Dell PowerVault MD3660i Deployment Guide - Page 33
Appendix — Manual Configuration Of iSCSI
![]() |
View all Dell PowerVault MD3660i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
7 Appendix - Manual Configuration Of iSCSI The following sections contain step-by-step instructions for configuring iSCSI on your storage array. However, before beginning, it is important to understand where each of these steps occur in relation to your host server or storage array environment. The table below shows each iSCSI configuration step and where it occurs. This Step is Performed on the Host Server Using the Microsoft or Linux iSCSI Initiator This Step is Performed on the Storage Array Using PowerVault MD Storage Manager 1. Discover the storage array 2. Configure the iSCSI ports on the storage array 3. Perform target discovery from the iSCSI initiator 4. Configure host access 5. (Optional) Configure CHAP authentication on the storage array 6. (Optional) Configure CHAP authentication on the host server 7. Connect to the storage array from the host server 8. (Optional) Set up in-band management Step 1: Discover The Storage Array (Out-of-band Management Only) Default Management Port Settings By default, the storage array management ports are set to Dynamic Host Configuration Protocol (DHCP). If the controllers on your storage array are unable to get IP configuration from a DHCP server, it times out after 10 seconds and falls back to a default static IP address. The default IP configuration is: Controller 0: IP: 192.168.128.101 Subnet Mask: 255.255.255.0 Controller 1: IP: 192.168.128.102 Subnet Mask: 255.255.255.0 NOTE: No default gateway is set. NOTE: If DHCP is not used, initial configuration using the management station must be performed on the same physical subnet as the storage array. Additionally, during initial configuration, at least one network adapter must be configured on the same IP subnet as the storage array's default management port (192.168.128.101 or 192.168.128.102). After initial configuration (management ports are configured using PowerVault MD Storage Manager), the management station's IP address can be changed back to its previous settings. NOTE: This procedure applies to out-of-band management only. If you choose to set up in-band management, you must complete this step and then see Step 8: (Optional) Set Up In-Band Management. 33
![](/manual_guide/products/dell-powervault-md3660i-deployment-guide-12c5efa/33.png)