Dell PowerEdge M820 Dell 10Gb Ethernet Pass Through II for M1000e Software Use - Page 6
LED Behavior
![]() |
View all Dell PowerEdge M820 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
Rev 1.00 Software User's Manual • Downlink (server blade) does not support the link protocol of the port group to which it is attached • Uplink (remote peer) does not support the link protocol of the port group to which it is attached The following drawing demonstrates link protocol mismatch conditions: Figure 2: Link Protocol Mismatch Examples 1.4 LED Behavior The LED behavior is described in the following table: Table 3 - LED Behavior Condition Link down Green LED Amber LED Description off off This condition occurs in the following cases: • Server blade not present, powered down, or link is inactive • Uplink port module not present • Uplink port cable not connected • One or both of the internal and/or external links is down 6
![](/manual_guide/products/dell-poweredge-m620-dell-10gb-ethernet-pass-ii-m1000e-software-users-manual-04c3a68/6.png)
Software User’s Manual
Rev 1.00
6
•
Downlink (server blade) does not support the link protocol of the port group to which it is
attached
•
Uplink (remote peer) does not support the link protocol of the port group to which it is attached
The following drawing demonstrates link protocol mismatch conditions:
Figure 2: Link Protocol Mismatch Examples
1.4
LED Behavior
The LED behavior is described in the following table:
Table 3 - LED Behavior
Condition
Green LED
Amber LED
Description
Link down
off
off
This condition occurs in the following cases:
•
Server blade not present, powered down, or link is
inactive
•
Uplink port module not present
•
Uplink port cable not connected
•
One or both of the internal and/or external links is
down