Dell PowerEdge R510 Hardware Owner's Manual - Page 56
Warning: A fatal, Warning! No micro
View all Dell PowerEdge R510 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
Message Causes Corrective Actions Unused memory The memory configuration is Reconfigure the memory for detected. DIMM's not optimal for Advanced Advanced ECC Memory installed in the ECC Memory Mode. Mode, or change the following slot Modules in the specified memory mode to Optimized are not available slots are unused. or Sparing in the BIOS setup when in 128-bit screen. See "System advanced ECC Memory" on page 114. mode: x,x,x Warning: A fatal A fatal system error error has caused occurred and caused the system reset! system to reboot. Please check the system event log! Check the SEL for information that was logged during the error. See the applicable troubleshooting section in "Troubleshooting Your System" on page 169 for any faulty components specified in the SEL. Warning: Control Panel is not installed. The control panel is not Install the control panel, or installed or has a faulty cable check the cable connections connection. between the display module, the control panel board, and the system board. See "Integrated Storage Controller Card" on page 129. Warning! No micro Micro code update failed. code update loaded for processor n Update the BIOS firmware. See "Getting Help" on page 199. 56 About Your System