Dell PowerEdge 2800 Information Update - Page 10

Presence, E07f0, Thermtrip, Missing, Status, Predictive, Ac Lost, Ac Range - support

Page 10 highlights

www.dell.com | support.dell.com Table 1-2. LCD Status Messages (continued) Line 1 Message E0780 E07F0 E07FA E0876 E0876 E0876 Line 2 Message Causes Corrective Actions PROC n PRESENCE Microprocessor is not installed in socket n. Install a microprocessor in socket n. See "Replacing a Processor" in your Installation and Troubleshooting Guide. PROC n IERR Faulty or improperly installed microprocessor. See "Troubleshooting the Microprocessors" in your Installation and Troubleshooting Guide. PROC n THERMTRIP Specified microprocessor is out of See "Troubleshooting System acceptable temperature range and Cooling Problems" in your has halted operation. Installation and Troubleshooting Guide. If the problem persists, ensure that the microprocessor heat sinks are properly installed. See "Replacing a Processor" in your Installation and Troubleshooting Guide. NOTE: The LCD continues to display this message until the system's power cord is disconnected and reconnected to the AC power source, or the SEL is cleared using either Server Assistant or the BMC Management Utility. See the Dell OpenManage Baseboard Management Controller User's Guide for information about these utilities. PS n MISSING PS n STATUS No power available from the specified power supply; specified power supply is improperly installed or faulty. See "Troubleshooting Redundant Power Supplies" in your Installation and Troubleshooting Guide. PS n PREDICTIVE Power supply voltage is out of See "Troubleshooting Redundant acceptable range; specified power Power Supplies" in your supply is improperly installed or Installation and Troubleshooting faulty. Guide. PS n AC LOST PS n AC RANGE Power source for specified power Check the AC power source supply is unavailable, or out of for the specified power supply. acceptable range. 8 Information Update

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

8
Information Update
www.dell.com | support.dell.com
E0780
PROC
n
PRESENCE
Microprocessor is not installed
in socket
n
.
Install a microprocessor in
socket
n
. See "Replacing a
Processor" in your
Installation
and Troubleshooting Guide
.
E07F0
PROC
n
IERR
Faulty or improperly installed
microprocessor.
See "Troubleshooting the
Microprocessors" in your
Installation and Troubleshooting
Guide
.
E07FA
PROC
n
THERMTRIP
Specified microprocessor is out of
acceptable temperature range and
has halted operation.
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide
. If the problem persists,
ensure that the microprocessor
heat sinks are properly installed.
See "Replacing a Processor"
in your
Installation and
Troubleshooting Guide
.
NOTE:
The LCD continues to
display this message until the
system’s power cord is
disconnected and reconnected to
the AC power source, or the SEL is
cleared using either Server
Assistant or the BMC Management
Utility. See the
Dell OpenManage
Baseboard Management
Controller User’s Guide
for
information about these utilities.
E0876
PS
n
MISSING
PS
n
STATUS
No power available from the
specified power supply; specified
power supply is improperly
installed or faulty.
See "Troubleshooting Redundant
Power Supplies" in your
Installation and Troubleshooting
Guide
.
E0876
PS
n
PREDICTIVE
Power supply voltage is out of
acceptable range; specified power
supply is improperly installed or
faulty.
See "Troubleshooting Redundant
Power Supplies" in your
Installation and Troubleshooting
Guide
.
E0876
PS
n
AC LOST
PS
n
AC RANGE
Power source for specified power
supply is unavailable, or out of
acceptable range.
Check the AC power source
for the specified power supply.
Table 1-2.
LCD Status Messages
(continued)
Line 1
Message
Line 2
Message
Causes