Dell Precision R7600 Dell Precision Workstation R7610 Owner's Manual - Page 108

Errors That Do Not Halt the System, Plug & Play Configuration Error

Page 108 highlights

• Alert! Chipset heat sink not detected. • Alert! Operating in debug mode. Please populate memory in pairs for normal operation. • Alert! Power supply fan failure. • Alert! Previous fan failure. • Alert! Previous processor thermal failure. • Alert! Previous reboot was due to voltage regulator failure. • Alert! Previous shutdown due to thermal event. • Alert! Previous voltage failure. • Alert! System battery voltage is low. • Alert! Uncorrectable memory error previously detected at XXXXXXXXh • Alert! Unable to initialize fan controller. • Plug & Play Configuration Error Errors That Do Not Halt the System The following is a list of BIOS error messages that do not halt the system but will display a warning message, pause for a few seconds, and then continue to boot: • Alert! Cover was previously removed • Alert! Error initializing PCI Express slot n (or bridge) 108

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123

Alert! Chipset heat sink not detected.
Alert! Operating in debug mode. Please populate memory in pairs for normal operation.
Alert! Power supply fan failure.
Alert! Previous fan failure.
Alert! Previous processor thermal failure.
Alert! Previous reboot was due to voltage regulator failure.
Alert! Previous shutdown due to thermal event.
Alert! Previous voltage failure.
Alert! System battery voltage is low.
Alert! Uncorrectable memory error previously detected at XXXXXXXXh
Alert! Unable to initialize fan controller.
Plug & Play Configuration Error
Errors That Do Not Halt the System
The following is a list of BIOS error messages that do not halt the system but will display a warning message, pause for a
few seconds, and then continue to boot:
Alert! Cover was previously removed
Alert! Error initializing PCI Express slot n (or bridge)
108