Dell PowerVault DX6004S Dell DX6004S Hardware Owners Manual - Page 26

Check PSU., Power Supply

Page 26 highlights

Table 1-1. LCD Status Messages (continued) Code E1422 E1610 E1614 E1618 E161C E1620 Text Causes Corrective Actions CPU # machine check error. Power cycle AC. The system BIOS has reported a machine check error. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 161. Power Supply # Specified power supply See "Troubleshooting (### W) was removed or is missing Power Supply" on missing. from the system. page 143. Check power supply. Power Supply # Specified power supply (### W) error. has failed. Check power supply. See "Troubleshooting Power Supply" on page 143. Predictive An over-temperature See "Troubleshooting failure on condition or power supply Power Supply" on Power Supply # communication error has page 143. (### W). caused the predictive Check PSU. warning of an impending power supply failure. Power Supply # Specified power supply is (### W) lost attached to the system, AC power. but it has lost its Check PSU AC input. cables. Check the AC power source for the specified power supply. If the problem persists, see "Troubleshooting Power Supply" on page 143. Power Supply # Specified power supply's Check the AC power (### W) AC AC input is outside of the source for the specified power error. allowable range. power supply. If the Check PSU problem persists, see cables. "Troubleshooting Power Supply" on page 143. 26 About Your System

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168

26
About Your System
E1422
CPU # machine
check error.
Power
cycle AC.
The system BIOS has
reported a machine
check error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 161.
E1610
Power Supply #
(### W)
missing.
Check power
supply.
Specified power supply
was removed or is missing
from the system.
See "Troubleshooting
Power Supply" on
page 143.
E1614
Power Supply #
(### W) error.
Check power
supply.
Specified power supply
has failed.
See "Troubleshooting
Power Supply" on
page 143.
E1618 Predictive
failure on
Power Supply #
(### W).
Check PSU.
An over-temperature
condition or power supply
communication error has
caused the predictive
warning of an impending
power supply failure.
See "Troubleshooting
Power Supply" on
page 143.
E161C
Power Supply #
(### W) lost
AC power.
Check PSU
cables.
Specified power supply is
attached to the system,
but it has lost its
AC input.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supply" on page 143.
E1620
Power Supply #
(### W) AC
power error.
Check PSU
cables.
Specified power supply's
AC input is outside of the
allowable range.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supply" on page 143.
Table 1-1.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions