Dell PowerEdge MX740c EMC PowerEdge Servers Troubleshooting Guide - Page 24
PSA System board - RTC
View all Dell PowerEdge MX740c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
Table 13. PSA/ePSA error codes (continued) Error number (PSA and ePSA) Error message Description Steps Technical Support to resolve the problem. PSA 2000-0232 ePSA 2000-0232 (Not used with UEFI BIOS) System board - the RTC did not generate periodic ticks An error occurred during the 1. Update to the latest BIOS tests that may involve the main version. system board of the system. If a memory error is detected, try memory modules individually. If no 2000-0123 memory error & If 2. 3. Repeat the PSA diagnostics If failure continues, contact Dell Technical Support diagnostics fail again after the BIOS is current, contact Technical Support to resolve the problem. PSA 2000-0233 ePSA 2000-0233 (Not used with UEFI BIOS) PSA System board - RTC 'seconds' count is not updating ePSA RTC - 'seconds' count is not updating An error occurred during the 1. Update to the latest BIOS tests that involve the Real Time version. Clock (RTC) of the main system board in the system. If a memory error is detected, try memory modules individually. If 2. 3. Repeat the PSA diagnostics If failure continues, contact Dell Technical Support no 2000-0123 memory error & If diagnostics fail again after the BIOS is current, contact Technical Support to resolve the problem. PSA 1000-0234 ePSA 2000-0234 (Not used with UEFI BIOS) PSA System board - timeout waiting for RTC update flag to set ePSA System board - HPET incorrect time period. An error occurred during the 1. Update to the latest version. tests that may involve the main system board of the system. If a memory error is detected, try memory modules individually. If 2. 3. Repeat the PSA diagnostics If failure continues, contact Dell Technical Support no 2000-0123 memory error & If diagnostics fail again after the BIOS is current, contact Technical Support to resolve the problem. PSA 1000-0235 ePSA NA System board - PM timer 1 had wrong time period. An error occurred during the 1. Update to the latest BIOS tests that may involve the main version. system board of the system. If a memory error is detected, try memory modules individually. If no 2000-0123 memory error & If 2. 3. Repeat the PSA diagnostics If failure continues, contact Dell Technical Support diagnostics fail again after the BIOS is current, contact Technical Support to resolve the problem. PSA 1000-0241 BIOS - A20 gate not enabled ePSA 2000-0241 (Not used with UEFI BIOS) An error occurred during the 1. Update to the latest BIOS tests that may involve the main version. system board of the system. If a memory error is detected, try memory modules individually. If no 2000-0123 memory error & If 2. 3. Repeat the PSA diagnostics. If failure continues, contact Dell Technical Support diagnostics fail again after the BIOS is current, contact Technical Support to resolve the problem. PSA 1000-0242 PSA System board - no interrupt detected for IRQ. An error occurred during the 1. Update to the latest BIOS tests that may involve the main version. system board of the system. If a 24 Running diagnostics