Dell PowerEdge 6950 Hardware Owner's Manual (PDF) - Page 25

Caution! NVRAM_CLR jumper, Error: Memory failure

Page 25 highlights

Table 1-8. System Messages (continued) Message Causes Corrective Actions Attempting to update Remote Configuration. Please wait... Remote Configuration request has Wait until the process is complete. been detected and is being processed. BIOS Update Attempt Failed! Remote BIOS update attempt failed. Retry the BIOS update. If problem persists, see "Getting Help" on page 129. Caution! NVRAM_CLR jumper NVRAM_CLR jumper is installed. is installed on system CMOS has been cleared. board. Remove the NVRAM_CLR jumper. See Figure 6-1 for jumper locations. Diskette drive n seek failure Incorrect configuration settings in the Run the System Setup program to System Setup program. correct the settings. See "Using the System Setup Program" on page 31. Faulty or improperly installed diskette Replace the diskette. If the problem drive. persists, see "Troubleshooting a Diskette Drive" on page 108. Loose diskette drive interface cable, or Reseat diskette drive interface cable, or loose power cable. power cable. See "Troubleshooting a Diskette Drive" on page 108. Diskette read failure Faulty or improperly inserted diskette. Replace the diskette. If the problem persists, see "Troubleshooting a Diskette Drive" on page 108. Diskette subsystem reset failed Faulty or improperly installed diskette. Replace the diskette. If the problem persists, see "Troubleshooting a Diskette Drive" on page 108. Drive not ready Diskette missing from or improperly inserted in diskette drive. Replace the diskette. If the problem persists, see "Troubleshooting a Diskette Drive" on page 108. Error: Memory failure detected. Memory size reduced. Replace the faulty DIMM as soon as possible. Faulty or improperly seated memory See "Troubleshooting System Memory" module(s). on page 106. Remote configuration update attempt failed System unable to process Remote Configuration request. Retry Remote Configuration. Fatal error caused a system reset: Please check the system event log for details. Fatal system error. Check the system event log for the specific cause, then see the appropriate section in"Troubleshooting Your System" on page 97. About Your System 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166

About Your System
25
Attempting to update
Remote Configuration.
Please wait...
Remote Configuration request has
been detected and is being processed.
Wait until the process is complete.
BIOS Update Attempt
Failed!
Remote BIOS update attempt failed.
Retry the BIOS update. If problem
persists, see "Getting Help" on page 129.
Caution! NVRAM_CLR jumper
is installed on system
board.
NVRAM_CLR jumper is installed.
CMOS has been cleared.
Remove the NVRAM_CLR jumper. See
Figure 6-1 for jumper locations.
Diskette drive
n
seek
failure
Incorrect configuration settings in the
System Setup program.
Run the System Setup program to
correct the settings. See "Using the
System Setup Program" on page 31.
Faulty or improperly installed diskette
drive.
Replace the diskette. If the problem
persists, see "Troubleshooting a Diskette
Drive" on page 108.
Loose diskette drive interface cable, or
loose power cable.
Reseat diskette drive interface cable, or
power cable. See "Troubleshooting a
Diskette Drive" on page 108.
Diskette read failure
Faulty or improperly inserted diskette.
Replace the diskette. If the problem
persists, see "Troubleshooting a Diskette
Drive" on page 108.
Diskette subsystem reset
failed
Faulty or improperly installed
diskette.
Replace the diskette. If the problem
persists, see "Troubleshooting a Diskette
Drive" on page 108.
Drive not ready
Diskette missing from or improperly
inserted in diskette drive.
Replace the diskette. If the problem
persists, see "Troubleshooting a Diskette
Drive" on page 108.
Error: Memory failure
detected. Memory size
reduced. Replace the
faulty DIMM as soon as
possible.
Faulty or improperly seated memory
module(s).
See "Troubleshooting System Memory"
on page 106.
Remote configuration
update attempt failed
System unable to process Remote
Configuration request.
Retry Remote Configuration.
Fatal error caused a
system reset: Please check
the system event log for
details.
Fatal system error.
Check the system event log for the
specific cause, then see the appropriate
section in"Troubleshooting Your System"
on page 97.
Table 1-8.
System Messages
(continued)
Message
Causes
Corrective Actions