. To help prevent future problems, make sure that all the fans are working properly. Make sure that the area is well-ventilated and that the room temperature is within the operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 583
switch. Refer to the hardware reference manual for your switch replaceable units (FRUs). Run the tempShow command to verify temperature values. If any sensor is too high, monitor the switch. Try rebooting or power cycling the switch. HIL-1602 Message Multiple temperature sensors failed. Service - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 584
. This message is applicable only to the Brocade 5100. Recommended Action Ensure the power cord is connected to the unit with a valid power source and then switch on the unit. If the problem persists, try reseating the unit. If the problem still persists, replace the FRU. 562 Fabric OS Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 585
HIL-1611 Message MISMATCH in PSU-FAN Air Flow direction. Replace PSU with fan air flows in same direction. System will system will shut down in two minutes. This message is applicable only to the Brocade 6510. Recommended Action Use the chassisShow command to check the airflow directions of the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 586
5 HIL-1650 HIL-1650 Message Unable to detect both WWN cards in chassis. Access to WWN halted. Message Type LOG Severity ERROR Probable Cause Indicates that one or both of the World Wide Name (WWN) cards is missing. Both WWN cards must be present for normal operation. Recommended Action Make - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 587
that the hello (HLO) message was incompatible with the value specified in the fabric shortest path first (FSPF) protocol. The Brocade switch will not accept FSPF frames from the remote switch. In Fabric OS, the HLO dead timeout value is not configurable, so this error can only occur when the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 588
Cause Indicates that the hello (HLO) message received was invalid and the frame was dropped. The Brocade switch will not accept fabric shortest path first (FSPF) frames from the remote switch. The switch has received an invalid HLO because either the domain or port number in the HLO message has an - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 589
Execute the firmwareDownload command to reinstall the firmware to your switch. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. Fabric OS Message Reference 567 53 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 590
Action Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. HSL-1001 Message Failed to acquire system MAC address pool. Message Type LOG Severity CRITICAL Probable Cause Indicates failure to - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 591
interface using the shutdown command and insert an SFP transceiver that is supported on the interface. After the SFP transceiver is inserted, re- a failure to initialize the Fabric OS State Synchronization (FSS) service. This error is caused by other system errors. Recommended Action Execute - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 592
shutdown command and re-insert the SFP transceiver. After the SFP transceiver is inserted, re-enable the interface using the no shutdown command. If the problem persists, contact your switch service provider. 570 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 593
Message Switch PID format has changed to . Message Type LOG Severity INFO Probable Cause Indicates that the port ID (PID) format was changed. Recommended Action No action is required. For more information on PID format, refer to the Fabric OS Administrator's Guide. HTTP - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 594
5 IBD-1000 IBD Messages IBD-1000 Message Slot Port GE: Maximum attempts to restart failed. Disabling port. Message Type LOG Severity ERROR Probable Cause Indicates that the specified port has crashed unexpectedly and restarting attempts have failed. Recommended - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 595
INFO Probable Cause Indicates that the gateway IP address has been changed manually or it was reconfigured automatically by the Dynamic Host Configuration Protocol action is required. IPAD-1002 Message Switch name has been successfully changed to . Message Type AUDIT | LOG Class - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 596
5 IPAD-1003 IPAD-1003 Message DNS parameters saved successfully. Message Type LOG Severity INFO Probable Cause Indicates that the Domain Name System (DNS) parameters are saved successfully. Recommended Action No action is required. IPAD-1004 Message DNS parameters removed successfully. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 597
add the license to your switch and activate it. IPS-1002 Message Failed to initialize rc = . Message Type LOG Severity ERROR Probable Cause Indicates that the initialization of a module within the IPS daemon failed. Recommended Action Download a new firmware version using the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 598
5 IPS-1004 IPS-1004 Message Port Config Mode Mismatch slot () port(ge): current mode is (). Message Type LOG Severity WARNING Probable Cause Indicates that configured port mode is different from the intended use. Recommended Action Change the port configuration (by - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 599
Indicates that the tunnel configuration failed because the FX8-24 blade is not at the correct revision to support IPSec enabled tunnels on VEs 22-31. Recommended Action Contact your switch vendor to acquire the correct hardware revision blade. Fabric OS Message Reference 577 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 600
with external iSNS server is disabled. Message Type LOG Severity INFO Probable Cause Indicates that the IP address of the Internet Storage Name Service (iSNS) server is zero. Therefore, peering is disabled. Recommended Action If you wish to enable the iSNS server, use the isnscCfg command to - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 601
Message Type LOG Severity INFO Probable Cause Indicates that a user has requested to re-register with the specified external Internet Storage Name Service (iSNS) server. Recommended Action No action is required. ISNS-1006 Message Start re-register with external iSNS server - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 602
INFO Probable Cause Indicates that peering with the external Internet Storage Name Service (iSNS) server was already started with the same configuration. Recommended Refer to the appropriate hardware reference manual for valid slot and port ranges. 580 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 603
is . Message Type LOG Severity INFO Probable Cause Indicates the current state of the Internet Storage Name Service (iSNS) client is enabled or disabled. Recommended Action No action is required. Use the fosConfig command to display, enable, or disable the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 604
operational; if not, change the switch key vault settings or resolve the operational problem at the key vault. KAC- switch and the key vault. Recommended Action Establish a trustee link between the switch and the key vault. Refer to the Fabric OS Encryption Administrator's Guide for instructions - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 605
the configured key vault is operational; if not, change the switch key vault settings or resolve the operational problem at the key vault. KAC-1008 Message Putting of TEP the primary and backup key vaults using instructions provided by the key vault provider. Fabric OS Message Reference 583 53 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 606
5 KAC-1010 KAC-1010 Message Archival for KeyID failed to . Error code=, string=. Message Type LOG Severity WARNING Probable Cause Indicates that archiving of Data Encryption Key (DEK) to the key vault failed. Recommended Action No action - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 607
ERROR Probable Cause Indicates that the Key Archive Client (KAC) is unable to communicate with the primary or backup key vault. Recommended Action Change the switch key vault settings and make sure the configured key vault is operational. Fabric OS Message Reference 585 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 608
switch key vault settings or resolve the operational problem at the key vault. KAC-1017 Message Error: KV parameter [] configured on BES is not supported key vault parameters on the Brocade Encryption Switch (BES) and the functionality supported by the key vault. Recommended - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 609
An abort signal is sent. Recommended Action Copy the warning message along with any core file information and contact your switch service provider. KSWD-1002 Message Detected termination of process :. Message Type FFDC | LOG Severity WARNING - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 610
memory size has exceeded the dump file size. Recommended Action Execute the supportSave command and reload the switch. If the problem persists, contact your switch service provider. KTRC-1002 Message Concurrent trace dumping. Message Type LOG Severity INFO Probable Cause Indicates that the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 611
attachment (ATA) dump device has exceeded. Recommended Action Execute the supportSave command and reload the switch. If the problem persists, contact your switch service provider. KTRC-1005 Message Trace initialization failed. . . Message Type - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 612
Error: Message queue create failed. Message Type LOG Severity ERROR Probable Cause Indicates that the Layer 2 system (L2SYS) encountered system service manager (SSM) message queue errors. Recommended Action Reboot or power cycle the switch. 590 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 613
access control (MAC) address table hash failed even after two hash changes on the specified chip. Recommended Action Reboot or power cycle the switch. L2SS-1006 Message MAC-address-table table on slot chip is 95 percent full. Message Type LOG Severity INFO Probable Cause - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 614
5 L2SS-1007 L2SS-1007 Message MAC-address-table on slot chip is less than 90 percent full. Message Type LOG Severity INFO Probable Cause Indicates that the media access control (MAC) address table on the specified chip is less than 90 percent full. Recommended Action No - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 615
L3SS-1004 5 L3SS Messages L3SS-1004 Message , : HW/Driver Error (possibly the CAM is full): , rc=. Message Type LOG Severity ERROR Probable Cause Indicates an error in the hardware or the driver of the Layer 3 subsystem (L3SS). L3SS may - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 616
that initialization of the specified module within the Link Aggregation Control Protocol (LACP) daemon has failed. Recommended Action Download a new firmware using the firmwareDownload command. LACP-1002 Message . Message Type LOG Severity ERROR Probable Cause Indicates that some - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 617
LANCE-1000 5 LANCE Messages LANCE-1000 Message Slot Port GE: Maximum attempts to restart failed. Disabling port. Message Type LOG Severity ERROR Probable Cause Indicates that the specified port has crashed unexpectedly and restarting attempts have failed. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 618
Cause Indicates that the Logical Fabric Manager service is disabled. Note that the Logical Fabric Manager service is enabled by the factory setting and is set to default. This will remove all prior Logical Fabric Manager configurations. This operation is not supported currently. Recommended - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 619
information using the supportsave command and contact the Brocade technical support. LFM-1005 Message Logical port disabled , and take appropriate corrective action. LFM-1006 Message The switch with domain with firmware version has joined the FID fabric - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 620
, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. LOG-1002 Message A log message was dropped. Message Type FFDC | LOG Severity WARNING Probable Cause Indicates that a message was - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 621
message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. LOG-1005 Message Log message has been disabled. Message Type AUDIT | LOG Class RAS - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 622
5 LOG-1006 LOG-1006 Message Log message has been enabled. Message Type AUDIT | LOG Class RAS Severity INFO Probable Cause Indicates that the specified message has been enabled for logging. Recommended Action No action is required. LOG-1007 Message Log - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 623
LOG-1009 5 LOG-1009 Message Internal Log message has been enabled for syslog logging. Message Type LOG Severity INFO Probable Cause Indicates that the specified internal message has been enabled for syslog logging. Recommended - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 624
. The valid link state ID is the same as the valid domain ID, with a range from 1 through 239. The switch will discard the record because it is not supported. Recommended Action No action is required. LSDB-1002 Message Local Link State Record reached max incarnation. Message Type LOG Severity - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 625
LSDB-1004 5 Recommended Action Run the switchDisable and switchEnable commands. A new local LSR is generated during the switch enable. LSDB-1004 Message No Link State Record for domain . Message Type LOG Severity WARNING Probable Cause Indicates that there is no link - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 626
5 MCAST_SS-1001 MCAST_SS Messages MCAST_SS-1001 Message Socket Error: () for socket the error code . Message Type LOG Severity ERROR Probable Cause Indicates that an error has occurred in the Linux socket. Recommended Action Restart the multicast subsystem - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 627
Message Type LOG Severity ERROR Probable Cause Indicates that the multicast subsystem (MCAST_SS) has encountered an error during a network service module (NSM) event. Recommended Action Restart the MCAST_SS daemon. MCAST_SS-1005 Message Message error: Invalid message type expecting - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 628
5 MCAST_SS-1007 MCAST_SS-1007 Message Initialization error: (). Message Type LOG Severity ERROR Probable Cause Indicates that the multicast subsystem (MCAST_SS) has encountered an error during initialization. Recommended Action Restart the MCAST_SS daemon. MCAST_SS-1008 Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 629
MCAST_SS-1010 5 MCAST_SS-1010 Message Message Queue error: (). Message Type LOG Severity ERROR Probable Cause Indicates that the multicast subsystem (MCAST_SS) has encountered the message queue errors. Recommended Action Restart the MCAST_SS daemon. MCAST_SS-1011 Message IDB - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 630
5 MCAST_SS-1014 Recommended Action Restart the MCAST_SS daemon. MCAST_SS-1014 Message Snooping DB error: () MAC Not found - VLAN MAC-addr . Message Type LOG Severity ERROR Probable Cause Indicates that the media access control (MAC) address lookup for the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 631
MCAST_SS-1017 5 MCAST_SS-1017 Message Learning error: () Invalid number for ifindex . Message Type LOG Severity ERROR Probable Cause Indicates that the multicast subsystem (MCAST_SS) has encountered an error while learning the media access control (MAC) addresses. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 632
5 MCAST_SS-1020 MCAST_SS-1020 Message List Error: () VLAN MAC group . Message Type LOG Severity ERROR Probable Cause Indicates that the multicast subsystem (MCAST_SS) has encountered an error during the List operation. Recommended Action Restart - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 633
) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. MFIC-1002 Message Chassis FRU header not programmed for switch NID, using defaults (applies only to FICON environments). Message Type LOG Severity INFO Probable Cause Indicates that - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 634
, and no action is required. IDID mode can be set using the configure command in the CLI or checking the Advanced Web Tools Switch Admin > Configure > Fabric > Insistent Domain ID Mode check box. The switch must be disabled to change the IDID mode. 612 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 635
corruption or tampering. Recommended Action Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. Fabric OS Message Reference 613 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 636
5 MPTH-1001 MPTH Messages MPTH-1001 Message Null parent, lsId = . Message Type LOG | FFDC Severity ERROR Probable Cause Indicates that a null parent was reported. The minimum cost path (MPATH) uses a tree structure in which the parent is used to connect to the root of the tree. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 637
MQ-1004 5 MQ Messages MQ-1004 Message mqRead, queue = , queue ID = , type = . Message Type LOG Severity ERROR Probable Cause Indicates an unexpected message has been received in the specified message queue. The queue name value is always fspf_q. The queue - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 638
5 MQ-1006 MQ-1006 Message queue : msg too long (:). Message Type LOG Severity WARNING Probable Cause Indicates the incoming message size is larger than the message queue size. Recommended Action No action is required. 616 Fabric OS Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 639
but not PL by: Set the flag for the MS platform service. • GCAP Rejected (reason =BUSY) by: Execute the firmwareDownload command to upgrade the firmware level on the switch to a level that supports reliable commit service (RCS). RCS is supported in Fabric OS v2.6, v3.1 and later, and v4.1 and later - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 640
, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. MS-1004 Message MS detected ONLY 1 Domain(d=). Message Type LOG Severity INFO Probable Cause Indicates - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 641
, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. MS-1008 Message MS Failure while initializing . Message Type LOG Severity ERROR Probable Cause Indicates that the Management - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 642
SAN hardware problems such as bad cables or small form-factor pluggable (SFP) transceivers. If the message persists, replace hardware. the supportSave command and contact your switch service provider. MS-1022 Message Management Server Platform Service . Message Type - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 643
. Message Type LOG Severity INFO Probable Cause Indicates that the Management Server (MS) topology discovery service is being enabled or disabled. Recommended Action No action is required. MS-1024 Message Management Server Access Control List is Updated. Message Type - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 644
the specified E_Port connected to the specified domain because an implicit enable operation of the MS platform service has been blocked. Recommended Action Enable MS platform service on the switch and re-enable the port to join the fabric. MS-1027 Message Fabric Name - configured - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 645
MS-1029 5 MS-1029 Message Duplicate Fabric Name - matching with FID . Message Type AUDIT | LOG Class FABRIC Severity ERROR Probable Cause Indicates that the configured fabric name is already used for another partition. Recommended Action Select a different fabric - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 646
transfer, or receiving error in the socket. Recommended Action If this is a bladed switch, execute the haFailover command. If the problem persists or if this is a non-bladed switch, download a new firmware version using the firmwareDownload command. 624 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 647
MSTP-2001 5 MSTP-2001 Message . Message Type LOG Severity INFO Probable Cause Indicates that the multiple spanning tree protocol (MSTP) bridge mode has changed. Recommended Action No action is required. MSTP-2002 Message . My Bridge ID: Old - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 648
5 MSTP-2004 MSTP-2004 Message MSTP instance is deleted. Message Type LOG Severity INFO Probable Cause Indicates that the specified multiple spanning tree protocol (MSTP) instance has been deleted. Recommended Action No action is required. MSTP-2005 Message VLAN is < - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 649
• 2 - Database Exchange • 3 - Database Acknowledge Wait • 4 - Database Wait • 5 - Full If this error occurs repeatedly, then there is a problem in the protocol implementation between two switches. Recommended Action Run the nbrStateShow command to check the neighbor state of the port listed in the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 650
• 2 - Database Exchange • 3 - Database Acknowledge Wait • 4 - Database Wait • 5 - Full If this error occurs repeatedly, then there is a problem in the protocol implementation between two switches. Recommended Action Run the nbrStateShow command to check the neighbor state of the port listed in the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 651
connected to the local switch. NS-1002 Message Remote switch 0x has firmware revision lower than 2.2: which is not supported. Message Type LOG Severity - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 652
download so that the active and standby CPs have the same firmware version. Reduce the local device count to follow the capability of the earliest version of firmware. NS-1005 Message Zone size of has over the supporting limit of for the remote switch - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 653
. Message Type LOG Severity WARNING Probable Cause Indicates that a logical inter-switch link (LISL) is detected in a traffic isolation (TI) zone. logged in with node World Wide Node Name (WWNN) as zero. Brocade Network Advisor (BNA) will not show the port connectivity. Recommended Action - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 654
on the specified port that has devices as members of a quality of service (QoS) zone. Recommended Action Remove the CS_CTL configured devices from the disabled traffic isolation (TI) zone has been detected in a base switch fabric. Recommended Action Enable the failover flag or remove the TI zone - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 655
NSM-1001 5 NSM Messages NSM-1001 Message Interface is online. Message Type LOG Severity INFO Probable Cause Indicates that the specified interface has come online after the protocol dependencies are resolved. Recommended Action No action is required. NSM-1002 Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 656
5 NSM-1003 NSM-1003 Message Interface is link down. Message Type LOG Severity INFO Probable Cause Indicates that the specified interface has gone offline because the link is down. Recommended Action Check whether the connectivity between the peer ports is proper, and the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 657
Recommended Action No action is required. NSM-1007 Message Chassis is . Message Type LOG Severity INFO Probable Cause Indicates that the chassis has been enabled or disabled. Recommended Action No action is required. NSM-1008 Message Blade () is . Message Type - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 658
5 NSM-1010 NSM-1010 Message InterfaceMode changed from to for interface . Message Type LOG Severity INFO Probable Cause Indicates that the interface mode has been changed. Recommended Action No action is required. NSM-1011 Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 659
NSM-1013 5 NSM-1013 Message VLAN classifier group is deleted. Message Type LOG Severity INFO Probable Cause Indicates that the specified VLAN classifier group has been deleted. Recommended Action No action is required. NSM-1014 Message VLAN classifier rule is created. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 660
5 NSM-1017 Recommended Action No action is required. NSM-1017 Message Interface is on interface . Message Type LOG Severity INFO Probable Cause Indicates that the logical interface member list has been changed. Recommended Action No action is - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 661
NSM-1020 5 NSM-1020 Message Interface is administratively down. Message Type LOG Severity INFO Probable Cause Indicates that the administrative status of the specified interface has changed to down. Recommended Action No action is required. Fabric OS Message Reference 639 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 662
5 ONMD-1000 ONMD Messages ONMD-1000 Message LLDP is enabled. Message Type LOG Severity INFO Probable Cause Indicates that the link layer discovery protocol (LLDP) is enabled globally. Recommended Action No action is required. ONMD-1001 Message LLDP is disabled. Message Type LOG Severity - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 663
ONMD-1003 5 ONMD-1003 Message LLDP is enabled on interface . Message Type LOG Severity INFO Probable Cause Indicates that the link layer discovery protocol (LLDP) is enabled on the specified interface. Recommended Action No action is required. ONMD-1004 Message LLDP is - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 664
Action Execute the firmwareDownload command to reinstall the firmware. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. 642 Fabric OS Message Reference 53-1002749 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 665
Action Execute the firmwareDownload command to reinstall the firmware. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. Fabric OS Message Reference 643 53-1002749 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 666
Action Execute the firmwareDownload command to reinstall the firmware. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. 644 Fabric OS Message Reference 53-1002749 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 667
Action Execute the firmwareDownload command to reinstall the firmware. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. Fabric OS Message Reference 645 53-1002749 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 668
Action Execute the firmwareDownload command to reinstall the firmware. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. 646 Fabric OS Message Reference 53-1002749 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 669
to be replicated. PDM-1021 Message Failed to download area port map. Message Type LOG Severity WARNING Probable firmware. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 670
with its peer because the firmware does not support IPv6. Recommended Action Configure the local switch with IPv4 addresses. PDM-1023 peer because the Domain Name Service (DNS) is configured with IPv6 addresses. IPv6 is not supported by older firmware. Recommended Action Configure DNS with - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 671
with its peer because the Lightweight Directory Access Protocol (LDAP) server is configured with IPv6 addresses. IPv6 is not supported by older firmware. Recommended Action Configure the LDAP server with IPv4 addresses. PDM-1026 Message User defined roles configured. Message Type LOG - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 672
5 PDTR-1001 PDTR Messages PDTR-1001 Message . Message Type LOG Severity INFO Probable Cause Indicates that information has been written to the panic dump files. The watchdog register codes are as follows: • 0x10000000 - The watchdog timer (WDT) forced a core reset. • - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 673
manually using the reboot command. Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service does not solve the problem. If the problem persists, replace the CP. Fabric OS Message Reference 651 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 674
hang was detected. Recommended Action Replace the field-replaceable unit (FRU). PLAT-1004 Message Switch has older FPGA rev 0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 675
failed. Error message: . Message Type LOG Severity WARNING Probable Cause Indicates that the switch with the specified fabric ID (FID) was not created. Recommended Action Refer to the Error Message string displayed in the message for possible action. PMGR- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 676
. Error message: . Message Type LOG Severity WARNING Probable Cause Indicates an unsuccessful attempt to move the ports to the specified switch. Recommended Action Refer to the Error Message string displayed in the message for possible action. PMGR-1007 Message Attempt to change - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 677
failed. Error message: Message Type LOG Severity WARNING Probable Cause Indicates a failed attempt to change the base switch. Recommended Action Refer to the Error Message string displayed in the message for possible action. Fabric OS Message Reference 655 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 678
5 PMGR-1011 PMGR-1011 Message Attempt to move port(s) to switch succeeded. Message Type LOG Severity INFO Probable Cause Indicates a successful attempt to move the ports to the specified switch. Recommended Action No action is required. 656 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 679
set threshold on the port. This problem is typically related to hardware. Recommended Action Check and replace (if necessary) the hardware attached to both ends of the specified port number, including: • The media (SFPs) • The cable (fiber optic or copper inter-switch link (ISL)) • The attached - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 680
Probable Cause Indicates the specified port is configured to be an L_Port, but the port does not support L_Port. If an L_Port is connected, then the port will be disabled because the port does not support L_Port. If an E_Port or F_Port is connected, then the port will not come up because - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 681
. PORT-1010 Message Port (ID: ) QoS is disabled. Message Type LOG Severity INFO Probable Cause Indicates that the port quality of service (QoS) is disabled due to the best effort setting on the 4 Gbps or 8 Gbps long distance platform. Recommended Action No action is required - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 682
If it does not, reboot or power cycle the switch to reinitiate the firmware. PS-1001 Message Advanced Performance Monitoring configuration updated due Action No action is required. Refer to the Fabric OS Administrator's Guide for more information about the PID format. PS-1002 Message Failed to - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 683
restoring configuration has attempted to set the end-to-end monitoring mask on at least one inter-switch link (ISL) port. Recommended Action No action is required. End-to-end monitoring is not supported on ISL ports when ISL monitoring is enabled. ISL monitoring can only be disabled through the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 684
-to-end monitors are configured on the switch. Recommended Action Delete end-to-end monitors on the switch and re-install the fabric mode Top fabric. Recommended Action Top Talker cannot be installed on a fabric with FCR service enabled. In case Top Talker must be installed on a fabric, disable - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 685
PS-1009 5 PS-1009 Message Failed to add the device updates in condb database. Message Type LOG Severity WARNING Probable Cause Indicates that the fabric has more than the allowed number of devices. Recommended Action Reduce the number of devices configured in the fabric to be within the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 686
Message Port Swap feature enabled. Message Type LOG Severity INFO Probable Cause Indicates the port swap feature has been enabled in the switch. Recommended Action No action is required. PSWP-1003 Message Port Swap feature disabled. Message Type LOG Severity INFO Probable Cause Indicates - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 687
number . Message Type LOG Severity WARNING Probable Cause Indicates the bladeSwap command failed on access to configuration data. Recommended Action Retry the command. If the failure persists, contact your switch service provider. Fabric OS Message Reference 665 53 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 688
code from fabosInit> in switch number . Message Type LOG Severity WARNING Probable Cause Indicates the bladeSwap command failed on access to switch context. Recommended Action Retry the command. If the failure persists, contact your switch service provider. 666 Fabric - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 689
Action Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. RAS-1002 Message First failure data capture (FFDC) maximum storage size ( MB) was reached. Message Type LOG - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 690
command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. RAS-1006 Message Support data file () automatically transferred to remote address ' '. Message Type - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 691
RAS-2001 5 RAS-2001 Message Audit message log is enabled. Message Type LOG | AUDIT Class RAS Severity INFO Probable Cause Indicates that the audit message log has been enabled. Recommended Action No action is required. RAS-2002 Message Audit message log is disabled. Message Type LOG | - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 692
5 RAS-3001 RAS-3001 Message USB storage device plug-in detected. Message Type LOG Severity INFO Probable Cause Indicates that the USB storage device plug-in has been detected. Recommended Action No action is required. RAS-3002 Message USB storage device enabled. Message Type LOG Severity - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 693
Recommended Action No action is required. RAS-3005 Message CLI: . Message Type AUDIT Class CLI Severity INFO Probable Cause Indicates that the specified command was executed on console. Recommended Action No action is required. RAS-3005 5 Fabric OS Message Reference 671 53 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 694
v4.1 and later. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. RCS-1002 Message RCS has been enabled. Message Type LOG Severity INFO Probable Cause Indicates that the reliable commit service (RCS) feature has been enabled. RCS must be capable - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 695
that the specified application did not register with reliable commit service (RCS). Recommended Action Run the haShow command to view and later. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. RCS-1005 Message Phase , - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 696
Probable Cause Indicates that the specified remote domain is requested to go offline to take it out of the fabric because it does not support reliable commit service (RCS). Recommended Action Run the fabricShow command to verify that the remote domain is out of the fabric. 674 Fabric OS Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 697
the rcsInfoShow command to view RCS capability of the switch. Investigate for routing issue or check the cabling, and re-enable the disabled E_Ports to attempt another Action Execute the supportSave command and contact your switch service provider. Fabric OS Message Reference 675 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 698
Type LOG | FFDC Severity WARNING Probable Cause Indicates that the specified remote domain is RCS-incapable. Recommended Action Execute the supportSave command and contact your switch service provider. 676 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 699
RKD-1001 5 RKD Messages RKD-1001 Message operation . Target: , Initiator: , LUN ID: . SessionId:/. Message Type - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 700
5 RKD-1004 RKD-1004 Message Message: . Message Type LOG Severity INFO Probable Cause Indicates the generic re-key message. Recommended Action No action is required. RKD-1005 Message LUN with LSN: does no have metadata. Make note of key ID - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 701
RMON-1001 5 RMON Messages RMON-1001 Message RMON rising threshold alarm from SNMP OID . Message Type LOG Severity INFO Probable Cause Indicates that the threshold level was exceeded for the sample type of the remote monitoring (RMON) alarm. Recommended Action Check the traffic on the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 702
faulty credentials. Recommended Action Enter the correct user name and password from the Fabric Access API host. RPCD-1002 Message Missing Indicates the Secure Sockets Layer (SSL) certificate file configured on the switch could not be accessed because root did not have read-level access. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 703
accessing private key file. Secure RPCd is disabled. Message Type LOG Severity WARNING Probable Cause Indicates the private key file configured on the switch could not be accessed because the root did not have read-level access. Recommended Action Change the file system access level for the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 704
5 RPCD-1007 Recommended Action Run the secCertUtil command to install a valid private key file. 682 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 705
RTE-1001 5 RTE Messages RTE-1001 Message Detected route inconsistency. It may cause connectivity issues. If such issues arise, bounce all ISLs and ICLs on this chassis. Message Type LOG Severity WARNING Probable Cause Indicates that the constraints that are used to determine the paths for - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 706
specified domain ID is offline, enable the switch using the switchEnable command. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. 684 Fabric OS Message Reference - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 707
reachable. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. Fabric OS Message Reference 685 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 708
hung daemon, the software watchdog will cause the daemon to dump the core and reboot the switch. In this case, execute the supportSave command to send the core files using FTP to the supportSave command and contact your switch service provider. 686 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 709
hung daemon, the software watchdog will cause the daemon to dump the core and reboot the switch. In this case, execute the supportSave command to send the core files using FTP to the supportSave command and contact your switch service provider. Fabric OS Message Reference 687 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 710
, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. SEC-1002 Message Security data fails: . Message Type LOG Severity ERROR Probable Cause Indicates that the receiving - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 711
and that the failed switch encountered an error accepting the database download. The primary switch will segment the failed switch after 30 tries. FTP transfers; then execute the supportSave command and contact your switch service provider. SEC-1005 Message Primary FCS receives data request from - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 712
was reported. The IP address of the unauthorized host is displayed in the message. Recommended Action Check for unauthorized access to the switch through the HTTP connection. SEC-1009 Message Security violation: Unauthorized host with IP address tries to - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 713
distribute the database from a non-primary switch. Recommended Action Resolve the specified error Action Check for unauthorized access to the switch through the SSH connection. SEC-1022 Message key infrastructure (PKI) objects exist on the switch. If the private key does not exist, follow - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 714
fabric configuration server (FCS) distributes the security database to the other switches in the fabric, and then local validation finds the error in fabric configuration server (FCS) distributes the security database to the other switches in the fabric, and then local validation finds the error in - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 715
fabric configuration server (FCS) distributes the security database to the other switches in the fabric, and then local validation finds the error in fabric configuration server (FCS) distributes the security database to the other switches in the fabric, and then local validation finds the error in - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 716
command. Only the secPolicyCreate command supports use of the asterisk for adding switches to policies. Recommended Action Run the secPolicyAdd command using a valid switch identifier (WWN, domain ID, or switch name) to add specific switches to the Switch Connection Control (SCC) policy. 694 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 717
SEC-1034 5 SEC-1034 Message Invalid member . Message Type LOG Severity ERROR Probable Cause Indicates the input list has an invalid member. Recommended Action Verify the member names, and input the correct information. SEC-1035 Message Invalid device WWN . - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 718
5 SEC-1038 Recommended Action Run the command again using the standard WWN format; 16 hexadecimal digits grouped as 8 colon-separated pairs, for example, 50:06:04:81:D6:F3:45:42. SEC-1038 Message Invalid domain . Message Type LOG Severity ERROR Probable Cause Indicates an invalid - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 719
SEC-1041 5 SEC-1041 Message Invalid port member in portlist (). . Message Type LOG Severity ERROR Probable Cause Indicates the port member is invalid for one of the following reasons: • The value is not a number. • The value is too long. Valid numbers must be - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 720
LOG Severity ERROR Probable Cause Indicates the specified member is a duplicate in the input list. The list can be a policy list or a switch member list. Recommended Action Do not specify any duplicates. SEC-1045 Message Too many port members. Message Type LOG Severity ERROR Probable Cause - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 721
fabric configuration server (FCS) distributes the security database to the other switches in the fabric, and then local validation finds the error in fabric configuration server (FCS) distributes the security database to the other switches in the fabric, and then local validation finds the error in - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 722
of the security database. This can only occur when the primary fabric configuration server (FCS) distributes the security database to the other switches in the fabric, and then local validation finds these error in the security database. This is a rare occurrence. Recommended Action Run the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 723
fabric configuration server (FCS) distributes the security database to the other switches in the fabric, and then local validation finds the error in fabric configuration server (FCS) distributes the security database to the other switches in the fabric, and then local validation finds the error in - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 724
Recommended Action Run the supportFtp - e command to FTP files from the switch and remove them from the flash memory. SEC-1062 Message Invalid number that either no domains or domains more than the maximum number supported are specified. Recommended Action Enter the correct number of domains. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 725
Action Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. SEC-1071 Message No new security policy data to apply. Message Type LOG Severity ERROR Probable Cause Indicates that no changes - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 726
Action Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. SEC-1073 Message No FCS policy in list. Message Type LOG Severity ERROR Probable Cause Indicates the specific policy type is - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 727
Re-enable the current zone configuration for the change to take effect. SEC-1077 Message Failed to activate new policy set on all switches. Message Type LOG Severity ERROR Probable Cause Indicates the policy could not be activated. Possible reasons that the policy could not be activated - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 728
of the security database. This can only occur when the primary fabric configuration server (FCS) distributes the security database to the other switches in the fabric, and then local validation finds the error in the security database. This is a rare occurrence. Recommended Action Run the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 729
of the security database. This can only occur when the primary fabric configuration server (FCS) distributes the security database to the other switches in the fabric, and then local validation finds the error in the security database. This is a rare occurrence. Recommended Action Run the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 730
5 SEC-1084 SEC-1084 Message Name exists for different type . Message Type LOG Severity ERROR Probable Cause Indicates the specified policy already exists. Recommended Action No action is required. SEC-1085 Message Failed to create . Message Type LOG Severity - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 731
bytes. Message Type LOG Severity ERROR Probable Cause Indicates the security database has more data than can be distributed to some of the switches in the fabric. Recommended Action Reduce the number of entries in the security policies to decrease the security database size. SEC-1088 Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 732
fabric configuration server (FCS) distributes the security database to the other switches in the fabric, and then local validation finds the error in fabric configuration server (FCS) distributes the security database to the other switches in the fabric, and then local validation finds the error in - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 733
fabric configuration server (FCS) distributes the security database to the other switches in the fabric, and then local validation finds that there is fabric configuration server (FCS) distributes the security database to the other switches in the fabric, and then local validation finds the error in - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 734
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. SEC-1098 Message No FCS list. Message Type LOG Severity ERROR Probable Cause Indicates the specified policy could - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 735
. Please retry later. Message Type LOG Severity ERROR Probable Cause Indicates the security enable failed on the fabric because one or more switches in the fabric are busy. Recommended Action Verify that the security event was planned. If the security event was planned, run the secFabricShow - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 736
Probable Cause Indicates the switch failed to download a certificate, security database, or policies. This can happen when the switch does not get Guide. SEC-1105 Message Fail to disable secure mode on all switches. Message Type LOG Severity ERROR Probable Cause Indicates the switch failed - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 737
Cause Indicates that some public key infrastructure (PKI) objects on the switch are not in a valid state, and a signature operation failed. Recommended for re-creating PKI objects outlined in the Fabric OS Administrator's Guide. SEC-1107 Message Stamp is 0. Message Type LOG Severity INFO - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 738
entry in the Active Security policies, and the same as the current active FCS list in the switch. Message Type LOG Severity ERROR Probable Cause Indicates either a security policy download was attempted with an active policy that does not have the fabric configuration server (FCS) policy as - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 739
an attempted secFcsFailover, no primary FCS is present in the fabric. Recommended Action Run the secFabricShow command to verify that all switches in the fabric are in the ready state. When all switches are in the ready state, retry the operation. Fabric OS Message Reference 717 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 740
set . Message Type LOG Severity INFO Probable Cause Indicates the switch failed to save the data received by the primary fabric configuration server (FCS) switch. This data can be an FCS password, a non-FCS password, SNMP data, or multiple user authentication data. Recommended Action Run - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 741
security policy. SEC-1121 Message Time is out of range when . Message Type LOG Severity ERROR Probable Cause Indicates the time on the switch is not synchronized with the primary fabric configuration server (FCS), the data packet is corrupted, or a replay attack is launched on the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 742
INFO Probable Cause Indicates the security database was successfully downloaded from the primary fabric configuration server (FCS). Recommended Action 1130 Message The Primary FCS has failed over to a new switch. Message Type LOG Severity INFO Probable Cause Indicates a fabric configuration - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 743
sent from the primary fabric configuration server (FCS) switch. This message usually indicates that the data package is corrupted, the time stamp on the package is out of range as a result of a replay attack or out-of-sync time service, or the signature verification failed. Signature verification - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 744
fabric configuration server (FCS) switch received a security database download. Recommended Action Verify that the switch. This message usually indicates that the data package is corrupted, the time stamp on the package is out of range as a result of a replay attack or out-of-sync time service - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 745
names for the specified policies have changed. • The passwords have changed for the specified accounts. • The switches in the fabric to be enabled. If all switches are capable, it is automatically enabled. For any switch that does not support RCS, obtain the latest firmware version from your switch - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 746
not be able to change the index/area because the new policy database exceeds the maximum size. This message can also be caused when the switch is short of memory. The status values can be either defined, active, or both. A negative value means that a policy set was failed by the daemon - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 747
command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. SEC-1158 Message Invalid name . Message Type LOG Severity INFO Probable Cause Indicates the specified name is invalid. The name can be - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 748
Type LOG Severity ERROR Probable Cause Indicates the attempt to enable security is made on a switch that is not present in the fabric configuration server (FCS) list. Recommended Action Add the switch to the FCS policy list when using the lockdown option to enable security. SEC-1165 Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 749
was planned. If the security event was planned, retry fabric configuration server (FCS) failover after the current failover has completed, if this switch should become the primary FCS. If the security event was not planned, take appropriate action as defined by your enterprise security policy. SEC - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 750
of the security database. This can only occur when the primary fabric configuration server (FCS) distributes the security database to the other switches in the fabric, and then local validation finds the error in the security database. This is a rare occurrence. Recommended Action Run the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 751
. Message Type LOG Severity ERROR Probable Cause Indicates the fabric configuration server (FCS) or non-FCS password could not be set. Recommended Action Verify all switches in the fabric are in time synchronization with the primary FCS and that no external entity is trying to access the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 752
Indicates the primary fabric configuration server (FCS) failed to generate a new version stamp because the fabric was not stable. Recommended Action Verify all switches in the fabric are in time synchronization with the primary FCS and that no external entity is trying to access the fabric. When - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 753
, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. SEC-1184 Message configuration change, action , server ID . Message Type LOG - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 754
policy. SEC-1188 Message Security violation: Unauthorized device tries to FLOGI to index/area of switch . Message Type LOG Severity INFO Probable Cause Indicates a Device Connection Control (DCC) security violation was reported. The specified - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 755
SEC-1189 5 SEC-1189 Message Security violation: Unauthorized host with IP address tries to do SNMP write operation. Message Type LOG Severity INFO Probable Cause Indicates an SNMP security violation was reported. The specified unauthorized host attempted to perform a write SNMP - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 756
The error message lists the violating IP address. Verify that this IP address is being used by a valid switch admin. Use the correct password. SEC-1194 Message This switch does not have all the required PKI objects correctly installed. Message Type LOG Severity WARNING Probable Cause Indicates - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 757
. Message Type LOG Severity WARNING Probable Cause Indicates the default switch accounts admin and user do not exist on the switch when enabling security. Recommended Action Reset the default admin and user account names on the switch that reported the warning and retry enabling security. SEC - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 758
. An attempt was made to access the serial console on the specified switch instance when it is disabled. Recommended Action Check to see if an authorized access attempt is being made on the console. If so, add the switch WWN to the serial policy. If the host is not allowed access to the fabric - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 759
a management server (MS) operation security violation was reported. An MS device operation occurred on a non-primary fabric configuration server (FCS) switch. Recommended Action Check the management server policy and verify the connection is allowed. If the connection is allowed but not specified - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 760
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. SEC-1253 Message Bad DCC interface state during , state=. Message Type LOG Severity ERROR Probable Cause Indicates an - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 761
Action Turn off VC-encoded mode before enabling security. SEC-1301 Message This switch is in interop mode. Security is not supported. Message Type LOG Severity INFO Probable Cause Indicates the switch is enabled in interop mode. Recommended Action Disable interop mode using the interopMode - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 762
Recommended Action Run the firmwareDownload command to update the firmware to the latest version for your specific switch. Verify the firmware you are installing supports the Brocade Secure Fabric OS feature. SEC-1304 Message This switch has no security license. Message Type LOG Severity INFO - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 763
validate PKI objects occurs, follow the steps for re-creating PKI objects outlined in the Fabric OS Administrator's Guide. If PKI objects are valid, verify that an unauthorized switch is not trying to access the fabric. SEC-1307 Message server - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 764
for the reliable commit service (RCS) transaction to complete. Recommended Action Verify if there are any reliable commit service (RCS) or Reliable the fabric because one or more switches in the fabric have password policies that are not set to the default values. Recommended Action Verify the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 765
set to default values. Message Type LOG Severity INFO Probable Cause Indicates the password configuration parameters were set to default values. Recommended system to fix this error. If the problem persists, contact your switch service provider. Fabric OS Message Reference 743 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 766
to the fabric, as specified by domain number, have a conflicting policy with the local switch. Recommended Action Check the conflicting policy and make the new switches and the local switch policies the same. SEC-1317 Message Inconsistent fabric, rejecting transaction Message Type LOG Severity - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 767
tries to join a fabric with strict fabric wide policy. Message Type LOG Severity WARNING Probable Cause Indicates that a domain not supporting an access control list (ACL) policy tried to join a fabric with the strict fabric-wide policy. Recommended Action No action is required - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 768
failed on the fabric because the switch has a conflicting configuration such as Cause Indicates this fabric is not able to support a Device Connection Control (DCC) policy with Indicates the specified key is ignored during configuration download. Recommended Action Verify the event was planned. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 769
Message Type LOG Severity INFO Probable Cause Indicates the reliable commit service (RCS) transaction failed with the specified reason code. Recommended your enterprise security policy. SEC-1325 Message Security enforcement: Switch connecting to port is not authorized - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 770
command failed on the fabric because the Authentication Policy is enabled on the switch. Recommended Action Verify the security event was planned. If the security event ; then execute the supportSave command and contact your switch service provider. 748 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 771
: . Message Type LOG Severity ERROR Probable Cause Indicates the secModeEnable command failed on the fabric because default IP filter policies are not active on the switch, or an active transaction exists on IP filter policies. Recommended Action Verify the security event was planned - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 772
ERROR Probable Cause Indicates there was an attempt to distribute PWD or IPFILTER databases from the fabric to a switch that is VF-enabled Recommended Action Disable VF on all the switches that have VF-enabled if PWD or IPFILTER databases need to be distributed. SEC-1334 Message SSH Daemon is - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 773
, as specified by domain number, have a conflicting policy with the local switch. Recommended Action Check the conflicting policy and make the new switches and the local switch policies the same. SEC-1337 Message Plain-text password is sent during console login Message Type AUDIT | LOG Class - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 774
attempt to distribute AUTH databases with switch policy (Off/Passive) from the fabric to a switch that has Inflight Encryption enabled Recommended security policy has been saved. • A security policy has been aborted. • A non-FCS password has changed. 752 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 775
SEC-3003 5 Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. SEC-3003 Message Event: , Status: success, - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 776
5 SEC-3006 Recommended Action Verify the addition of members to the policy was planned. If the addition of members was planned, no action is required. If the addition of members was not planned, take appropriate action as defined by your enterprise security policy. SEC-3006 Message Event: < - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 777
SEC-3009 5 Recommended Action Verify the modification was planned. If the modification was planned, no action is required. If the modification was not planned, take appropriate action as defined by your enterprise security policy. SEC-3009 Message Event: , Status: success, Info: - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 778
Message Event: , Status: success, Info: Temp Passwd on domain [] for account [ - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 779
SEC-3015 5 Recommended Action Verify the RADIUS configuration was changed intentionally. If the RADIUS configuration was changed intentionally, no action is required. If the RADIUS configuration was not changed intentionally, take appropriate action as defined by your enterprise security policy. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 780
configuration parameter was intentionally set to default values. If the password configuration parameter was intentionally set to default values, no action is required. If the password configuration parameter was not intentionally set to default values, take appropriate action as defined by your - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 781
SEC-3020 5 SEC-3020 Message Event: , Status: success, Info: Successful login attempt via . Message Type AUDIT Class SECURITY Severity INFO Probable Cause Indicates a successful login occurred. An IP address is displayed when the login occurs - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 782
automatically unlock after the lockout duration has expired or an administrator may manually unlock the account. SEC-3024 Message Event: , Status: success, Info: User account [], password changed. Message Type AUDIT Class SECURITY Severity INFO Probable Cause Indicates - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 783
SEC-3026 5 SEC-3026 Message Event: , Status: success, Info: User account [], role changed from [] to []. Message Type AUDIT Class SECURITY Severity INFO Probable Cause Indicates a user account role was changed. Recommended Action Verify - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 784
5 SEC-3029 SEC-3029 Message Event: , Status: success, Info: Backup user account \"\" recovered. Message Type AUDIT Class SECURITY Severity INFO Probable Cause Indicates that backup user accounts were recovered. Recommended Action Verify the security event was - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 785
SEC-3032 5 SEC-3032 Message Event: , Status: success, Info: Switch is configured to database. Message Type AUDIT Class SECURITY Severity INFO Probable Cause Indicates the specified event has occurred to - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 786
5 SEC-3035 SEC-3035 Message Event: ipfilter, Status: success, Info: ipfilter policy(ies) saved. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates the specified IP filter policies has been saved. Recommended Action Verify the security event was - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 787
was reported. The IP address of the unauthorized host is displayed in the message. Recommended Action Check for unauthorized access to the switch through the specified protocol connection. SEC-3044 Message The FIPS mode has been changed to . Message Type AUDIT Class SECURITY - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 788
5 SEC-3045 SEC-3045 Message Zeroization has been executed on the system. Message Type AUDIT Class SECURITY Severity INFO Probable Cause Indicates the system has been zeroized. Recommended Action Verify the security event was planned. If the security event was planned, no action is required. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 789
SEC-3048 5 SEC-3048 Message FIPS mode has been enabled in the system using force option. Message Type AUDIT Class SECURITY Severity INFO Probable Cause Indicates the system has been forced to Federal Information Processing Standards (FIPS) mode. Recommended Action Verify the security event - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 790
5 SEC-3051 SEC-3051 Message The license key is . Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that a license key is added or removed. Recommended Action No action is required. SEC-3061 Message Role '' is created. Message Type - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 791
SEC-3063 5 SEC-3063 Message Role '' is copied from ''. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates that the specified role name has been copied from the source role. Recommended Action No action is required. SEC-3064 Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 792
. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates the configuration of user-defined roles has been downloaded. Recommended Action No action is required. SEC-3067 Message Invalid Cipher list . Message Type AUDIT | LOG Class SECURITY Severity - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 793
SFLO-1001 5 SFLO Messages SFLO-1001 Message sFlow is globally. Message Type LOG Severity INFO Probable Cause Indicates that sFlow is globally enabled or disabled. Recommended Action No action is required. SFLO-1002 Message sFlow is for port . Message Type LOG - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 794
5 SFLO-1004 SFLO-1004 Message Global sFlow polling interval is changed to . Message Type LOG Severity INFO Probable Cause Indicates that the global counter sampling interval has been changed to the specified value. Recommended Action No action is required. SFLO-1005 Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 795
Recommended Action No action is required. SFLO-1008 Message All the sFlow collectors are unconfigured. Message Type LOG Severity INFO Probable Cause Indicates that none of the sFlow collectors are configured. Recommended Action No action is required. SFLO-1008 5 Fabric OS Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 796
LOG Severity ERROR Probable Cause Indicates that the Simple Network Management Protocol (SNMP) service could not be started because of the specified reason. Therefore, you will not be able to query the switch through SNMP. Recommended Action Verify that the IP address for the Ethernet and Fibre - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 797
Indicates that the SNMP configuration is incorrect and therefore the SNMP service will not work correctly. Recommended Action Change the SNMP configuration to the default using the snmpConfig --default command. SNMP-1005 Message SNMP configuration attribute, , has changed - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 798
5 SNMP-1009 SNMP-1009 Message Port traps are on port . Message Type AUDIT | LOG Class CFG Severity INFO Probable Cause Indicates the blocked or unblocked status of the port traps on the specified port. Recommended Action Execute the snmpTraps --show command to view the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 799
Action To recover a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade. To recover a non-bladed system, execute the fastboot command on the switch. Fabric OS Message Reference 777 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 800
5 SPC-2001 SPC-2001 Message S, : Crypto error asserted by Vader/OB1 0x. Message Type LOG Severity ERROR Probable Cause Indicates that Crypto error is asserted by the Field-Programmable Gate Array (FPGA). Recommended Action No - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 801
is required. SPC-2005 Message S, : FPGA firmware download success. Message Type LOG Severity INFO Probable Cause Indicates that FPGA download was successful. Recommended Action No action is required. SPC-2006 Message S - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 802
5 SPC-2007 SPC-2007 Message S, : Crypto post tests success: 0x. Message Type LOG Severity INFO Probable Cause Indicates that Crypto Power-On Self-Test (POST) has passed successfully. Recommended Action No action is required. SPC - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 803
SPC-2010 5 SPC-2010 Message S, : Crypto subsystem cover is open. Message Type LOG Severity CRITICAL Probable Cause Indicates that the Crypto subsystem cover is open. Recommended Action Close the Crypto subsystem cover properly. SPC- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 804
the system may be reduced. Contact the vendor for further instructions. SPC-2014 Message S, - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 805
SPC-2041 5 SPC-2041 Message S, : Alloc freemsg block failed. Message Type LOG Severity ERROR Probable Cause Indicates an allocation failure for the pool of SB message. Recommended Action No action is required. SPC-2042 Message S - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 806
5 SPC-2044 SPC-2044 Message S, : Read - device not open . Message Type LOG Severity WARNING Probable Cause Indicates that the SPD device is not opened. Recommended Action No action is required. SPC-3001 Message S< - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 807
input DEK format • 32 - DEK could not be unwrapped • 33 - FGPA error upon inject • 73 - Invalid key encryption key (KEK) format Recommended Action Contact your switch service provider for assistance. Fabric OS Message Reference 785 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 808
error upon inject • 73 - Invalid KEK format Recommended Action For status code 14, complete primary KEK generation; otherwise, contact your switch service provider. SPC-3007 Message S, : DEK create error: , info: - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 809
SPC-3008 5 SPC-3008 Message S, : SP crypto got READY notification. Message Type LOG Severity INFO Probable Cause Indicates that the key application (KPD) within the CryptoModule of the encryption engine has been started. Recommended - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 810
status code>. Message Type LOG Severity ERROR Probable Cause Indicates that the CryptoModule internal Secret Encryption Key could not be generated. Recommended Action Contact your switch service provider for assistance. 788 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 811
LOG Severity ERROR Probable Cause Indicates that the CryptoModule internal random number generator has failed. Recommended Action Contact your switch service provider for assistance. SPC-3015 Message S, : RSA pairwise key generation test - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 812
. Recommended Action Check the system resources and restart the switch. SPM-1002 Message Generic SPM Warning: . Message automatic FTP transfers; then execute the supportSave command and contact your switch service provider. SPM-1003 Message Set New Group Cfg SC Enable - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 813
SPM-1004 5 SPM-1004 Message Initialize Node. Message Type LOG Severity INFO Probable Cause Indicates a node initialization. Recommended Action No action is required. SPM-1005 Message Set EE Control slot action . Message Type LOG Severity INFO Probable Cause Indicates - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 814
5 SPM-1008 Recommended Action No action is required. SPM-1008 Message Dergistered SP Certificate in slot . Message Type LOG Severity INFO Probable Cause Indicates an security processor (SP) certificate de-registration. Recommended Action No action is required. SPM-1009 Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 815
out of sync. Message Type LOG Severity ERROR Probable Cause Indicates a failure to distribute security database. Recommended Action Execute the cryptocfg --sync -securitydb command to manually sync the security database. Fabric OS Message Reference 793 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 816
Type LOG Severity WARNING Probable Cause Indicates the master keys downloaded will not be effective unless imported because the encryption . Recommended Action Use the cryptocfg --sync -securitydb command to manually sync security database. SPM-1016 Message Security database is out of - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 817
SPM-3001 5 SPM-3001 Message Event: cryptocfg Status: success, Info: Node [] initialized. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates a node was initialized. Recommended Action No action is required. SPM-3002 Message Event: cryptocfg Status: - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 818
5 SPM-3004 SPM-3004 Message Event: cryptocfg Status: success, Info: EE in slot enabled. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates an encryption engine was enabled. Recommended Action No action is required. SPM-3005 Message Event: cryptocfg Status - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 819
SPM-3007 5 SPM-3007 Message Event: cryptocfg Status: success, Info: File imported via scp: []:. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates a file was imported through SCP protocol Recommended Action No action is required. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 820
5 SPM-3010 SPM-3010 Message Event: cryptocfg Status: success, Info: EE in slot zeroized. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates an encryption engine was zeroized. Recommended Action No action is required. SPM-3011 Message Event: cryptocfg - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 821
SPM-3013 5 SPM-3013 Message Event: cryptocfg Status: success, Info: Key vault with certificate label \"\" deregistered. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates a key vault was deregistered. Recommended Action No action is required. SPM- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 822
5 SPM-3016 SPM-3016 Message Event: cryptocfg Status: success, Info: Master key generated. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates a master key was generated Recommended Action No action is required. SPM-3017 Message Event: cryptocfg Status: success, - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 823
SPM-3019 5 SPM-3019 Message Event: cryptocfg Status: success, Info: System card registered. Certificate label: \"\" Certificate file: \"\". Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates a system card was registered. Recommended - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 824
5 SPM-3022 SPM-3022 Message Event: cryptocfg Status: success, Info: Authentication card with certificate label \"\" deregistered. Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates an authentication card was deregistered. Recommended Action No action - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 825
SPM-3025 5 SPM-3025 Message Event: cryptocfg Status: success, Info: File imported via USB: Source: Destination: . Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates a file was imported through a USB device. Recommended Action No - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 826
5 SPM-3028 SPM-3028 Message Event: SPM-EE state changed, Info: EE State: . Message Type AUDIT | LOG Class SECURITY Severity INFO Probable Cause Indicates an encryption engine state has changed. Recommended Action No action is required. SPM-3029 Message Event: KeyVault Connection - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 827
Execute the supportFtp command (as needed) to set the FTP or SCP parameters. After the problem is corrected, execute the supportSave command again. SS-1002 Message supportSave has stored support information to the USB storage device. Message Type LOG Severity INFO Probable Cause Indicates that - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 828
executed by the supportSave command. Recommended Action Execute the usbstorage command to check the USB storage device settings. After the USB problem is corrected, execute the supportSave command again. SS-1004 Message One or more modules timed out during supportsave. Retry supportsave with - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 829
Cause Indicates that there was no response from the blade in the specified slot for the given supportsave request. Recommended Action Restart the switch using the reboot command and then execute the supportSave command. SS-1008 Message supportsave failed for the slot . Reason: BP - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 830
WARNING Probable Cause Indicates that there is no Inter-Subsystem Communication (ISC) connection for the specified node slot. Recommended Action Restart the switch using the reboot command and then execute the supportSave command. SS-1010 Message CORE/FFDC files have been uploaded to the host - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 831
enough disk space in the secondary partition of the active CP to save the supportsave files, before uploading them to the remote host. Recommended Action Manually clean up the secondary partition of the active CP to collect the supportsave files. Fabric OS Message Reference 809 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 832
cycle the switch. SSMD-1002 Message Failed to initialize rc = . Message Type LOG Severity ERROR Probable Cause Indicates that the initialization of a module within System Services Manager (SSM) has failed. Recommended Action Download a new firmware using the firmwareDownload - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 833
an unexpected severe error during basic startup and initialization. Recommended Action Restart or power cycle the switch. If the problem persists, download a new firmware using the firmwareDownload command. SSMD-1006 Message Error while configuring ACL on interface - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 834
the Multicast Rate Limit feature. Recommended Action Delete and reapply the Quality of Service (QoS) Multicast Rate Limit policy using the qos rcv-queue multicast rate-limit command. If the problem persists, restart or power cycle the switch. 812 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 835
Action Delete and reapply the QoS Multicast Tail Drop policy using the qos rcv-queue multicast threshold command. If the problem persists, restart or power cycle the switch. SSMD-1202 Message QoS failed programming interface 0x 802.3x Pause flow control. Message Type LOG Severity - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 836
for enforcing the CEE Map Class of Service (CoS) to Priority Group ID (PGID) mapping feature. Recommended Action Delete and reapply the CEE Map CoS to PGID policy using the cee-map default command. If the problem persists, restart or power cycle the switch. 814 Fabric OS Message Reference 53 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 837
programming the dataplane ASIC for enforcing the interface Default CoS feature. Recommended Action Delete and reapply the QoS interface Default CoS policy using the qos cos command. If the problem persists, restart or power cycle the switch. SSMD-1208 Message QoS failed programming interface 0x - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 838
Delete and reapply the QoS interface CoS to Traffic Class policy using the qos cos-traffic-class command. If the problem persists, restart or power cycle the switch. SSMD-1211 Message QoS failed programming ASIC / Scheduler Control. Message Type LOG Severity - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 839
Action Delete and reapply the QoS CoS Tail Drop Threshold policy using the qos rcv-queue command. If the problem persists, restart or power cycle the switch. SSMD-1214 Message QoS failed programming interface 0x CoS Tail Drop Threshold. Message Type LOG Severity WARNING - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 840
for enforcing the interface Pause feature. Recommended Action Delete and reapply the QoS Pause policy. If the message persists, restart or power cycle the switch. SSMD-1217 Message QoS CEE could not comply with FCoE scheduler policy for CEE Map . Message Type LOG Severity WARNING - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 841
SSMD-1301 5 SSMD-1301 Message CEE Map is deleted. Message Type LOG Severity INFO Probable Cause Indicates that the specified CEE Map has been deleted. Recommended Action No action is required. SSMD-1302 Message CEE Map priority table are . Message Type - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 842
5 SSMD-1305 Recommended Action No action is required. SSMD-1305 Message CEE Map priority group weight is changed from to . Message Type LOG Severity INFO Probable Cause Indicates that the specified priority group weight has been changed. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 843
SSMD-1308 5 SSMD-1308 Message access list is deleted. Message Type LOG Severity INFO Probable Cause Indicates that the specified access list has been deleted. Recommended Action No action is required. SSMD-1309 Message access list rule sequence - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 844
5 SSMD-1312 Recommended Action No action is required. SSMD-1312 Message assigned to interface . Message Type LOG Severity INFO Probable Cause Indicates that the specified user profile map has been assigned to the interface. Recommended Action No action - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 845
Indicates that the specified CEE Map is incompatible with the current firmware and therefore it is reset to the default. Recommended Action No action is required. SSMD-1316 Message CEE Map is reset to default configuration. Message Type LOG Severity INFO Probable Cause Indicates that - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 846
5 SSMD-1318 SSMD-1318 Message ACL is being removed from interface . This operation could take a long time. Message Type LOG Severity INFO Probable Cause Indicates that the specified access list is being removed from the interface. Recommended Action No action is - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 847
Severity INFO Probable Cause Indicates that the firmwareDownload command has completed successfully and switch firmware has been updated. Recommended Action No action is required. The firmwareDownload command has completed as expected. Run the firmwareDownloadStatus command for more information - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 848
as expected. Run the firmwareDownloadStatus command for more information. SULB-1006 Message Forced failover succeeded. New Active CP is running new firmware. Message Type LOG Severity INFO Probable Cause Indicates that the previous standby control processor (CP) has now become the active CP - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 849
for completeness. TABLE 7 Status messages and status codes Status message Status code "Firmware download sanity check failed." "Sanity check failed because system is non-redundant." "Sanity check failed because firmware download is already in progress." "Sanity check failed because Fabric OS is - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 850
failed because HAMD is disabled on standby CP." "Firmware download failed on standby CP." "Firmware download failed on standby CP." "Firmware download failed on standby CP." "Firmware commit failed on standby CP." "Firmware download failed." "Firmware download failed due to IPC error." "Unable to - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 851
"Standby CP failed to boot up." 0x6f "Standby CP booted up with new firmware." 0x70 "Standby CP failed to boot up with new firmware." 0x71 "Firmware download has completed successfully on standby CP." 0x72 "Firmware download has started on standby CP. It might take up to 10 minutes. " 0x73 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 852
the required package list file. Check whether the switch is supported by the requested firmware. Also check the firmwareDownload help page for other possible failure reasons." 0x12 "The RPM package database is inconsistent. Contact your switch service provider for 0x13 recovery." 830 Fabric OS - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 853
old packages." 0x21 "Firmware download is already in progress." 0x22 "Firmware download timed out." 0x23 "Out of disk space." 0x24 "Primary filesystem is inconsistent. Run the firmwareRestore command to restore 0x25 the original firmware, or contact your switch service provider for recovery - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 854
RPM package." If this error occurs immediately after firmware download is started, the firmware on the switch may be two releases older than the requested firmware. The firmware download operation supports firmware upgrades within two feature releases (a feature release is indicated by a major - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 855
to the same version as the active CP. Then retry the firmwareDownload command to download the desired version of firmware onto the CPs. Refer to the Fabric OS Troubleshooting Guide for troubleshooting information. SULB-1010 Message Firmwarecommit failed (status=0x). Message Type AUDIT - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 856
slotPowerOff and slotPowerOn commands to trigger another firmware download. If the blade is stuck in the LOADING state, remove and re-insert the blade to trigger another firmware download. If the problem persists, contact your switch service provider. SULB-1018 Message Firmwaredownload timed out - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 857
the blade. If the blade is stuck in LOADING state, remove and re-insert the blade to trigger another firmware download. If the problem persists, contact your switch service provider. SULB-1021 Message Firmware is being downloaded to the blade in slot . Message Type AUDIT | LOG Class - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 858
inconsistent with the active CP firmware, firmware download will be restarted automatically on the blade. Run the firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your switch service provider. SULB-1024 Message Firmware commit has completed on the blade - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 859
of a firmware download. The error may also be caused by persistent storage hardware failure or by a software error. Recommended Action The firmwareDownload command will continue after the switch has rebooted. Run the firmwareDownloadStatus command to monitor progress. If the problem persists - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 860
Wait for the operation to complete. SULB-1032 Message Relocating an internal firmware image on the CP. Message Type AUDIT | LOG Class FIRMWARE Severity WARNING Probable Cause Indicates that the switch has started firmware download to the co-CPU. Recommended Action Wait for the operation to - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 861
If the problem persists, contact your switch service provider. SULB-1036 Message . Message Type LOG Severity INFO Probable Cause Indicates the version running in the system. This is generally logged before download and after download of the firmware to - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 862
, it will continue without updating the co-CPU firmware. Recommended Action After the firmware download completes, reboot the CP manually to bring up the co-CPU and run the firmwareDownload command again. If the problem persists, your switch service provider. SULB-1039 Message CP has completed - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 863
Message Firmwareactivate command has completed successfully. Message Type AUDIT | LOG Class FIRMWARE Severity INFO Probable Cause Indicates that the firmwareActivate command has completed successfully and the switch firmware has been updated. Recommended Action No action is required. The - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 864
the firmwareDownload command to the secondary partition has completed successfully and the switch will come up with the updated firmware on reboot. Recommended Action No action is required. The switch will auto-reboot with the downloaded firmware. 842 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 865
persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. SWCH-1002 Message Security violation: Unauthorized device tries to flogin to port . Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 866
standby control processor (CP) does not support N_Port ID Virtualization (NPIV) functionality, but the switch has some NPIV devices logged in to the fabric. Recommended Action Load a firmware version on a standby CP that supports NPIV functionality using the firmwareDownload command. 844 Fabric - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 867
Type LOG Severity WARNING Probable Cause Indicates that the switch port is disabled due to the reason displayed support port swap. Recommended Action Replace the blade with ports that support port swap. Then swap ports back to the port's default area. Refer to the Fabric OS Administrator's Guide - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 868
Administrator's Guide for more information. SWCH-1011 Message HA out of sync: Stby CP (ver=) doesn't support Trunk support Trunk Area functionality, but the switch has some ports with Trunk Area enabled. Recommended Action Load a firmware version on standby CP that supports - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 869
has been detected by the software. This is usually an internal Fabric OS problem or due to file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, execute the firmwareDownload command to update the firmware. Fabric OS Message Reference 847 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 870
not assigned to the device. Recommended Action This is an N_Port ID virtualization (NPIV) device and the static persistent PID is set on it, though the area port ID (PID) is set and static persistent PID is not supported on loop device. Recommended Action Remove the WWN-PID binding using the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 871
of service (QoS). Recommended Action Load a firmware version on the standby CP that supports QoS links to Access Gateway by using the firmwareDownload command. SWCH-1021 Message HA state out of sync: Standby CP (ver = ) does not support Dynamic area on default switch - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 872
Cause Indicates that the standby control processor (CP) does not support extended inter-switch link (XISL) while FICON Management Server (FMS) mode and Lossless are enabled. Recommended Action Load a firmware version on standby CP that supports both XISL use and FMS mode and Lossless at the same - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 873
the default switch and execute the configShow command. SWCH-1026 Message HA state out of sync: Standby CP (ver = ) does not support auto CP) does not support auto class-specific control (CS_CTL) mode. Recommended Action Upgrade the standby CP firmware version to same level - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 874
firmware or the nonvolatile storage may be corrupted. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. SYSC-1002 Message Switch to gather troubleshooting data. No - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 875
daemon is not restarted, either because a restart limit is reached or a restart action fails. Recommended Action Execute the supportSave command to gather troubleshooting data. Execute the reboot or haFailover command to recover the system. Fabric OS Message Reference 853 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 876
command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. SYSM-1002 Message , Switch: . Message Type LOG Severity INFO Probable Cause Indicates a user has executed either the switchShutdown or - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 877
SYSM-1004 5 SYSM-1004 Message Failed to retrieve current chassis configuration option, ret=. Message Type LOG Severity ERROR Probable Cause Indicates there was a failure to read configuration data from the World Wide Name (WWN) card. Recommended Action Verify that the WWN card is - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 878
5 SYSM-1007 SYSM-1007 Message PERMITTING USE OF INCOMPATIBLE CHASSIS FOR CP IN SLOT . DATA ERRORS MAY RESULT. Message Type LOG Severity WARNING Probable Cause Indicates an override of the incompatible control processor (CP) or chassis check. This message is for engineering use - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 879
TAPE-1001 5 TAPE Messages TAPE-1001 Message Key acquisition for . Message Type LOG Severity INFO Probable Cause Indicates that the key acquisition for the pool or the container has begun or is complete. Recommended Action No action is required. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 880
manually by issuing the tracedump -n command. • TRIGGER: Triggered by a specific Message ID generated by CRITICAL RASLog message. Recommended Action Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 881
Action Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. TRCE-1006 Message FTP Connectivity Test succeeded to FTP site ' '. Message Type LOG Severity INFO - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 882
persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. TRCE-1008 Message Unable to load trace parameters. Message Type FFDC | LOG Severity CRITICAL Probable Cause Indicates that the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 883
command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. TRCE-1011 Message Trace dump manually transferred to target ' ': . Message Type - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 884
WARNING Probable Cause Indicates that a trace dump has occurred on the switch or the specified slot, but the trace dump files were not automatically transferred from the switch because FIPS mode is enabled on the switch. Recommended Action No action is required. 862 Fabric OS Message Reference - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 885
a failed login. This occurs if the user name or password is entered incorrectly. Recommended Action Normally, this message indicates a occurs repeatedly, it may indicate an unauthorized user trying to gain access to a switch. When secure mode is enabled on the fabric, the IP address of a failed - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 886
Cause Indicates the track change feature recorded a configuration change for the switch. The track change feature records any change to the configuration file in nonvolatile memory, including a configuration download. This message is not generated for a configuration upload. All configuration - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 887
has the clock server IP configured correctly, and the configured clock server is accessible to the switch and functional. If the principal or primary FCS does not support the feature, either choose a different switch for the role or reset the clock server to LOCL. Fabric OS Message Reference 865 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 888
message can be one of the following: • Init failed. Time Service exiting - Initialization error, but the time server exits. • Synchronizing . For example, during fabric reconfiguration or role change of the primary FCS switch. If the message does not recur, it can be ignored. Recommended Action - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 889
Recommended Action No action is required. TS-1008 5 Fabric OS Message Reference 867 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 890
route detected: Port = , should be . Message Type FFDC | LOG Severity CRITICAL Probable Cause Indicates that the switch detected an inconsistency in the routing database between the routing protocol and the hardware configuration. The first port number displayed is what - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 891
. Message Type AUDIT | LOG Class CFG Severity INFO Probable Cause Indicates that in-order delivery (IOD) option has been disabled on the switch. This may cause out-of-order delivery of frames during fabric topology changes. Recommended Action No action is required. UCST-1023 Message Dynamic - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 892
. Message Type AUDIT | LOG Class CFG Severity INFO Probable Cause Indicates that Dynamic Load Sharing (DLS) option has been disabled on the switch. Recommended Action No action is required. UCST-1026 Message LossLess-DLS option has been enabled. Message Type AUDIT | LOG Class CFG Severity - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 893
in candidate list. Message Type LOG Severity WARNING Probable Cause Indicates that the switch is unreachable because no minimum cost path (MPATH) exists in the candidate Refer to the Fabric OS Administrator's Guide for more information on TI zoning. Fabric OS Message Reference 871 53-1002749- - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 894
5 VDR-2001 VDR Messages VDR-2001 Message . Message Type LOG Severity WARNING Probable Cause Indicates that the Field-Programmable Gate Array (FPGA) parity error threshold exceeded. Recommended Action Power cycle the switch. 872 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 895
for the device , port or (AG port - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 896
) feature has been enabled for the first time on the switch or the configuration file was corrupted or accidently removed. Recommended Action Creating a new default configuration file. Execute the configDownload command to download any of your earlier configurations for the virtual PWWN feature - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 897
daemon (vsd) startup because vsd has failed to register with Fabric OS State Synchronization (FSS). Recommended Action No action is required. VS-1008 Message Virtualization services failed to create timer. Message Type LOG Severity INFO Probable Cause Indicates failure in the virtualization - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 898
5 WEBD-1001 WEBD Messages WEBD-1001 Message Missing or Invalid Certificate file -- HTTPS is configured but could not be started. Message Type LOG Severity WARNING Probable Cause Indicates the Secure Sockets Layer (SSL) certificate file is either invalid or absent. Recommended Action Install - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 899
process will be restarted due to change of IP Address. Message Type LOG Severity INFO Probable Cause Indicates the IP address of the switch changed and the Hypertext Transfer Protocol (HTTP) server is restarted. Recommended Action No action is required. Fabric OS Message Reference 877 53 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 900
Probable Cause Indicates a rare error condition in which the built-in recovery process has failed to restore Hypertext Transfer Protocol (HTTP) services. The problem often results from invalid configuration of Secure Sockets Layer (SSL) certificates, but there can be more than one reason for such - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 901
SCSI write or read operation. Recommended Action If there was an unexpected job failure associated with this event, contact your vendor's customer support for assistance. XTUN-1001 Message FCIP Tunnel Memory allocation failed tracker - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 902
been aborted by the initiator. Recommended Action If there was an unexpected job failure associated with this event, contact your vendor's customer support for assistance. XTUN-1005 Message FCP emulation for Tunnel/Initiator/Target/LUN:// - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 903
, but the frame was dropped due to an invalid receive length. This error occurs only on faulty hardware. Recommended Action Contact your vendor's customer support for assistance. XTUN-1996 Message FTRACE buffer on slot DP has - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 904
event has been detected. Recommended Action If there was an unexpected job failure associated with this event, contact your vendor's customer support for assistance. XTUN-1998 Message FTRACE buffer has been cleared. Message Type LOG Severity INFO Probable Cause - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 905
XTUN-2000 5 XTUN-2000 Message FCIP Tunnel UP. Message Type LOG Severity INFO Probable Cause Indicates that the specified Fibre Channel over IP (FCIP) tunnel is up. Recommended Action No action is required. XTUN-2001 Message FCIP Tunnel - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 906
FCIP Tunnel -Pri QoS UP. Message Type LOG Severity INFO Probable Cause Indicates that the specified quality of service (QoS) for this tunnel is up. This applies to the data classes only. When the F-Class comes online, the tunnel itself is marked as - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 907
XTUN-2007 5 XTUN-2007 Message FCIP Tunnel Circuit CREATED (). Message Type LOG Severity INFO Probable Cause Indicates that the specified circuit has been successfully created. Recommended Action No action is required. XTUN-2008 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 908
5 XTUN-2011 Recommended Action No action is required. XTUN-2011 Message FIPS: . Message Type LOG Severity INFO Probable Cause Indicates that the status of the module FIPS compliance has changed. Recommended Action No action is required. XTUN-2020 Message FCIP Tunnel - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 909
XTUN-2022 5 XTUN-2022 Message FCIP Tunnel MODIFIED (). Message Type LOG Severity INFO Probable Cause Indicates that the specified Fibre Channel over IP (FCIP) tunnel has been administratively modified. Recommended Action No action is required. XTUN-2023 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 910
5 XTUN-2025 XTUN-2025 Message FCIP Tunnel Circuit MODATTR (). Message Type LOG Severity INFO Probable Cause Indicates that the attribute is modified. In most cases, the attribute value is modified within the specified - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 911
is not faulty. Replace the SFP transceivers or the cable if necessary. ZEUS-1002 Message Port chip faulted due to internal error. Message Type LOG | FFDC Severity ERROR Probable Cause Indicates an internal error. All ports on the blade or switch will be disrupted. Recommended - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 912
Probable Cause Indicates a memory allocation failure in the software. Recommended Action Restart the system at the next maintenance window. If the problem persists, replace the control processor (CP) blade. ZEUS-1015 Message Port re-initialized due to Link Reset failure on internal Port S - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 913
specified blade using the slotPowerOff and slotPowerOn commands. If the problem persists, replace the blade. ZEUS-1028 Message Detected excessive Link resets on the change the small form-factor pluggable (SFP) transceiver or cable on the peer port to which this port is connected. Fabric OS Message - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 914
(CAM) entries before the filter setup. Recommended Action If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. ZONE-1003 Message zone() contains ( - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 915
error when adding CAM entries before the filter setup. Recommended Action Avoid this problem in the following ways: • Avoid having too many hosts zoned with a the QuickLoop zoning configuration is enabled on the switch, it will not be supported. Recommended Action Edit the zone database to - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 916
there is any outstanding transaction running on the local switches. If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. 894 Fabric OS Message Reference 53-1002749-01 - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 917
side of the port is busy. Recommended Action If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. ZONE-1024 Message . Message Type LOG Severity - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 918
has exited. • Unknown: An error was received for an unknown reason. • User Command: A user aborted the current zoning transaction. • Switch Shutting Down: The switch is currently shutting down. Most of these error conditions are transitory. Recommended Action Try again after some time. Verify that - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 919
in the zoned core file directory. Recommended Action If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. ZONE-1034 Message A new zone database file is created - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 920
that the Fabric OS cannot examine the zone configuration file. Typically, the zone configuration is too large for the memory available on the switch. Recommended Action Reduce the size of the zone database and retry the operation. ZONE-1038 Message Unable to allocate memory for - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 921
configuration is too large for the memory available on the switch. Recommended Action Reduce the size of the zone database and cable. Recommended Action Verify that the small form-factor pluggable (SFP) transceiver and the cable at the specified port are not faulty. Replace the SFP and the cable - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 922
planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy. ZONE-1045 Message The Default Zone access mode is already set to No Access. Message Type LOG Severity INFO Probable Cause Indicates that the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 923
Zone access mode is already set to All Access. Message Type LOG Severity INFO Probable Cause Indicates that the Default Zone access mode is already set to All Access. Recommended Action No action is required. ZONE-1048 Message ZONE ACA is rejected on the standby. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 924
. Message Type LOG Severity WARNING Probable Cause Indicates that the Default Zone All Access mode will not grant all access behavior when switch with version pre6.4.0> running pre FOS6.4.0 firmware. TI member (Domain , Index ) is not supported. - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 925
specified domain causing non-TI and TI failover traffic disruption. Recommended Action Add or restore the non-TI or TI failover-enabled inter-switch links (ISLs) to the specified domain. ZONE-1061 Message Some trunk members are missing from failover disabled active TI zones. Message Type LOG - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 926
5 ZONE-1062 ZONE-1062 Message Defined and Effective zone configurations are inconsistent. Message Type LOG Severity WARNING Probable Cause Indicates that the defined and effective configurations are different. Recommended Action Execute the cfgEnable command to make both the configurations - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 927
ZONE-3003 5 ZONE-3003 Message Event: , Status: success, Info: \"\" deleted. Message Type AUDIT Class ZONE Severity INFO Probable Cause Indicates that the specified zone object has been deleted. The zone object type variable can be an alias, - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 928
5 ZONE-3006 Recommended Action Verify that the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy. ZONE-3006 Message Event: , Status: success, Info: Current zone - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 929
ZONE-3009 5 Recommended Action Verify that the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy. ZONE-3009 Message Event: , Status: success, Info: - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 930
5 ZONE-3012 ZONE-3012 Message Event: , Status: success, Info: Zone object \"\" renamed to \"\". Message Type AUDIT Class ZONE Severity INFO Probable Cause Indicates that the specified zone object has been renamed. Recommended Action Verify - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 931
ZONE-3015 5 ZONE-3015 Message Event: , Status: success, Info: AD configurations applied. Message Type AUDIT Class FABRIC Severity INFO Probable Cause Indicates that the saved Admin Domain (AD) configurations are enforced. Recommended Action Verify the event was planned. If the - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 932
5 ZONE-3018 ZONE-3018 Message Event: , Status: success, Info: has been deactivated. Message Type AUDIT Class FABRIC Severity INFO Probable Cause Indicates that the specified Admin Domain (AD) object has been deactivated. Recommended Action Verify - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 933
ZONE-3021 5 ZONE-3021 Message Event: , Status: success, Info: AD object \"\" renamed to \"\". Message Type AUDIT Class FABRIC Severity INFO Probable Cause Indicates that the specified Admin Domain (AD) has been renamed. Recommended Action - Dell PowerConnect Brocade M5424 | Brocade 7.1.0 Fabric OS Message Reference Guid - Page 934
with \"\". Message Type AUDIT Class ZONE Severity INFO Probable Cause Indicates that the specified zone object has been replaced. Recommended Action Verify that the event was planned. If the event was planned, no action is required. If the event was not planned, take
53-1002749-01
14 December 2012
®
Fabric OS
Message Reference
Supporting Fabric OS v7.1.0