Dell PowerEdge 6400 Diagnostics Failure Message - Page 1

Dell PowerEdge 6400 Manual

Page 1 highlights

Dell Diagnostics, which is included on the Dell OpenManage Server Assistant CD and on your system utility partition, cannot test the PowerEdge Expandable RAID Controller 2/Dual Channel (PERC 2/DC) small computer system interface (SCSI) adapter. If your system contains one or more of these adapters with drives attached, you will receive the message Unknown target error when you run the diagnostics. The error message applies only to the PERC 2/DC SCSI adapter and can be ignored. The remainder of the diagnostics testing is not affected. When a permanent solution to this problem becomes available, Dell will post this information at http://support.dell.com. To avoid the error message when running the diagnostics, complete the following steps: 1. Boot to the utility partition and run the Dell Diagnostics. 2. Choose Select Devices to Test in the main menu of the Dell Diagnostics. 3. Select PERC 2/DC in the Device Groups window. 4. Highlight Select in the taskbar along the bottom of the screen and press . 5. Select One in the taskbar and press . 6. Press and select Run tests in the taskbar. 7. Highlight All in the taskbar and press . This runs all the diagnostics except the PERC 2/DC tests. To test the PERC 2/DC adapter(s), complete the following steps: 1. Boot to the Dell OpenManage Server Assistant CD. 2. Select SETUP from the taskbar at the top of the screen. 3. Choose Create Diskettes from the PowerEdge setup screen. www.dell.com P/N 232RY Rev. A00 April 2000 ™

  • 1
  • 2

±²³²´µ¶·±±
P/N 232RY Rev. A00
April 2000
www.dell.com
±²³³´µ¶·¸²¹º»¼²´µ½¾¿¿µÀÁ»µ
½¾Â¿µ±ÃÀ¼Á·ÄÅÃÆĵÇÀóȹ²µÉ²ÄÄÀ¼²
Dell Diagnostics, which is included on the
Dell OpenManage Server Assistant
CD and
on your system utility partition, cannot test the PowerEdge Expandable RAID Control-
ler 2/Dual Channel (PERC 2/DC) small computer system interface (SCSI) adapter. If
your system contains one or more of these adapters with drives attached, you will
receive the message
Unknown target error
when you run the diagnostics. The
error message applies only to the PERC 2/DC SCSI adapter and can be ignored. The
remainder of the diagnostics testing is not affected.
When a permanent solution to this problem becomes available, Dell will post this
information at
.
To avoid the error message when running the diagnostics, complete the following
steps:
1.
Boot to the utility partition and run the Dell Diagnostics.
2.
Choose
Select Devices to Test
in the main menu of the Dell Diagnostics.
3.
Select
PERC 2/DC
in the
Device Groups
window.
4.
Highlight
Select
in the taskbar along the bottom of the screen and press
<Enter>.
5.
Select
One
in the taskbar and press <Enter>.
6.
Press <Esc> and select
Run tests
in the taskbar.
7.
Highlight
All
in the taskbar and press <Enter>. This runs all the diagnostics
except the PERC 2/DC tests.
To test the PERC 2/DC adapter(s), complete the following steps:
1.
Boot to the
Dell OpenManage Server Assistant
CD.
2.
Select
SETUP
from the taskbar at the top of the screen.
3.
Choose
Create Diskettes
from the PowerEdge setup screen.