Dell PowerVault ML6000 Dell PowerVault ML6000 SMI-S Reference Guide - Page 68
Description/Notes, Required Server Level Instances of ChangerDevice
View all Dell PowerVault ML6000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 68 highlights
Table 59 Required Server Level Instances of ChangerDevice Property SystemCreationClassName[key] Physical Library Instance 1 "CIM_ComputerSystem" Partition Instances (one for each partition) "CIM_ComputerSystem" SystemName[key] CreationClassName[key] DeviceID[key] MediaFlipSupported ElementName OperationalStatus[valuemap] Caption Description Availability[valuemap] "CIM_Computersystem" "CIM_Computersystem" "::" False False "SMIS_ChangerDevice" "SMIS_ChangerDevice" Robotics RAS status {OK(2)} Physical Library Library name (library_a or library_b, etc.) Physical Medium Changer "Partition " Running/Full Power(3) or Running/Full Power(3) or Offline Offline (8) (8) Table 60 Required Properties for ProtocolControllerForUnit Property Antecedent Dependent DeviceNumber Type REF REF string Description/Notes The ProtocolController. The controlled device. Address of associated device in context of the antecedent ProtocolController. Formatted as unseparated uppercase hexadecimal digits, with no leading "0x". Table 61 Required Server Level Instances of ProtocolControllerForUnit Property Antecedent Dependent DeviceNumber Drive Instances (one for each direct-attached drive) Changer Instance (one for each changer which has a control-path drive) CIM_SCSIProtocolController (corresponding to the drive) CIM_SCSIProtocolController (corresponding to control path drive) CIM_TapeDrive CIM_ChangerDevice "0" "1" 64 SMI-S Common Protocol Interface Specification