Back Cooling Fans, New LCD Error Codes - server

Page 2 highlights

Back Cooling Fans Systems manufactured after September 2008 no longer include the four back cooling fans installed in earlier systems. Therefore, BMC version 2.27 does not recognize the presence of back fans. The back fans will still run in older systems; however, from a system perspective, the fans do not exist and are not monitored. As a result, if the back fans fail, the SEL, server management software, and remote access card will not log the error. This change does not compromise the standard hot plug and redundancy features of the front fans. New LCD Error Codes The following LCD error codes have been added for your system. For a complete list of error codes, see "About Your System" in your Hardware Owner's Manual. Table 1. LCD Status Messages Code Test Causes EB107 Proc CPU detected an Machine unrecoverable hardware Check Error error. EB113 PCIE Fatal Error Slot XX CPU detected an unrecoverable hardware error. E1A18 PDB Ctrl Cable PDB control cable is missing, loose, or faulty. E1118 CPU Temp Interface Processor has exceeded acceptable temperature and has been disabled to prevent damage. Corrective Actions See error EB113 for specific information on what hardware failed. "XX" indicates the slot associated with the failed hardware. If you are unable to resolve the issue, see "Getting Help" in your Hardware Owner's Manual. Reseat the cable. If problem persists, replace the cable. See "Getting Help" in your Hardware Owner's Manual. See "Troubleshooting System Cooling" in your Hardware Owner's Manual.

  • 1
  • 2
  • 3
  • 4

Back Cooling Fans
Systems manufactured after September 2008 no longer include the four back
cooling fans installed in earlier systems. Therefore, BMC version 2.27 does not
recognize the presence of back fans. The back fans will still run in older systems;
however, from a system perspective, the fans do not exist and are not monitored.
As a result, if the back fans fail, the SEL, server management software, and
remote access card will not log the error. This change does not compromise the
standard hot plug and redundancy features of the front fans.
New LCD Error Codes
The following LCD error codes have been added for your system. For a complete
list of error codes, see "About Your System" in your
Hardware Owner’s Manual
.
Table 1.
LCD Status Messages
Code
Test
Causes
Corrective Actions
EB107 Proc
Machine
Check Error
CPU detected an
unrecoverable hardware
error.
See error EB113 for
specific information on
what hardware failed.
EB113 PCIE Fatal
Error Slot
XX
CPU detected an
unrecoverable hardware
error.
"XX" indicates the slot
associated with the failed
hardware. If you are unable
to resolve the issue,
see
"Getting Help" in your
Hardware Owner’s Manual
.
E1A18 PDB Ctrl
Cable
PDB control cable is
missing, loose, or
faulty
.
Reseat the cable. If
problem persists, replace
the cable. See
"Getting
Help" in your
Hardware
Owner’s Manual
.
E1118 CPU Temp
Interface
Processor has exceeded
acceptable temperature
and has been disabled to
prevent damage.
See "Troubleshooting
System Cooling" in your
Hardware Owner’s Manual.