Dell PowerVault ML6000 Dell PowerVault ML6000 SMI-S Reference Guide - Page 83

Required Blade Instances of SCSIProtocolController LUN Mapping Disabled

Page 83 highlights

Table 103 Required Blade Instances of FCPort Property SystemCreationClassName[key] SystemName[key] CreationClassName[key] DeviceID[key] PortNumber PermanentAddress ElementName OperationalStatus NetworkAddress PortType ActiveFC4Types OtherNetworkPortType LinkTechnology OtherLinkTechnology ActiveCOS UsageRestriction Blade Instances (one for each blade target FC port) "CIM_ComputerSystem" "SMIS_FCPort" "B::::WWN" Example: 1 WW Port Name Format is 16 octets 1234567887654321 "CIM_FCPort" Port Status. Example: ok(2) 0 Example: N(10) SCSI-FCP(8) "" since portType is N(10) FC(4) "" 3 Front-end only(2) Table 104 Required Blade Instances of SCSIProtocolController (LUN Mapping Disabled) When LUN Mapping is disabled, the blade has a SCSIProtocolController representing each zone on the blade, and since zoning is tied to target ports, this ties the blade SPC object to a blade target port. Property SystemCreationClassName[key] SystemName[key] CreationClassName[key] DeviceID[key] OtherIdentifyingInfo Caption Description ElementName IdentifyingInfoDescriptions Instances (one for each port on a Fibre Channel I/O blade) CIM_ComputerSystem CIM_SCSIProtocolController "B"::. {blade serial} "B"::. "FC Blade , port " CIM_SCSIProtocolController {"Serial Number"} Dell PowerVault ML6000 SMI-S Reference Guide 79

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94

Dell PowerVault ML6000 SMI-S Reference Guide
79
Table 103
Required Blade Instances of FCPort
Table 104
Required Blade Instances of SCSIProtocolController (LUN Mapping Disabled)
When LUN Mapping is disabled, the blade has a SCSIProtocolController representing each zone on the
blade, and since zoning is tied to target ports, this ties the blade SPC object to a blade target port.
Property
Blade Instances (one for each blade target FC port)
SystemCreationClassName[key]
“CIM_ComputerSystem”
SystemName[key]
<HID>
CreationClassName[key]
“SMIS_FCPort”
DeviceID[key]
"B:<bladeID>:<portID>:<location>:WWN”
PortNumber
Example: 1
PermanentAddress
WW Port Name Format is 16 octets 1234567887654321
ElementName
"CIM_FCPort”
OperationalStatus
Port Status. Example: ok(2)
NetworkAddress
0
PortType
Example: N(10)
ActiveFC4Types
SCSI-FCP(8)
OtherNetworkPortType
“” since portType is N(10)
LinkTechnology
FC(4)
OtherLinkTechnology
“”
ActiveCOS
3
UsageRestriction
Front-end only(2)
Property
Instances (one for each port on a Fibre Channel I/O
blade)
SystemCreationClassName[key]
CIM_ComputerSystem
SystemName[key]
<Vid> <Pid> <Serial>
CreationClassName[key]
CIM_SCSIProtocolController
DeviceID[key]
“B”:<bladeIP>:.<port>
OtherIdentifyingInfo
{blade serial}
Caption
“B”:<bladeIP>:.<port>
Description
“FC Blade <IP>, port <port>”
ElementName
CIM_SCSIProtocolController
IdentifyingInfoDescriptions
{“Serial Number”}