Dell PowerEdge R510 Hardware Owner's Manual - Page 40
Mem mirror OFF, System Event - front cover
View all Dell PowerEdge R510 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 40 highlights
Code Text Causes Corrective Actions E2113 Mem mirror OFF on DIMM ## & ##. Power cycle AC The system BIOS has Remove AC power to the disabled memory system for 10 seconds and mirroring because it has restart the system. determined one half of the If the problem persists, mirror has had too many see "Troubleshooting errors. "## & ##" System Memory" on represents the page 177. memory-module pair implicated by the BIOS. I1910 Intrusion detected. Check chassis cover. System cover has been removed. Information only. I1912 System Event Log full. Review & clear log. The SEL is full of events Check the SEL for details and is unable to log any on the events, then clear more. the SEL. I1920 iDRAC6 Upgrade Optional iDRAC6 has Successful been upgraded successfully. Information only. W1228 RAID Controller battery capacity < 24hr. Warns predictively that the RAID battery has less than 24 hours of charge left. Allow RAID battery to charge to greater than 24 hours of sustained charge. If problem persists, replace RAID battery. See "Installing the RAID Battery" on page 147. W1627 Power required > PSU wattage. Check PSU and config. The system configuration requires more power than what the power supply can provide. Turn off power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system. 40 About Your System