Dell PowerEdge M420 Dell 10Gb Ethernet Pass Through II for M1000e Software Use - Page 16

Port Commands

Page 16 highlights

Rev 1.00 3.7 Port Commands Software User's Manual 3.7.1 show port link Synopsis: show port link [port_number] Description: This command displays detailed port information. If a front (uplink) port number is specified ([port_number]), then the command displays information only for this port; otherwise, the command displays information for all the ports. The command displays the following information per port: >Port number >Port group identifier: A or B >Pass through connection status, may have one of the following values: >down - either uplink or downlink is not connected >mismatch - both uplink and downlink are connected, but there is a mismatch >Downlink port link state: > down: Link disabled (no blade present) > 10G: 10GbE link >Detailed downlink port link states (available in ADMIN level only): >10G XAUI: 10G link with fixed parameters >Uplink port link state: >empty: No module present >module_type [no link]: Module is present (module type is shown); >no link: optical fiber cable is disconnected Example: # show port link Port Group Connect Downlink Uplink 1 A 10G 10G SFP+ SR 2 A 10G 10G SFP+ SR 3 A 10G 10G SFP+ LR 4 A 10G 10G SFP+ SR 5 A 10G 10G SFP+ SR 6 A mismatch 10G SFP SX 7 A down down SFP+ SR 8 A down down empty 9 B 10G 10G SFP SX 10 B 10G 10G SFP SX 16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

Software User’s Manual
Rev 1.00
16
3.7
Port Commands
3.7.1
show port link
Synopsis:
show port link [
port_number
]
Description:
This command displays detailed port information. If a front (uplink) port number is speci-
fied ([port_number]), then the command displays information only for this port; other-
wise, the command displays information for all the ports.
The command displays the following information per port:
>Port number
>Port group identifier: A or B
>Pass through connection status, may have one of the following values:
>down - either uplink or downlink is not connected
>mismatch - both uplink and downlink are connected, but there is a mismatch
>Downlink port link state:
>
down: Link disabled (no blade present)
>
10G: 10GbE link
>Detailed downlink port link states (available in ADMIN level only):
>10G XAUI: 10G link with fixed parameters
>Uplink port link state:
>empty: No module present
>module_type [no link]: Module is present (module type is shown);
>no link: optical fiber cable is disconnected
Example:
# show port link
Port
Group
Connect
Downlink
Uplink
----------------------------------------------------------
1
A
10G
10G
SFP+ SR
2
A
10G
10G
SFP+ SR
3
A
10G
10G
SFP+ LR
4
A
10G
10G
SFP+ SR
5
A
10G
10G
SFP+ SR
6
A
mismatch
10G
SFP SX
7
A
down
down
SFP+ SR
8
A
down
down
empty
9
B
10G
10G
SFP SX
10
B
10G
10G
SFP SX